A custom presentation for:

Slides:



Advertisements
Similar presentations
Presented by: Your Name HERE
Advertisements

Lighting concepts – Ballasts and Lighting Controls
LAPENNA CONTRACTING PRESENTS.
Start of Presentation ALLUME, LLC High Performance – Energy Efficient Lighting and Controls.
Lighting the Way Efficiently
Metrolight – Committed to Saving Energy Cox Auto Auction 15 MAY 2008.
Save Energy and Money PNM Energy Efficiency Programs
Energy Efficiency 4/29/2015 Lighting Akrem Awad 1.
I can see the light! Energy Efficient Lighting. Energy webinar series.
Lighting. Artificial Light Units of Measurement Input Power – Watts Light Output – Lumens Efficacy* (of light source) – Lumens per watt Efficiency (of.
Presented by: Your Name HERE
Project Review and Lessons Learned LED Lighting Retrofit at Grafton Bethel Elementary School.
Be Off The Grid com Inc. LED TUBE LIGHTING. Replaces existing fluorescent lighting SAVING 70% IN ENERGY COST 8W LED (2 foot) – Size: 26mm(diameter)x602mm(length)
Energy retrofit solution for 400w MH Highbays!! Question:How many fixture lumens do you need to replace one 400w MH highbay? Answer:About 20,000 lumens.
Mary Matteson Bryan, P.E Bi-Level Office Lighting with Occupancy Sensors E3T Field Assessment Mary Matteson Bryan, P.E. January 14, 2011.
Ballast Basics II Welcome to Universal Lighting Technologies e-learning module Ballast Basics II.
| 1 Universal Lighting Technologies ULT Marketing Dimming Distributor Salesperson Training Presented by: Your Name HERE.
LED Lighting. 2 Overview LED Technology Background LED Testing Energy Star DOE Design Lights Consortium ComEd SmartIdeas program.
Lighting Retrofit Training.  Know and understand your local power company incentive program. KEMA is a federal organization that administers several.
| 1 Universal Lighting Technologies ULT Marketing T5 and T5HO Ballasts Distributor Salesperson Training Presented by: Your Name HERE.
Traditional Fluorescent Lamp with Electromagnetic Ballast vs “adapT5” T5 Electronic Ballast adapter Fluorescent Lamp with Electromagnetic Ballast T5 Fluorescent.
| 1 © Universal Lighting Technologies Inc. ULT Marketing Part Number Nomenclature Distributor Salesperson Training Presented by: Your Name HERE.
Distributor Salesperson Training Presented by: Your Name HERE
Energy Efficient Lighting Presented to you by: Bob Fulton with REXEL-USA and Albert Wittyngham with SESCO Lighting Brought to you by Rexel USA and SESCO.
Induction Lighting: “Bringing the Future to Light” October 24,2008.
December 2, 2008 Campus Lighting Retrofits University of Illinois at Urbana-Champaign in conjunction with ICECF Eva Sweeney, P.E., LC, LEED© AP ISTC Sustainability.
| 1 Universal Lighting Technologies ULT Marketing ULTim8® High Efficiency Presented by: Your Name HERE.
| 1 Universal Lighting Technologies ULT Marketing Ballast Basics I Presented by: Your Name HERE.
[DATE] [PLACEHOLDER FOR DISTRIBUTOR LOGO]. Low Wattage T8s: A Win for Customers Cost Savings Product Quality Easy Installation Energy Savings.
Why should we save energy? Americans now spend over $700 billion on energy Americans now spend over $700 billion on energy Energy demand is expected to.
| 1 EVERLINE® LED Sign Tubes Training. Universal is a Member of the Panasonic Group LED Replacement Products Universal continues to expand our LED options.
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
LIGHTING SYSTEMS. Introduction  Electricity used to operate lighting systems represents a significant percentage of electricity consumed in most countries.
November 2, 2011 Comprehensive Lighting: Solutions for the Greater Good David Landers Manager, Business Energy Management Efficiency Connections Northwest.
Do you know what makes LED an energy efficient lighting option? Compared to traditional bulbs, LED light uses 90% less energy and has over 50,000 hour.
| 1 EVERLINE® LED Linear Tubes & Driver Replacement Products Distributor Salesperson Training A custom presentation for: Customer Name Here by Your Name.
| 1 Distributor Training Presentation EVERLINE LED Sign Tubes.
| 1 Universal Lighting Technologies ULT Marketing Lamp Training.
Lighting Retrofit Assembly (LRA)
Converting from T12 to T8 or T5:
Distributor Salesperson Training
A custom presentation for:
ESR Electronic Sign Ballasts
Part Number Nomenclature
Greg Bennorth Director of Product Management, Lamps
2017 Commercial Energy Efficiency Program
Society of American Engineers
LED Driver Training.
•••••••••••••••••••••••••••••••••••••••••••••
CAPE & OUR PPN HISTORY IN BUSINESS SINCE 1953, PPN MEMBER SINCE 2014
LEDlescentTM T8 Ballast-Free Lamps
Regional Sales Manager
Regional Sales Manager
A Patented Product.
Regional Sales Manager
Twenty Questions ? ? This set of questions and answers has been prepared by GE to present the current understanding (May 2006) of provisions contained.
Regional Sales Manager
A Patented Product.
[PLACEHOLDER FOR DISTRIBUTOR LOGO]
Regional Sales Manager
Regional Sales Manager
A custom presentation for:
Regional Sales Manager
LED Driver Training.
Part Number Nomenclature
Regional Sales Manager
Regional Sales Manager
Regional Sales Manager
A custom presentation for:
Introduction Purpose To describe the features and capabilities of two new coin cell supercapacitor series from CDE. Objectives Explain advantages of supercapacitors.
Presentation transcript:

A custom presentation for: ULTim8 Training A custom presentation for: Customer Name Here by Your Name Here

Starting Methods Rapid Start Instant Start Programmed Start There are a number of different methods for starting fluorescent lamps. T8 & T5 lamps, may be started by more than one method. The following is a list of the starting methods and which ballast technologies employ these methods. Rapid Start Magnetic & Electronic Instant Start Programmed Start Electronic Only Instant Start and Programmed Start are the methods currently used for most lighting applications.

Rapid Start Rapid Start ballasts provide filament voltage (heating) and lamp voltage simultaneously. When the lamp filaments reach a temperature that is sufficient for ignition with the lamp voltage applied, the lamps ignite. Glowing of the lamps is visible prior to ignition. Depending upon the lamp voltage, this may not guarantee that the filament is sufficiently heated, resulting in poor lamp life. Cathode voltage remains after the lamp has started consuming approximately 2 Watts per lamp. It was believed that electronic rapid start ballasts would provide longer lamp life than instant start ballasts but this has been proved to be incorrect.

Instant Start Instant Start ballasts operate without heating the filaments. A high voltage is used to ignite the lamps. Instant start operation is more efficient since there is no additional power consumed for heating filaments. Single pin instant start (slimline) lamps must be instant started. Some Bi-pin lamps such as the F32T8 and F54T5HO can also be instant started. Programmed Start is growing in popularity but Instant Start is still by far the largest segment.

Programmed Start Technology for long lamp life! Programmed Start ballasts A.K.A Programmed Rapid Start Utilize electronic technology to provide optimal starting for lamps to achieve the longest lamp life possible. Tests have shown lamp life to be extended three times as long as traditional rapid start ballasts in applications where the lamps are frequently cycled on and off. Programmed Start ballasts can be used in place of rapid start ballasts since they usually wire the same way in the fixture, hence the addition of “Rapid” in the name. Technology for long lamp life!

Best Starting Method Which Electronic Ballast Starting is Best? For the lamp types with a choice of starting methods: Identify the application and expected operating/switching cycle Expected operating hours between starts Is the ballast connected to an occupancy sensor? Use Programmed Start to maintain lamp life when: Ballasts are connected to occupancy sensors which will switch frequently If the lighting is going to be switched on and off frequently Typically less than three hours per start Use Instant start to maximize energy savings when: Ballasts are going to typically remain on for at least three hours between starts

“True” Parallel Lamp Operation / Ballast Factors What do you mean by “true” parallel lamp operation vs. use of series parallel? One of the benefits of ULTim8 ballasts are its “True” Parallel Lamp operation. This means that there is independent lamp operation, which simplifies troubleshooting. Lamps stay lit if one lamp fails. This prevents fixtures from going dark and replacing lamps unnecessarily. Series: In 2L, 3L or 4L applications – if one lamp goes out, all lamps go out. Parallel: In 2L, 3L or 4L applications – if one lamp goes out, all others stay lit. Series-Parallel: In 4L applications – if one lamp goes out, 2 of 4 lamps go out. Why is .71 Ballast Factor better than .77 Ballast Factor? Programmed Start ballasts are available with a .71 ballast factor while instant start ballasts have a .77 ballast factor. A lower ballast factor maximizes energy efficiency. Programmed Start ballasts allow lower ballast factor because you can provide the filament heat necessary to maintain lamp life.

Why Upgrade from T12’s to T8’s? T12 vs. T8 Ballasts Why Upgrade from T12’s to T8’s? T12 Ballasts: Older technology. Majority of T12 lamp production was phased out in July 2012. Primarily were magnetic ballasts. Magnetic T12 ballast production was phased out in July of 2010. Heavy and large. T8 Ballasts: Higher efficiency than T12 ballasts. Electronic design makes them lighter and more compact. Quieter operation. Instant on with no warm-up time. Can lower energy costs. T12 Lamps will Become Less Available and More Expensive T12 Ballasts are Inefficient Retrofitting to T8’s can save up to 40% off your current energy costs. Most often, the energy savings can pay for the cost of the upgrade. T12 Magnetic Ballasts Generate Significant Amounts of Heat Magnetic ballasts lose energy in the form of heat, which adds to air conditioning costs. Upgrades Improve Lighting Quality Improves light output and color quality. Eliminates flickering and buzz that T12’s can cause. Makes your building look better/feel newer. Leads to increased productivity. Before: T12’s installed After: Upgraded to T8’s

