Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.

Slides:



Advertisements
Similar presentations
Proposed Deemed Savings and Cost of Oregon Energy Star Builder Option Package for 2009 February 5, 2008.
Advertisements

Low Rise Multi-Family UES Measure (NWESH) Measure Proposal Presentation to the Regional Technical Forum Sept. 19 th, 2012 Spec Development and Analysis.
Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Residential New Construction (NC): Slab Insulation UES Measure Update Regional Technical Forum March 18, 2014.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Residential LED UES Measure Update Regional Technical Forum August 20, 2013.
High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
MVP House in Montana Energy Savings and Costs March 2 nd, 2009 Regional Technical Forum 1.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.
UES Measure Sunsets Regional Technical Forum December 17, 2013.
Northwest ENERGY STAR Specification for Oregon 2012 Active UES Proposal Presentation to the Regional Technical Forum November 1, 2011 Ben Larson, Ecotope.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Model Conservation Standards and Surcharge Recommendation Economic Analysis for for New Single Family Home Construction April 17, 2009.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Presentation, Discussion, and Decision on Deemed Measures for EnergyStar Homes: Zonal Electric Heat Path (BOP2) for ID and MT Ductless Heat Pump Technical.
Lighting Savings Calculations for Northwest Energy Star ® Homes David Baylon.
Northwest Power and Conservation Council Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction June.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Standard Information Workbook (SIW) Update Proposal Regional Technical Forum May 13, 2014.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
Ben Larson 28 September th Avenue NE, Seattle, WA (206) Fax: (206)
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Ben Larson 2 November th Avenue NE, Seattle, WA (206)
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
Commercial Showerhead UES Measure Update Regional Technical Forum April 16, 2013.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Washington Residential Energy Code 2012: Overview 17 December 2013 Ben Larson, Ecotope 1.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
Predicted Savings for NW Energy Star for Homes and WA BuiltGreen Homes Specification Update Single Family New Construction Regional Technical Forum August.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction May 5, 2009.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
RTF Administrative Measure Decisions November 14, 2012.
Display Case Motion Sensors Small Saver Measure Update July 16th, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
Residential Refrigerator UES Measure Update Regional Technical Forum April 16, 2013.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Compliance Software Tool Approval Technical Assistance Manual
Presentation transcript:

Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014

Res New SF Energy Star Homes Measure Overview Current Category: UES Measure Current Status: Under Review Current Sunset Date: March 2014 Reason for Update/Review: Measure recommendation memo suggested these measures be placed under review. Update to new Pro Cost template, update to SEEM94 and update documentation. Baseline Type: Current Practice 2

ID & MT Energy Star Specs ID and MT programs build on the national spec to include: DHW improvements and retain PTCS heat pump commissioning, duct testing, and NW heat pump HSPF. IECC 2009 Z5 + Z6Adjusted Nat’l EStar HVAC Equipment Furnace AFUE80 AFUE90 AFUE Heat Pump HSPF / SEER7.7 / 139.0/14.5 Envelope CeilingR-38 or R-49R-38 RH WallR-20R-21 Adv FloorR-30 SlabR-10, 2-ft or 4-ft2ft - R-10 WindowU-0.35U-0.30 Infiltration and Ventilation Blower Door Test---4ACH50 Mechanical Ventilation--- ASHRAE Std 62.2 (Pt Source) DHW Gas EF Elec EF Low Flow Fixtures---- DuctsSealed Lights: % CFLs, LPD (W/ft 2 )50%, 1.180%, 0.72

ID & MT Ductless Heat Pump Technical Compliance Option (DHP TCO) and Building Option Package (BOP2) Energy Star Specs State Code IECC 2009 Z5 + Z6 DHP TCO (BOP1 + DHP) ID+MT BOP2 HVAC Equipment DHP Zonal Resistance Furnace AFUE80 AFUEZonal Resistance Zonal Electric Resistance Heat Pump HSPF / SEER7.7 / 139.0/14.5 Envelope CeilingR-38 or R-49R-38 RHR-49 RH WallR-20R-21 AdvR-21 + R-5 foam FloorR-30 R-38 SlabR-10, 2-ft or 4-ft2ft - R-10R-10 Full WindowU-0.35U-0.30U-0.30, SHGC≥0.4 Infiltration and Ventilation Blower Door Test---4ACH502.5ACH50 Mechanical Ventilation--- ASHRAE Std 62.2 (Pt Source) HRV 70% Recovery DHW Gas EF Elec EF Low Flow Fixtures----x x DuctsSealed None permitted Lights: % CFLs, LPD (W/ft 2 )50%, 1.180%, %, 0.6

Measure Workbook Update Summary Developed New Construction Baseline SEEM workbook. Ensures consistency across all SF new construction measures. All simulations updated to SEEM 94 from SEEM 92 Updated calibration data used, Phase I and Phase II adjustments made. Latest ProCost template used for this measure workbook. Updated electric and domestic hot water calculations Matches latest RTF workbook for residential DHW tanks workbook. Costs updated from $69 to $ 92 for electric water heater Ventilation calculations done via SEEM Ventilation savings remain unchanged. Ceiling and floor insulation upgrade cost updated using the Standard Information Workbook.

Measure Workbook Update Summary DHP Calibration factors not yet finalized. Based on input from calibration team, DHP calibration adjustments numbers are an average of Zonal and Gas calibration adjustment factors Updated LPD for baseline and efficient case to account for EISA standards. Each case is defined by the percentage of high efficiency lamps. While developing CFL and LED workbooks, staff found that new lighting standards would decrease whole house LPD by 16%. Staff conducted back of the envelope calculations Staff to update residential lighting savings using RBSA SF dataset.

New CFL Savings Numbers Baseline requires 50 % efficient lighting Energy Star home requires 80% efficient lighting. DHP TCO requires 90 % efficient lighting No incremental cost for CFL as EISA compliant and CFL are comparable in cost. % CFL % EISA Compliant Incandescent Updated LPD (W/Sf) Previous LPD (W/sf) 0%100% % %20% %10%

Items for RTF Discussion Change in Savings Updating to SEEM 94 and calibration adjustments decrease heating savings by at least 20 % in all cases. This decrease in savings is larger for gas, and HP heated homes based on calibration.

Summary of Changes Energy Savings have reduced for all HZ and CZ iterations of this measure. Updated package costs are approximately $ 500 lower to existing package costs. Energy Star homes are cost effective for electric HVAC system in all climate zone. For gas HVAC, Energy Star homes are cost effective in three HZ, CZ combinations only.

RTF Proposed Motion: I _________ move that the RTF approve the Energy Star New Construction Single Family ID & MT UES (E2ergy Star Homes, DHP TCO, BOP2) measures to “Proven” category with “Active” status with a sunset date of December, 2015

Washington Residential New Construction Measures Baseline workbook presented by Ecotope in December. Different paths/ options to meet code in WA. Aprrox. 40 prototypes. Ecotope performed ~ 3500 SEEM Runs Staff propose to pick likely scenarios from list of scenarios simulated by Ecotope. Staff will prepare Energy Star options for each scenario. Staff will consult Northwest Energy Star, Ecotope consulting to develop these scenarios WA residential new construction measures will be presented to the RTF in April. Oregon residential new construction measures will be presented to the RTF in April. No Change in methodology; SEEM update