GS3055-I Installation Process

Slides:



Advertisements
Similar presentations
Aspire Vertical Markets Law Office. Law Office Solutions.
Advertisements

Aspire Vertical Markets Executive Suite Solution.
Aspire Vertical Markets Retail Store. Retail Store Solution.
Follow the instruction to install the PC Suite from the SD card: 1.Go to the settings -> SD Card & phone storage -> Enable the mass storage only mode 2.Connect.
Alarm transmission over IP networks
2014 Redrock Software Conference ADV – Advanced Preferences and Settings By Jonathan Smith.
INTRUSION ALARM TECHNOLOGY
GPC VOIC MODULAR MESSAGING 3.0.
SCW9057 Key Features/Benefits
Welcome to the Radionet Monitoring Secure-Com Presentation.
ARC reporting ARC Cerny Verze
2N Lift Easy Talk Guaranteed safety. Compulsory lift equipment Cabin light Cage door Two-way communication device Breaking system Norm: EN
1 Telephone Connection. 2 Introduction The section instructs you on how to install a required phone line to every receiver.
Thank you for choosing HUAWEI E560 Wireless Modem (hereinafter referred to as the E5). z The supported functions and actual appearance are subject.
Copyright © Open Text Corporation. All rights reserved. Slide 1 Automatic Routing With Captaris FaxPress and FaxPress Premier Darin McGinnes Sales Engineer.
Smart Personal Console (SPC). Smart Personal Console Overview SPC allows users more control over their personal communications settings. Users can view/set:
OfficeTrack Mobile Employees Location Management Service.
OfficeTrack Mobile Employees Location Management Solution.
Tecom IP Receiver. Overview The Tecom IP Receiver is a server which provides a cost-effective and secure method to monitor Challenger panels over IP networks.
Sur-Gard System III Receiver
Nokia 30 technical specification
Summary Summary This slides is for information Purposses on
Orion Telecom Networks Inc VCL-E1 DACS 8 Port, E1 Digital Access Cross Connect Switch Slide 1 Updated : January 1st, , Avenue of Fountains,
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
1 RISCO Agility, PIR Cam & Cloud Combined Presentation.
1 Business Communication Systems (BCS) EXP1240 Series IP DECT Cordless System for Mobility EXP1240 Series.
Sur-Gard System III Receiver
GS3055-I GSM Universal Wireless Alarm Communicator
KX-NS1000 Initial Set Up For step by step : 16 May,
The Comfort System Product Presentation The Intelligent Home System.
© 2001 National Burglar & Fire Alarm Association Chapter 10 The Central Station –24 hour /7day Operation –Receive Signals –Process Signals –React.
IP Telephony Phase II Rollout OIT ComTech. Outline Why are we meeting? Roadmap Centrex vs Call Manager What happens now ? Deployment objectives Phone.
Understanding Eligible Services I 2013 Schools and Libraries Fall Applicant Trainings 1 E-rate Program Understanding Eligible Services.
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
SERVICE LEVEL AGREEMENTS Bob Goldberg 312/
Tapit Call Accounting software for the 21st Century Copyright Trisys, Inc Trisys, Inc 215 Ridgedale Avenue Florham Park, NJ (973)
GS2065/TL265GS Product Technical Training (International version)
GSM Communication The Future of Alarm Communication
GS2060/TL260GS Product Technical Training
Onfer III TM COMMUNICATIONS INTERNATIONAL Private Branch Exchange (PBX) or Central Office (CO) Your Phone analog 2-wire line Call setup phase: 1.Your phone.
AVS Audio Verification System
© 2008 Cisco Systems, Inc. All rights reserved.CIPT1 v6.0—2-1 Administering Cisco Unified Communications Manager Understanding Cisco Unified Communications.
December 2013 – Alexandre TRIFFAULT Alarm system Inspired by Babak Javadi presentation.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
FUNCTIONALITIES MYLINE is an interface able to simulating a standard PSTN telephone socket using the GSM network. It is therefore possible to reproduce.
C24 Dealer Portal Application Rev 100. Administration Application Support Tool to configure, control, and support your customer’s systems
Cintas Fire Protection
Power Series Basic Programming NTS# Agenda DSC PowerSeries Basic Programming Course Length 4 hrs Course Overview(5 Min).At the conclusion of.
Health Insurance Portability and Accountability Act of 1996 (HIPAA) Proposed Rule: Security and Electronic Signature Standards.
RSG (Remote Service Gateway). 1. Overview  Overview The LDK-RSG (LDK-Remote Services Gateway) is a remote gateway that provides a fully transparent connection.
Mobilink ISDN Digital Fixed Cellular Terminal. TOPEX MOBILINK ISDN 2G Terminal for voice that can connect one PBX with ISDN-BRI ports or an ISDN telephone.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Paradox Communication Solution GPRS / GSM
SMS Module Model : SB-DN-SMS/IP Configuration of SMS Module.
GS3055-I Installation Process
INTRUSION ALARM TECHNOLOGY
Confer III- Flex Confer III Flex “Dynamic Port Allocation” Audio Conferencing Bridge Confer III FLEX Dynamic Port Allocation 1223 North Glenville Dr. Richardson,
1 Chapter Overview Modems The Internet and Web Browsers.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Rohde & Schwarz Topex TOPEX IP Radio Gateway July 2011.
Run the on your PC to start the firmware configuration process Run IP Config Tool.
Commercial Card Expense Reporting (CCER) The Trustees of Roanoke College An internet solution Accessed via Wells Fargo’s secure Commercial Electronic Office.
GSM FCT for Emergency Applications
S4 Combo Secual Product Training March 2016.
SMS module HDL-MGSM.431.
Universal connection and monitoring for M2M applications
Advisor Advanced Release FW120.
The Hong Kong University of Science and Technology
Presentation transcript:

