Presentation is loading. Please wait.

Presentation is loading. Please wait.

Copyright© 2003 Avaya Inc. All rights reserved Avaya Online UPS 1000-2000 VA, 120V.

Similar presentations


Presentation on theme: "Copyright© 2003 Avaya Inc. All rights reserved Avaya Online UPS 1000-2000 VA, 120V."— Presentation transcript:

1 Copyright© 2003 Avaya Inc. All rights reserved Avaya Online UPS 1000-2000 VA, 120V

2 2 Copyright© 2003 Avaya Inc. All rights reserved Avaya Applications Advanced power protection for: –DEFINITY  One System –DEFINITY  ProLogix  Solutions –DEFINITY  BCS –GuestWorks  System –MERLIN MAGIX  Solutions

3 3 Copyright© 2003 Avaya Inc. All rights reserved Key Features Robust Online topology Advanced Battery Management (ABM) Extended Battery Modules (EBMs) Load Segments Two-in-One form factor 2U rack-mount height Hot-swappable batteries X-Slot™ Communications Power management software bundle

4 4 Copyright© 2003 Avaya Inc. All rights reserved PowerInput/OutputInput/OutputDimensions SAPRatingVoltage 1 Connection(s) ( H x W x D) 2 Weight 1000 VA/ 5-15P/ 408357010 700 Watts 120 Vac (6) 5-15R 3.5 x 17.0 x 19.4 in. 34 lb 700290273 1000 VA/ 5-15P/ w/Web/SNMP Card 700 Watts 120 Vac (6) 5-15R 3.5 x 17.0 x 19.4 in. 34 lb 1500 VA/ 5-15P/ 408357028 1050 Watts 120 Vac (6) 5-15R 3.5 x 17.0 x 19.4 in. 50 lb 194384 1500 VA/ 5-15P/ w/Web/SNMP Card 1050 Watts 120 Vac (6) 5-15R 3.5 x 17.0 x 19.4 in. 50 lb 2000 VA/ 5-20P/ 700019300 1400 Watts120 Vac (4) 5-15R & (2) 5-20R 3.5 x 17.0 x 19.4 in. 50 lb Extended Battery Modules (EBMs) 408357044 (24V EBM)Standard (use with 1000VA)--Connector 3.5 x 17.0 x 19.4 in.65 lb 408357051 (48V EBM)Standard (use with 1500/2000VA)--Connector 3.5 x 17.0 x 19.4 in.65 lb 1. User-selectable for 100, 110, 120, & 127 Vac via front panel. Automatic 50/60 Hz frequency selection. 2. 19-inch wide front panel with a 17.0-inch wide chassis in rack configurations. In tower configurations, the unit is 17.0 inches tall. Model Selection Guide

5 5 Copyright© 2003 Avaya Inc. All rights reserved Online Design All the performance you expect from a double-conversion online design... –Continuous sine wave recreation –Tight output regulation (±3% or better) –Isolation of load from utility –Frequency correction –Minimal time on battery –Harmonics isolation... Along with high efficiency –Reduced energy consumption, saving end-users $100s in annual energy costs –Increased component life from heat reduction and sensible switching voltages

6 6 Copyright© 2003 Avaya Inc. All rights reserved Online Design High efficiency –Higher efficiency yields lower operating costs and longer electronic component life Reliability –Evaluates operating environment and tests portions of its engine in the presence of stable utility power –Uses latest advances in semiconductor technology –Increased reliability results in longer UPS life and fewer service calls Multi-stage fan control –Adapts to operating environment to provide correct airflow –Increases fan service life –Reduces audible noise

7 7 Copyright© 2003 Avaya Inc. All rights reserved Online Design Wide input voltage range –Reduces battery usage –Preserves batteries for power failures--when you need maximum runtime –Extends UPS service life –Reduces battery replacement costs EnergyShare –In severe brownout conditions, the UPS takes power from both the utility and battery –Reduces battery usage –Extends runtime and service life of the battery

