Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
Residential New Construction (NC): Slab Insulation UES Measure Update Regional Technical Forum March 18, 2014.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
UES Measure Sunsets Regional Technical Forum December 17, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum July.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
SEEM 94 Calibration to Single Family RBSA Data Regional Technical Forum January 23, 2013 Analysis Performed ByAdam Hadley Cursory Reviews By Tom Eckman,
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
Prescriptive Duct Sealing in Manufactured Homes: Proposal for Proven UES Adam Hadley Regional Technical Forum August 18, 2015.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
RTF Staff, Subcommittee and Work Updates October 23, 2012.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
RTF Work Plan Mid-Year Re-Programming July 15, 2014.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
Air Source Heat Pump Specifications Proposed Revisions Regional Technical Forum Subcommittee July 2, 2013.
RTF Delivery Verification Guidance Batch 1 Jennifer Anziano Regional Technical Forum May 12, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Residential Weatherization and Ventilation Subcommittee: Infiltration Impact Research Plan Presentation to the Regional Technical Forum December 13, 2011.
Implementer’s Group May 2015 Meeting Debrief and Upcoming Meeting Prep May 19, 2015.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
DHP for New Construction: How to establish the baseline Adam Hadley and Phillip Kelsven RTF Subcommittee December 4, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum December 8, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
PTCS Subcommittee Recommendations ARHI Certification for Standalone Heat Pump Commissioning and Controls Measures AND Simplified Heat Pump Sizing Method.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Non-Proven Residential Duct Sealing Measures: Research Strategy Josh Rushton and Adam Hadley Research and Evaluation Subcommittee October 7, 2015.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
Heat Pump Water Heaters: Interior, Ducted Installations Presentation to the Regional Technical Forum December 13, 2011 Ben Larson, Ecotope
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014

Background – This is a follow-up to: The August 2014 presentation – At that meeting, the RTF put a bunch of issues on the whiteboard. And The September 2014 presentation – At that meeting, the RTF: adopted the proposed Weatherization savings, but not the HVAC measures gave staff the direction to add measure identifiers to the heat pump conversion measures. Background - 2 Today, we’ll revisit the HVAC Measures

Measure(s) Overview Overview - 3 Measures 1. ASHP Conversions - Convert existing electric FAF to central air source heat pump 2. ASHP Upgrades - Install a new a) 9.0 ASHP, or b) Variable Capacity HP 3. Heat Pump Commissioning, Controls, & Sizing (CC&S) - When installing a new heat pump, follow CC&S spec. 4. Performance-based Duct Sealing - Tighten existing duct system to spec. 5. Ductless Heat Pumps - Install DHP in main living area of zonal electric heated house. Measure Developers RTF, Ecotope, BPA Technical Subcommittee Review Yes Research & Evaluation Core Group Review Yes, for CC&S Research Plan.

UES Key Inputs Notes: All measures are additive (except: “9.0 upgrade + VCHP upgrade”, and DHP’s). Things in red are new, as compared to existing measures. ASHP = Central air-source heat pump Overview - 4 MeasureBaselineEfficient-Case Measure Interaction Methodology Measure Category ExistingProposed ASHP Conversions Existing electric FAF New Standard Practice ASHP Measure Identifiers (Good, Fair, Poor) Proven ASHP Upgrade (9.0) New Standard Practice ASHP New 9.0 or > HSPF ASHP “Option 3”Proven ASHP Upgrade (VCHP) New Standard Practice ASHP New 10.0 or > HSPF inverter- driven ASHP “Option 3”ProvisionalProven Heat Pump Commissioning, Controls, and Sizing New Standard Practice ASHP New Heat Pump installed to CC&S Spec “Option 3”ProvenPlanning Performance-based Duct Sealing RBSA Average Duct Leakage 9% Leakage“Option 3”ProvenProvisional Ductless Heat Pumps Existing zonal electric heat DHP in main living area “Option 3”Proven

“SEEM-affected HVAC Measures Subcommittee” Dec 2, :00pm – 4:00pm Heat Pump Conversion Measure – Reviewed and recommend the RTF use the measure identifier methodology and associated calculator. (David Baylon agreed, too, afterward.) Commissioning, Controls, and Sizing Measure – Reviewed and recommend the RTF adopt the revised measure specifications. – Agreed to use a 90% compliance rate factor in the planning UES estimate. – Agreed (with quick review) the Research Plan looks reasonable and will get us closer to proven category. Performance-based Duct Sealing Measure – Reviewed and agreed with baseline and efficient-case assumptions for the provisional UES estimate. – Agreed the “Research Plan” should be simply to wait for BPA’s evaluation results, and re-assess at that time. Technical Subcommittee - 5 Attendees: Mark Jerome Adam Hadley Rick Knori David Bopp Bill Harris Mark Johnson Courtney Dale Robert Weber Tom Leinhard Mohit Chhabra David Baylon Josh Rushton Cory Read Robert Davis Thomas Anreise Jim Maunder Ben Larson Bob Davis Jenn Anziano

