New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) www.autoflame.com Autoflame Training 2014.

Slides:



Advertisements
Similar presentations
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Advertisements

Total HVAC Control from anywhere Easy control that can save a fortune
BurnerMate Universal A Complete Boiler Control System.
KX-NS1000 Initial Set Up For step by step : 16 May,
Remote Monitoring and Management Solutions ®
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Finding That Elusive Pot of Gold or Networking Your Shelter Rebecca Peltzer & Jennifer Bradley, Polk County – Air Quality Steve Drevik, Agilaire.
Hands-On Microsoft Windows Server 2003 Administration Chapter 11 Administering Remote Access Services.
Training.
CCNA 2 v3.1 Module 2.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Copyright © Anviz Global Inc. USA Anviz Online Training Lesson 11 : Anviz product remote access Anviz International Technical Support Team.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
CCNA 1 Module1. Objectives Internet Connections Physical – NIC card to connect to local net Logical – Use a standard set of protocols (TCP/IP) Applications.
ADAM-5000/TCP- Distributed Ethernet I/O
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
SCADA and Telemetry Presented By:.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
The Vision of a Leader Rapid Eye Plus Technical Training.
11 NETWORK PROTOCOLS AND SERVICES Chapter 10. Chapter 10: Network Protocols and Services2 NETWORK PROTOCOLS AND SERVICES  Identify how computers on TCP/IP.
IRRInet & ICC System Concept
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
1 Chapter Overview Using the New Connection Wizard to configure network and Internet connections Using the New Connection Wizard to configure outbound.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
T-Link II Secure Internet Alarm Communication. Product Goals… High level encryption Software upgrades via network Universal compatibility Non-Static IP.
Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access
M340 Modbus Plus Proxy Link legacy systems to Ethernet
NetVu Console Product Training V2.0 US.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions PID Control (P)roportional (I)ntegral Internal Stat PID (D)erivative Further.
World Leaders in Combustion Management Solutions Training School Autoflame Training 2013 PID.
World Leaders in Combustion Management Solutions Taiwan introduction.
World Leaders in Combustion Management Solutions ModuleScreenshots Normal Operation Features Commissioning The Mk7 MM System.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (D.T.I.) THE MK7 DATA TRANSFER.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
World Leaders in Combustion Management Solutions ModuleScreenshots Gas Setup Sampling The Mk7 E.G.A Cell Status Further Information.
Intelligent Boiler Sequencing
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
CUE – Make Any Pump an E-Pump
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
Hardware Introduction – Standard vs Q.i
Service Section Technical Training December 2005.
World Leaders in Combustion Management Solutions Mini Mk7 Evolution Autoflame Training Mini Mk.7 Evolution.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
New product introduction:
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
World Leaders in Combustion Management Solutions OverviewExplanationFurther Information Application Further Information Explanation Introduction Application.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Xbox Wireless Errors & Troubleshooting. Network: Failed Internet: Failed Xbox LIVE: Failed NAT: Connection Warning.
Overview Of Autoflame. Schedule Overview of Autoflame products – MM Controls: Mk8 & Mini Mk8 – Exhaust Gas Analyser (EGA) – Data Transfer Interface (DTI)
Frequently Asked Questions (FAQ)
C1300 advanced circular chart recorder
How SCADA Systems Work?.
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Total HVAC Control from anywhere Easy control that can save a fortune
Field installable, upgradeable and scaleable
Presentation transcript:

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014 Mk7 Data Transfer Interface

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Contents 1.Introduction 2.Features & Benefits 3.Available Information 4.Remote Control 5.CEMS Auditing 6.Mk.7 I/O Module 7.Mk.7 DTI Connections 8.Options & Parameters 9.DTI Configuration 10.Troubleshooting

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 Data Transfer Interface (DTI) Gateway for communicating with the Autoflame range of products Collects and stores information from up to: Information is available through Ethernet and RS422 connections Can be viewed over a Local Area Network, and over the internet Modbus, and Autoflame CEMS Auditing Software  10 x MM units  10 x EGAs  10 x I/O modules

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 DTI Features 2 years of data Animated Mk.7 MM, Mini Mk.7 MM & Mk.7 EGA screens Incorporates external boilerhouse equipment via the Mk.7 I/O modules  Firing rates  Actual or Required Pressures/Temperatures  Servo / VFD positions  Exhaust Gas data  Water Level data  Lockouts/Errors/First Outs  Gas/Air/Oil pressures  Sequencing data  TDS Values

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Available Information – MM Through the DTI touch-screen, the CEMS Audit Software, and via Modbus: MM type – Mini Mk.7, Mk.7 Required/Actual values Firing rates (%) Fuel selected, flow metering values Servos, VFD full values Number of VSD’s, output and feedback history Burner status Sequencing status, shuffle sequencing and lead boiler status Enabled/Disabled status Lockouts, error and first out status

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Screenshot – M.M. Screens

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Available Information – EGA Through the DTI touch-screen, the CEMS Audit Software, and via Modbus: O 2, CO 2, CO, NO, SO 2 and NO 2 values Exhaust gas temperature Ambient temperature Combustion efficiency E.G.A. warning and error conditions

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Available Information – Water Level Through the DTI touch-screen, the CEMS Audit Software, and via Modbus: Operational information such as steam output Makeup flow, condensate return and steam temperature Pump status, feedwater VSD output and valve position Alarm status and First Out annunciation status Probe status, probe signal, commissioned signal values Steam flow metering data End of probe, 2 nd low, 1 st low, control point and high water information