8 8 Copyright© 2003 Avaya Inc. All rights reserved Online Topology Diagram UtilityLoad Internal Automatic Bypass Battery AC to DC Rectifier DC to AC Inverter Bi-Directional Power Converter Filtering

9 9 Copyright© 2003 Avaya Inc. All rights reserved Doubles battery service life by charging only when needed Optimizes recharge time Does not trickle charge and starve the electrolyte Intelligent microprocessor controlled - Only true & automatic battery check (periodic, controlled discharge) for most accurate advanced failure protection Sleep Feature - no unnecessary battery “drain” Advanced Battery Management (ABM)

10 10 Copyright© 2003 Avaya Inc. All rights reserved ABM: 3-Stage Charger 1. Rapid recharge to approximately 90% –Restores batteries quickly –UPS is ready for next power outage –Adaptive charger control: adjusts battery charging algorithm to quality of AC input 2. Float charge to 100% –Completely charges batteries, but prevents overcharging 3. Rest mode –With charger turned off, UPS conducts accurate tests to monitor battery health and provide accurate runtime predictions

11 11 Copyright© 2003 Avaya Inc. All rights reserved ABM Diagnostics Monitoring algorithms –Verifies discharge curve during commissioning test –Continuously compares versus this profile Battery impedance test –Verifies battery condition and monitors changes in the internal resistance of the battery Accurate battery runtime predictions –Actual runtimes are compared to ideal runtime curve programmed into UPS Advanced warning –When disparity between runtime curves reaches a predetermined point, UPS provides up to 60 days warning of the end of useful battery service life

12 12 Copyright© 2003 Avaya Inc. All rights reserved Informative User Interface On Button (Start-On-Battery) Overtemperature Overload Load Level/ Battery Level Bypass Mode Alarm Silence/Test Button Off Button Battery Mode Normal Mode (UPS On) Site Wiring Fault Self-Test Replace Battery (ABM) Note: rotate 90° for cabinet configuration

13 13 Copyright© 2003 Avaya Inc. All rights reserved Extended Battery Modules (EBMs) 2U One EBMTwo EBMs Add EBMs to extend backup time In rack-mount configurations, each EBM occupies only 2U (3.5 inches) of rack space

14 14 Copyright© 2003 Avaya Inc. All rights reserved EBM Connection Attach EBMs with simple daisy-chain connection EBM #1 EBM #2

15 15 Copyright© 2003 Avaya Inc. All rights reserved Battery Runtimes (1000 VA model) Standard InternalOne Two Load BatteriesEBMEBMs 200VA/140W37271546 400VA/280W19142278 700VA/490W 972156 850VA/595W659124 1000VA/700W548104 Note: Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

16 16 Copyright© 2003 Avaya Inc. All rights reserved Battery Runtimes (1500 / 2000 VA models) Standard InternalOneTwoThreeFour Load BatteriesEBMEBMsEBMsEBMs 400VA/280W46177331501682 700VA/490W2596180272370 850VA/595W2176142214292 1000VA/700W1661115174237 1250VA/875W114687131179 1500VA/1050W83770106144 1800VA/1260W*6305785116 2000VA/1400W*5264974100 *Runtimes do not apply for the 1500 VA model. Note: Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

17 17 Copyright© 2003 Avaya Inc. All rights reserved Hot-Swappable Batteries No need to shut down your critical load when replacing batteries

18 18 Copyright© 2003 Avaya Inc. All rights reserved Two-in-One Form Factor TowerRack-Mount Versatile form factor provides the option of installing the UPS in an equipment rack or as a tower

19 19 Copyright© 2003 Avaya Inc. All rights reserved Maximum Power Density: 2U Rack Height 2U Minimizing the size of the UPS saves rack space for other equipment

20 20 Copyright© 2003 Avaya Inc. All rights reserved Load Segments Individual control of two Load Segments

21 21 Copyright© 2003 Avaya Inc. All rights reserved Load Segments Power down sequencing of Load Segments –Extends runtime for critical devices Power up sequencing of Load Segments –Orderly power up of connected devices Scheduled on/off times –Turn off equipment for security and power conservation