Air-Source Heat Pump Conversions ASHP Conversions - 6

Heat Pump Conversion Measure Identifiers Previous Proposal (Option 3) – HP Conversion savings 3279 kWh/yr Today’s Proposal (measure identifiers) – Calculator tool [LINK] to establish insulation levels[LINK] Method: Evenly split the range of possible savings (based on range of Uo’s in RBSA) into three bins – HP Conversion Savings (Heating zone 1) 7020 kWh/yr where house has “Poor Insulation” 4815 kWh/yr where house has “Fair Insulation” 2610 kWh/yr where house has “Good Insulation” Example : – House with eFAF receives attic insulation, wall insulation, floor insulation, and heat pump. Compare the sum of savings with various orders of installation of the heat pump (before, after, and in-between insulation jobs; assume 1-year between each measure installation). Sum of savings should be the same. ASHP Conversions - 7 Given: Previous Proposal Today’s Proposal Reminder: Subcommittee reviewed and agreed with this methodology. Changes made after the subcommittee review: Incorporate Phase II calibration, and run methodology for heating zones 2 and 3.

Remaining Question from Subcommittee Should Duct Sealing be modeled as “last measure in”, or “first measure in”? – Savings shown here use LMI. Justification: Less likely to double-count savings. (And it’s how we’ve done things in the past.) – Some on subcommittee recommended FMI. Justification: The RBSA is a good reflection of what houses look like. We don’t want to undercount savings. – (Q: Why not use “Option 3”? A: Complexity) ASHP Conversions - 8

Measure Cost Inputs Measure cost methodology same as proposed in August Measure Life: 15 years ASHP Conversions - 9

All measures are cost-effective ASHP Conversions - 10 Results

All Measures are cost-effective, except "Good Insulation" HZ3 (all cooling zones). ASHP Conversions - 11 Results

Decision “I _________ move the RTF approve the updates to the measure definition, cost, life, and savings for the UES measure Single Family Heat Pump Conversions and set the measure to Proven category with Active status and a sunset date of 12/2019.” ASHP Conversions - 12

Air-Source Heat Pump Upgrades ASHP Upgrades - 13

Measure: Upgrade to 9.0 HSPF Changes – Unit Energy Savings Used updated, calibrated SEEM “Option 3” for measure interactions Measure Cost: $81 ASHP Upgrades - 14

Changes Measure: Upgrade to Variable Capacity Heat Pump Unit Energy Savings – Used updated, calibrated SEEM – “Option 3” for measure interactions – Incorporated findings from provisional research (plan)(plan) Report: Hunt, W Laboratory Testing of Residential, Variable Speed Heat Pump. Bonneville Power Administration. Portland, OR. – Lab test in “Efficiency Mode” Report: Larson, B., B. Davis, J. Uslan, and L. Gilman. “Residential Variable Capacity Heat Pump Field Study.” Prepared for BPA by Ecotope. August 30, [LINK][LINK] – 8-week field study of 6 units in Bend – Units were set up in “Comfort Mode”; otherwise good comparison with lab results – Developed SEEM performance curves Measure definition: 10.0 HSPF or higher; central system with variable capacity using an inverter driven compressor Note: Because measure is not cost-effective, this measure received less due-diligence from RTF Contract Analysts than DHP’s and HPWH’s, for example. Inputs and savings look reasonable, however. ASHP Upgrades - 15

Measure: Upgrade to Variable Capacity Heat Pump VCHP Install Cost: $3,958/ton – Limited Data – Source: Invoices, Project Bids, Installer Interviews – Used lower quartile because of “extras” – 2014$’s Measure Cost (3 ton, 2006$’s) – 8.5 HSPF (baseline) $5,523 (Source: Mark Jerome) – VCHP $10,443 – Measure cost: $4,920 ASHP Upgrades - 16

All 9.0 HSPF upgrades are cost-effective. None of the VCHP upgrades are cost-effective. ASHP Upgrades - 17 Results

Decision ASHP Upgrades - 18 “I _________ move the RTF approve the updates to the measure definition, cost, life, and savings for the UES measure Single Family Heat Pump Upgrades and set the measure to Proven category with Active status and a sunset date of 12/2019.”