World Leaders in Combustion Management Solutions Mk7 Data Transfer Interface (D.T.I) Modulating Feed Water Control

World Leaders in Combustion Management Solutions Mk7 Data Transfer Interface (D.T.I) Pump On/Off Feed Water Control

World Leaders in Combustion Management Solutions Mk7 Data Transfer Interface (D.T.I) Historical Record of Water Level Alarms

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Input values accepted by the DTI Setpoint Control Lead Boiler Selection Enabling/Disabling of boilers Shuffle Sequencing Input Output Labelling & control Remote Load Index control

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Setpoint Control

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Lead Boiler Select

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Remote Monitoring & Control Modbus connection over RS422 connection Modbus TCP/IP connection over Ethernet connection C.E.M.S. Auditing software can be used over the Ethernet connection: NOTE: Modbus & C.E.M.S Audit Software can be used simultaneously, both on Ethernet, and RS422.  LAN  Internet - business/home network  Internet - GSM modem – separate from business network (useful when sites do not allow 3 rd party connections to computer network)  Single PC use

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 D.T.I. on a Modbus Network

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) D.T.I. - Ethernet Network & C.E.M.S Auditing Software

System Schematic

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) CEMS Audit Software Replicates the touch-screen as seen on the DTI LAN, or internet connection Upload site images (bitmap format) including: Download MM commissioned data Synchronisation and download of recorded DTI data Remote monitoring of MM and EGA data Remote control of the Autoflame system  Electrical drawings  Mechanical drawings  Technical specifications  Boiler images

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) CEMS Audit Software Supervisor version Supplied with the Mk.7 DTI Allows a connection to a single DTI Manager version Additional software Connects to multiple DTI sites Perfect for service engineers, clients in charge of multiple sites etc.

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Screenshot – M.M. Screens

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI)

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 DTI – CEMS Continuous Emissions Monitoring System Auditing function – requires CEMS, EPA or MCERTs EGA Only requires one additional direct connection between EGA and DTI  Totalised gaseous volumes of O 2, CO 2, CO, NO, SO 2 and NO 2  Totalised gaseous weights of O 2, CO 2, CO, NO, SO 2 and NO 2  Fuel flow totals (either from MM or 4-20mA input from flow meter)  Fuel cost totals  Cell degradation  Cell replacement graphs

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 Input Output Module

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 Input Output Module The Mk.7 Input Output (I/O) Module now has the following connections: 6 x Analogue Inputs0–10V, 0–20mA or 4–20mA 6 x Analogue Outputs 0–10V, 0–20mA or 4–20mA 16 Digital Inputs 110V or 230V 8 Volt Free Contacts Mk.7 I/O configuration software Quick and simple to set ranges Can be used standalone to totalise the analogue input values

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Screenshots - Configuration

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 I/O Module – Alarms & Features When used in conjunction with the Mk.7 DTI Totalising of analogue values Monitoring of digital values Control of digital and analogue output signals Averaging of multiple analogue inputs to be output as a single signal Configurable alarms for digital inputs Configurable alarms for analogue inputs On breach of analogue signal, possibility to change volt free contact

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 I/O Module – O2 Interface Operation (O2 Module) A new development with the Mk.7 I/O Module, is the ability to utilize the I/O as an O 2 interface. This enables a 3 rd party O 2 probe to be added to the Autoflame system for trim operation and efficiency calculations. This is done by using a plug in O 2 Module to enable data communications. A 0-20mA/4-20mA signal is required by the O 2 module to provide the O 2 reading to the Autoflame system. A 0-10V signal is required by the O 2 module to provide a stack temperature reading to the Autoflame system. Replacement for the O 2 Interface module

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) DTI Wiring Schematic

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 DTI – Relevant MM Options & Parameters OptionDescription Option 3Mk.6/Mk.7 D.T.I. communication speed Option 16Sequencing/Remote control enable Option 30Lowest Pressure/Temperature accepted by M.M. from D.T.I. Option 31Highest Pressure/Temperature accepted by M.M. from D.T.I. Option 33Unit I.D. Number (each has to be unique) Option 34Burner Rating (Option 77 sets units) Option 57Fuel Flow Metering (must be entered) Parameter 57Highest M.M. unit I.D. number Parameter 101Shuffle sequencing enable/disable

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 DTI Configuration - Network Standard networking protocols DHCP Compatible Static IP address Subnet mask Default Gateway DNS Name DNS Server Port number

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Mk.7 DTI Configuration – DTI Configurable through the DTI touch-screen: Modbus Read/Write ability DTI site name Pressure/Temperature setup Password protection Ancillary I/O modules CEMS configuration options Metric/Imperial unit selection Global setpoint ranging Add, Edit, Delete boilers, EGAs and I/O modules Restart DTI without cycling panel power

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Troubleshooting IssueResolution No communications to DTICheck wiring from units, check screening, turn on IBS diagnostics and check comms LEDs, check ID Nos, check Fuel Flow Metering No Network connection to DTICheck network configuration, attempt to ping DTI from computer on network, check Network cable Incorrect password error when connecting to DTI with CEMS Auditing Software Check password, check you are connecting to the correct DTI, check for the correct DTI access code in the site configuration screens Can’t change setpoints, enable or disable MM units Check option 16 on each of the MMs is set to 2 or 3

New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Thank you for listening