22 22 Copyright© 2003 Avaya Inc. All rights reserved Load Segments: Independent Control Load Segment 1: Server Load Segment 2: Monitor (60% of total server load on average) Control both Load Segments independently using LanSafe III/FailSafe III software

23 23 Copyright© 2003 Avaya Inc. All rights reserved Load Segments: Shutdown During an extended power failure, you can extend runtime for critical devices by shutting down non-vital equipment, such as monitors 60% of load

24 24 Copyright© 2003 Avaya Inc. All rights reserved Load Segment: Rebooting Reboot separate Load Segments without shutting down the entire UPS Locked up server Load Segment 2: Server 2 Load Segment 1: Server 1

25 25 Copyright© 2003 Avaya Inc. All rights reserved Power Scheduling Configuration Configure on/off times for each Load Segment or the entire UPS Attach computer that controls UPS to the correct Load Segment Configure power up sequencing Set power down sequence in the event of a power failure

26 26 Copyright© 2003 Avaya Inc. All rights reserved X-Slot™ Web/SNMP Card X-Slot Rear Panel Standard unit is equipped with an RS-232 serial communications port and an alarm adapter that works perfectly with Definity ® ; an optional, hot-swappable Web/SNMP card may be ordered, too. Select 1000 and 1500 VA models have the Web/SNMP care pre-installed.

27 27 Copyright© 2003 Avaya Inc. All rights reserved Isolated Alarm Card Designed and tested for use with Avaya product –25-pin cable not supplied Isolated contact closures Serial communications –9-pin to 9-pin cable included

28 28 Copyright© 2003 Avaya Inc. All rights reserved Alarm Card Pin-Outs Pin #Function Output 14Utility fail 15Utility fail return 18UPS On Bypass Return 19UPS On Bypass 24Battery Low 25Battery Low Return 7Ground 824 Volts 25 Pin Connector Pin #FunctionInput / Output 1No Connection 2TxDOutput from Lucent Module 3RxDInput To Lucent Module 4DTR, PnP InputInput To Lucent Module 5Ground 6DSROutput from Lucent Module (tied to pin 4) 7RTSRTS Input to Lucent Module (secondary PnP) 8No Connection 9+8-24 DC Power (output from Module) 9-Pin Connector

29 29 Copyright© 2003 Avaya Inc. All rights reserved LanSafe Compatible with all major operating systems. Visit www.powerware.com/avaya for details Free Software Bundle

30 30 Copyright© 2003 Avaya Inc. All rights reserved Power Management Software Capabilities Prioritized, sequential shutdown of all network devices –Power loss and low battery warnings –Work-in-progress is saved throughout network Network-wide monitoring, control, and testing Support multiple network devices with a single UPS Compatible with other manufacturers’ UPSs Customizable Alerts –Paging and e-mail capabilities

31 31 Copyright© 2003 Avaya Inc. All rights reserved REPO/Network Transient Protector Shut down UPS from a remote location with REPO port; ideal for rack applications Network Transient Protector provides protection from “back door” disturbances that travel through phone/network lines

32 32 Copyright© 2003 Avaya Inc. All rights reserved Rear Panel: 1000/1500 VA Communications Port/Alarm Adapter Battery Connector REPO Port/ Network Transient Protector 6-foot Line Cord with 5-15P Load Segment 2 (3) 5-15R Load Segment 1 (3) 5-15R Bottom end in tower configuration

33 33 Copyright© 2003 Avaya Inc. All rights reserved Rear Panel: 120V, 2000 VA Circuit Breaker Battery Connector REPO Port/ Network Transient Protector 6-foot Line Cord with 5-20P Load Segment 2 (4) 5-15R Load Segment 1 (2) 5-20R Communications Port/Alarm Adapter


Download ppt "Copyright© 2003 Avaya Inc. All rights reserved Avaya Online UPS 1000-2000 VA, 120V."

Similar presentations


Ads by Google