ULTim8® Family: Universal’s Offering Universal offers high efficiency T8 ballasts for Instant Start and Programmed Start applications. These ballasts deliver up to 6% additional energy savings over standard electronic ballasts. ULTim8® Instant Start Instant Start technology for continuous operation: maximizes energy savings. ULTim8® Programmed Start Programmed Start and “True” Parallel lamp technology offer fast start time, and lamps stay lit if one lamp fails. ULTim8® High Lumen and High Bay The high efficiency high ballast factor choice for high lumen T8 applications. Linear Fluorescent Lampholders Combine with ULTim8 ballast orders for a more complete solution. Universal’s ULTim8® High Efficiency Family

ULTim8® Family: Primary Benefits ULTim8® Instant Start Benefits: Some of the most efficient ballasts in the industry for maximum energy savings. Available in high efficiency HE normal (.88), EL low (.77), and HEH high (1.18) ballast factor versions. Instant Start technology for continuous operation: maximizes energy savings for long cycle operations. “True” Parallel Lamp operation: Independent lamp operation simplifies troubleshooting. Lamps stay lit if one lamp fails, preventing fixtures from going dark and replacing lamps unnecessarily. THD < 10%. Lamp will auto-restrike as a standard feature allowing replacement of lamps without recycling power. Anti-striation control for better light quality when using energy saving lamps. Universal input voltage, installer friendly. Because these ballasts are CEE and NEMA Premium compliant they may qualify for utility incentives. Backed by 5 year warranty when operated at 75° C max case temperature.

ULTim8® Family: Primary Benefits ULTim8® Programmed Start Benefits: Same benefits as Instant Start plus ... Available in high efficiency HE normal (.88) and EL low (.71) ballast factor versions. Coming soon is HEH high (1.18) ballast factor. Programmed start models feature a “soft start” technology making them the perfect choice for high-cycling applications including those involving occupancy sensors. Programmed Start ballasts are designed to quickly pre-heat lamp cathodes up to their optimum starting temperature and ignite the lamps quickly (within 700 milliseconds). Filament cut out on HE and HEH models for instant start level efficiency. The quick ignition results in long lamp life without the typical long delay during turn-on. Smaller “B” can size (1.0” x 1.5” x 9.5”) for the two lamp version. RoHS compliant. Same 5 year warranty as instant start plus 3-year warranty for HEH modules when operated at 90° C case temperature.

ULTim8® Family: Calculate Energy Savings Show your customers a calculation on their energy savings, here’s how ... (Number of watts saved x annual hours of operation x energy cost) / (1,000 watts per kilowatt) = Total savings per fixture EXAMPLE: Office (60 watts saved x 4,000 hours x $0.10 per Kwh) / 1,000 = $24 saved per fixture annually $24 per fixture x 500 fixtures = $12,000 annual facility savings ULTim8® ballasts save a typical 6 Watts per ballast versus standard electronic ballasts with F32T8 lamps. When combined with new energy saving lamps, ULTim8® can reduce energy consumption by 60 watts or more when retrofitting a 4-Lamp T12 fixture. Consult your customer’s recent utility bill to find their local Kwh rate.

ULTim8® Family: Applications Target Segments Commercial / Education / Office / Retail (EL and HE) For example: bathrooms, hallways, stairwells, gymnasiums, classrooms, libraries, offices, luminaire applications, recessed volumetric strips, wraps, fluorescent high bay, etc. Note that we have three success stories for this segment on our website. The energy cost savings are particularly appealing to this segment. Many systems are optimizing energy efficiency by improving lighting output and quality while at the same time reducing maintenance of the school’s lighting systems. With parallel lamp operation, students are never left in the dark. Warehouse / Industrial / Manufacturing (HEH) High bay fixtures. Light up the aisles for the forklift operator when lighting is needed. Keep spaces lit when and where needed. ULTim8® High Efficiency is perfect for just about every application, especially new construction. Instant Starts are available in high efficiency HE normal (.88), EL low (.77) and HEH high (1.18) ballast factor versions. Programmed Starts are available in high efficiency HE normal (.88), and EL low (.71) ballast factor versions. Coming soon is HEH high (1.18) ballast factor. EL Ballasts: Used often when retrofitting existing T12 fixtures with T8 lamps to tune down lamp output. Application areas include stairwells, hallways, bathrooms and other areas that are lit partially during the day. They are good for using in low light level areas. Change light levels with ballast factor. HE Ballasts: Used often in new construction, the high efficiency version of our standard HP product. Used for frequently switched applications including occupancy sensors and daylight harvesting. They are a good solution for education, commercial offices and retail. HEH Ballasts: Used to overdrive lamps. Use these for areas with high light output. They are a great solution for high bay fixtures, including applications for warehouses, and manufacturing.

ULTim8® Family: Quick Cross Reference Always consult the current spec sheet for details: http://ultballastspecs.unvlt.com/

Thank you for your time today! Take a Virtual Google Tour of our headquarters showcasing our lighting solutions via: http://tinyurl.com/mpj4gwc