Heat Pump Commissioning, Controls, and Sizing HP CC&S - 19

Changes Specifications [LINK] updated[LINK] – Subcommittee agreed with where the July 2013 subcommittee landed, and agreed with removing PTCS QC/QA/Certification/Training requirements (reason for removing “PTCS” from the name).July 2013 subcommittee Research Plan [LINK][LINK] – Technical Subcommittee agreed with research plan – Evaluation Subcommittee raised some questions and needs more time – Summary Field visit of 150 Baseline Houses Field visit of 150 Efficient-case Houses Results will be used to true-up model input assumptions to today’s practices Budget: ~$350,000 Unit Energy Savings (Planning) – Used updated, calibrated SEEM – “Option 3” for measure interactions – 90% specification compliance rate (technical subcommittee-proposed) – Modeling assumes 80% airflow in baseline, based on 2005 NEEA/Ecotope Heat Pump Study (now a capability of SEEM) HP CC&S - 20

All measures are cost-effective. Note: Measure Cost = $512 (2006$’s), per SIW (no change) HP CC&S - 21 Results

Decision HP CC&S - 22 “I ________ move the RTF approve the updates to the measure specifications, cost, life, and savings for the UES measure Single Family Heat Pump Commissioning, Controls, and Sizing and set the measure to Planning category with Under Review status and a sunset date of 4/2015.” Note: The purpose of the Under Review status and sunset date of 4/2015, is to give time to finalize the Research Plan.

Performance-based Duct Sealing Performance-based Duct Sealing - 23

Changes Unit Energy Savings (Provisional) – Used updated, calibrated SEEM – “Option 3” for measure interactions – Baseline now set at average RBSA duct leakage levels Research Plan: – Plan: Wait for BPA re-evaluation, then re-assess No separate written plan, just this. – Sunset date 12/2015 (BPA plans to finish Q4-2015) Removed “PTCS” from the name – Seen as a program branding – Avoid confusing CC&S with duct sealing – Avoid confusing with “prescriptive duct sealing” Performance-based Duct Sealing - 24

All measures are cost-effective. Note: Measure cost = $750 (2006$’s), per SIW (no change) Performance-based Duct Sealing - 25

Decision “I ________ move the RTF approve the Provisional Research plan and the updates to the measure definition, cost, life, and savings for the UES measure Single Family Performance-based Duct Sealing and set the measure to Provisional category with Active status and a sunset date of 12/2015.” Performance-based Duct Sealing - 26

Ductless Heat Pumps DHP - 27

Changes Unit Energy Savings – Incorporated “Option 3” for measure interactions DHP - 28

All Proposed measures are cost-effective, except HZ3 CZ1. (No change from Existing.) DHP - 29

Decision “I ________ move the RTF approve the update (“Option 3”) to the measure savings for the UES measure Single Family Ductless Heat Pumps. The measure definition, cost, life, and sunset date will remain the same.” DHP - 30

Additional Slides 31

Decisions “I _________ move the RTF approve the updates to the measure definition, cost, life, and savings for the UES measure Single Family Heat Pump Conversions and set the measure to Proven category with Active status and a sunset date of 12/2019.” “I _________ move the RTF approve the updates to the measure definition, cost, life, and savings for the UES measure Single Family Heat Pump Upgrades and set the measure to Proven category with Active status and a sunset date of 12/2019.” “I ________ move the RTF approve the Planning Research plan and the updates to the measure definition, cost, life, and savings for the UES measure Single Family Heat Pump Commissioning, Controls, and Sizing and set the measure to Planning category with Active status and a sunset date of 12/2015.” “I ________ move the RTF approve the Provisional Research plan and the updates to the measure definition, cost, life, and savings for the UES measure Single Family Performance-based Duct Sealing and set the measure to Provisional category with Active status and a sunset date of 12/2015.” “I ________ move the RTF approve the update (“Option 3”) to the measure savings for the UES measure Single Family Ductless Heat Pumps. The measure definition, cost, life, and sunset date will remain the same.” All - 32

Slide from August 2014 Presentation Methodology for Estimating Costs for FAF  HP and Zonal  DHP Measures Net Incremental Cost = Heat Pump Cost – CAC Cost Credit – RAC Cost Credit – FAF Replacement Cost (FAF replacement cost = $1030 for HP; not applicable to DHP) 33 3