Pre-Engineered Water Surface Water Treatment Plants

Slides:



Advertisements
Similar presentations
Arsenic/Iron Co-Precipitation and High Rate Filtration in the City of Portage Christopher Barnes, P.E., City of Portage Kendra Gwin, P.E., City of Portage.
Advertisements

Overview of Water Treatment
Eco Pond Rescues WaterWagon Demonstration at Reedy Creek Environmental District November 11, 2010.
DAF Whitewater Systems
North Texas Municipal Water District Water Treatment Process.
CE 370 Sedimentation.
Zelienople Water Department Sources and Treatment.
CLARIFIERS Prepared By Michigan Department of Environmental Quality
Treatment of Slaughterhouse Wastewater
American Water Raw Water Quality Not Textbook? Just Pilot! Iron Removal with High pH Raw Water March 27, 2008 Sandy Kutzing, P.E., CDM Eric Hahn, P.E.,
Filtration by Douglas Rittmann, Ph.D., P.E.
CE 370 Filtration.
USG Drinking Water Treatment System for high turbid water source.
Coagulation and Flocculation at Water Treatment Plants
Benjamin C. Whitehead, PE Benjamin J. Klayman, PhD, PE Case Study: Commissioning New Rapid Sand Filters at Donald K. Shine Water Treatment Plant.
Surface Water Treatment Plant
ETL Multi Media Grey Water Filters and Pre Reverse Osmosis Filtration.
Filter manifold Holding tank Iron- manganese filter Aeration tank Control unit Pre- filter To storage tanks Backwash overflow SO2 vent Bypass Cutoff valve.
20,000 Barrel Per Day Produced Water Treatment System
Improvement of the Capacity of Drinking Water Treatment Plant in East Quantara (Case Study) Dr. Eng. Ibrahim Khaled El-Sayed Chairman 1North & South Sinai.
AQUATEST a.s. TECHNICAL SUPPORT DIVISION Modular units for mine water disposal A set of technical equipment designed for mine water disposal is.
Willamette Water Treatment Plant
Direct Cross-Connection (a) A Clean-In-Place system is used to direct sanitizer from a reservoir to a recently cleaned milk tank. The sanitizer exists.
Molalla Water Treatment Plant Field Trip 4/24/07 Molalla Water Treatment Plant Field Trip 4/24/07.
History In 1932 Plymouth constructed its first wastewater treatment plant In 1959 they transferred the sewage utilities over to Plymouth Utilities.
Surface Water Treatment Plant. Fig 4-8: Flow Diagram of conventional surface water treatment plant (“filtration plant”)
City of Atlanta Department of Watershed Management Bureau of Drinking Water.
Introduction to Environmental Engineering Code No. (PE389) Lec. 5 and 6.
BCE Environmental Engineering Water Treatment Mdm Nur Syazwani binti Noor Rodi.
Water Treatment CE 326 Principles of Environmental Engineering Department of Civil, Construction and Environmental Engineering Iowa State University March.
CTC 450 Review Water Quality Water Distribution Systems.
Water Treatment Processes. Why do we need to treat our drinking water?  Industrial runoff  Agricultural runoff  Road runoff  Residential runoff.
| Vigyan Ashram | INDUSA PTI |. In this presentation you will learn: – Basic terminologies used in grey water treatment | Vigyan Ashram | INDUSA PTI |
4.4 WATER POLLUTION.
Processing, distribution and use of water.
The Drinking Water Treatment Process
Water in the Community: From Lake Ontario to us Thursday, March 25 th.
E NVIRONMENTAL E NGINEERING 441 Lecture 5: Water Treatment (3) Sedimentation & filtration Philadelphia University Faculty of Engineering Department of.
 Watch the Peel Water Treatment Tours › Water Treatment Plant Tours Water Treatment Plant Tours  Complete the reading on Peel’s Water Treatment Process.
Water Treatment Plant Austin and Alison.
Date: Monday, May 11 th 2015 Topic: Water Purification Objective: To recognize the stages of it.
IAFNR Module 4 Natural Resources
Water and Wastewater Treatment
Assignment You need to draw and label each step of the water treatment process Under each label explain what is happening in that step.
Engineered systems for wastewater treatment and disposal.
Membrane Bioreactors for Wastewater Treatment.
 Asia’s largest environment solutions provider, with a strong international presence  Total water & environment management solutions for all sectors.
What Is In This Chapter? Water Treatment Overview
Safe, Clean and Drinkable
Steel Filters.
How Water Flows Through the Plant
Warm Up p65 Which part of the water cycle is MOST responsible for polluting surface water? Municipalities (towns) get drinking water from which two sources?
Lecture 6: Wastewater treatment
テンプレート:A0 ページ設定※ 幅 84.1cm 高さ 118.9cm
High-Rate Clarifier / Thickener
Water Treatment.
Microfloc Products Adsorption Clarifier/Trident/Tri-Mite
Warm Up p65 Which part of the water cycle is MOST responsible for polluting surface water? Municipalities (towns) get drinking water from which two sources?
Filtration Technologies Comparison for Tertiary Treatment
Experience Nordic Water WesTech / General Filter
Lecture # 11 Water treatment:.
Vertical Pressure Filters
Enhancing Rapid Sand Filtration by Backwashing with Alum
CTC 450 Review Water Quality Water Distribution Systems.
Microfloc Products Adsorption Clarifier/Trident/Tri-Mite
Treatment – Sediment Filters
Water Treatment.
3.1Process selection and the treatment process train
Physical/Chemical Waste Treatment
Skid Mounted Water Treatment Plant
Presentation transcript:

Pre-Engineered Water Surface Water Treatment Plants MICROFLOC® Products WaterBoy™ & Aquarius®

Topics Discussed Equipment Design Features Application Areas

WaterBoy Flow Diagram

WaterBoy Features Coagulation, flocculation, 7 1/2° tube settling and mixed media filtration Completely pre-assembled single tank units in sizes up to 60 gpm Standard sizes WB-14, 27, 82 and 133A Standard flows 10, 20, 60 and 100 gpm Clarification based on equivalent settling surface area of 100 gpm / ft2 Detention time in flocculator - 10 minutes

Microfloc WaterBoy™

WaterBoy Process Operation Backwash Flow set with influent valve or float Filter level float valve Chemicals added upstream of tank Flash mix and one flocculation stage Flow up through tubes and down through filter Water pumped to storage Filter headloss starts backwash (vacuum) Drain siphon primed Tubes siphon drained Backwash pumped through filters and tubes Drain siphon broken Tubes filled with clean backwash and placed back in operation

WaterBoy Application For water temperature above 50° F Up to 200 NTU Up to 100 true color Up to 10 mg / L iron Up to 5 mg / L manganese For water temperature below 50° F, reduce above criteria by up to 50 % Higher solids loading than Tri-Mite Lower solids loading than Aquarius

WaterBoy Sweet Spots Treats surface and ground waters Size permits portable installations on skids and trailers Ideally suited for small communities, low flow industrial applications, resorts and recreational sites Over 300 installations

Microfloc Aquarius®

Aquarius Flow Diagram

Aquarius Features Coagulation, two stage flocculation, 7 1/2° tube settling and mixed media filtration Two tank system shipped loose Standard sizes AQ-70B, 112B, 150B & 300B Available in 350, 520, 700 and 1400 gpm Clarification based on equivalent settling surface area of 150 -200 gpm / ft2 Detention time in flocculator - 20 minutes

Aquarius Design Mixed Media Filter Two-Stage Flocculation w/ MULTIBLOCK® UD Two-Stage Flocculation Tube Settlers

Aquarius Process Operation Backwash Set flow with influent valve Filter level float valve Chemicals added upstream of tank Two floc stages Flow up through tubes and down through filter Water pumped out to storage Filter headloss starts backwash (vacuum) Waste valve opened Tubes drained Backwash pumped through filters into tubes Waste valve closed Tubes filled with clean backwash and placed back in operation

Aquarius Application For water temperature above 50° F, Up to 400 NTU Up to 200 true color Up to 20 mg / L iron Up to 10 mg / L manganese For water temperature below 50° F, reduce above criteria by up to 50 % Higher solids loading than WaterBoy

Aquarius Sweet Spots Economical packaged treatment Use in industrial applications for power, electronics, pulp & paper, potable water, process cooling water and zero discharge Over 300 installations across North America; over 600 worldwide

Summary Economical Plant Designs Flocculation, Tube Settler, & Mixed Media Filter WaterBoy ideal for low flows & smaller footprint Aquarius targeted for larger flow plants & higher solids

Pre-Engineered Water Surface Water Treatment Plants MICROFLOC® Products WaterBoy™ & Aquarius®