GS3055-I Installation Process

GS3055-I Overview The GS3055-I is: A universal wireless alarm communicator that can be used as a backup or primary communicator A device which connects the alarm control panel to the GSM network and reports alarm signals directly to a monitoring central station receiver (Sur-Gard System III with a DRL3-IP line card or System II) A digital transmitter which provides full reporting from any control panel that communicates using Contact ID format

GS3055-I Service Provider Who is CONNECT 24? CONNECT 24 is the GS3055-I service provider CONNECT 24 provides the automated telephone activation system for the activation of GS3055-I units (GVRU, Voice Response Unit) CONNECT 24 provides the web-user interface support for the programming of GS3055-I units (future use) CONNECT 24 provides account administration, billing and rate plans to GS3055-I customers

GS3055-I Enrolment Steps In order to properly enrol a GS3055-I unit you must follow these steps: Important Note: Prior to installing a GS3055-I you must first become an authorized dealer. Please consult your central monitoring station for master reseller programs or visit www.connect24.com and complete the authorization form STEP 1 – Activate your SIM card with Connect 24* STEP 2 – Initialize the GS3055-I with Connect 24* STEP 3 – Determine best signal strength location STEP 4 - Connect the GS3055-I to the control panel STEP 5 - Program the control panel to use the GS3055-I STEP 6 – Test the GS3055-I * Note: GS3055-I unit must be powered down for STEPS 1 and 2

GS3055-I SIM Card Activation (GVRU) Prior to installation, each SIM Card must be activated via the Connect 24 GVRU (1-866-910-3865, option [6]). Activations must be performed at least 24 hours before to installation (initialization) The following information is required when activating a SIM Card: Installer’s ID Number: Identifies each installer listed on the Dealer Enrolment Form Installer’s PIN Number: Identifies each installer with a 4 digit PIN number The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card Note: Only authorized dealers can activate a SIM Card with CONNECT 24

GS3055-I Initialization (GVRU) GS3055-I initializations can be performed via the Connect 24 GVRU (1-866-910-3865, option [4]) Enter the following information and options when initializing a unit: Profile Number: Represents the Central Station Receiver IP address and Rate Plan Installer’s ID Number: Identifies the installer listed on the Dealer Enrolment Form Installer’s PIN Number: Identifies the installer The Central Station Account Number: Represents the account number that will be transmitted to the Central Station Receiver The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card The DNIS Number: (Dialled Number Information Service), Check with your Central Station 7. Test transmission selection: select the required test schedule (no test, daily, weekly or monthly) Determine if GS3055-I unit is the primary or backup communicator: enable/disable TLM (telephone line monitor) option Note: Only authorized dealers can activate a SIM Card with CONNECT 24

GS3055-I Signal Strength Test To test the signal strength of a GS3055-I: Connect the antenna to the GS3055-I Ensure that the SIM card is installed into the GS3055-I Connect the battery to the GS3055-I Signal strength levels: LED#3 and LED#4 ON = Excellent Signal Strength LED#4 ON = Good Strength LED#4 Flashing = Poor Signal Strength Both OFF = No signal Strength Note: For proper installation, a GS3055-I must have Good or Excellent Signal Strength. If a poor strength is detected, the unit should be relocated or an antenna extension should be used LED# 3 LED #4

GS3055-I – Telephone Wiring (Back-up Mode) To Power Supply From RJ-31X Demarcation To Premise Telephones

GS3055-I Control Panel Programming The following control panel programming is required : Telephone number * Account number Communications format – Contact ID Reporting codes or select automatic reporting** Communications enabled *If communicating only using the GS3055-I (no land-line), program any telephone number **If supported by the control panel

GS3055-I Testing To test the GS3055-I, perform the following: Disconnect the telephone line from the TIP and RING terminals on the GS3055-I Wait for LED 2 (YELLOW) to turn ON (indicates that the unit is in GSM mode) Force the control panel to transmit a signal (i.e. zone alarm, keypad alarm etc.) Connect a handset to RING and TIP on the control panel to verify that the control panel is communicating

GS3055-I – Testing Diagram To Power Supply Connect the 12V/1.2AH Battery to the GS3055-I To Premise Telephones

GS3055-I Assistance Directory Connect 24 Phone Number: 1-888-955-5583 (Canada) 1-888-251-7458 (US) Fax: 1-877-224-3676 Website: www.connect24.com E-mail: customerservice@connect24.com GVRU Activation and Initialization: 1-866-910-3865 DSC Technical Support Phone Number: 1-800-387-3630 E-mail: tech@dsc.com Website: www.dsc.com

GS3055-I Questions?