Presentation is loading. Please wait.

Presentation is loading. Please wait.

New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S., MCERTs.

Similar presentations


Presentation on theme: "New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S., MCERTs."— Presentation transcript:

1 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S., MCERTs & EPA E.G.A.’s

2 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Contents Introduction Standard E.G.A. Updates C.E.M.S. E.G.A. Auditing Functions EPA E.G.A. Self-Calibration Heated Sample Line MCERTs E.G.A. Temperature Calibration

3 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Introduction The Autoflame Exhaust Gas Analyser is an inexpensive, reliable way of monitoring combustion gases. Further development has enabled us to log this data to an internal storage device for combustion analysis, as well as meet certain approvals in both the US and the EU. These new developments can be found in the new range of Mk.7 E.G.A. products. Standard E.G.A. C.E.M.S. E.G.A. EPA E.G.A. MCERTs E.G.A.

4 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Standard Mk.7 E.G.A. The Standard Mk.7 E.G.A. provides the following features: 10.4” Touch-Screen Trim on the O2, CO2 & CO when using an M.M. 24 hours of exhaust gas, temperature & efficiency datalogging Combustion limits (i.e. absolute and offset limits from commissioned data) Operates as either a standalone unit, or with an M.M. providing trim 6 x 4-20mA outputs providing gaseous values, efficiencies & temperatures Cell Status and logged unit errors/faults Exhaust gas calibration

5 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. E.G.A. The Continuous Emissions Monitoring System (C.E.M.S.) E.G.A. has the following features: 2 years of data logging for the following information: O2, CO2, CO, NO, NO2, SO2 weights, volumes and readings at current firing rate, and totalised (scalable) Temperatures, pressures, efficiencies Fuel consumed (based on MM fuel flow metering, or a fuel flow meter) at current firing rate and totalised value (scalable) Provides ability to totalise emissions histories across multiple E.G.A.’s through the Mk.7 D.T.I. This Period Last Year (TPLY) comparison of data for weights, volumes and average readings.

6 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

7 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

8 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

9 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

10 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

11 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing Function Screenshots

12 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Upgrade It is possible to upgrade an existing Standard Mk.7 E.G.A. that has already been purchased. The E.G.A. is required to be returned to either Autoflame USA or Autoflame UK so that it can be reprogrammed During the C.E.M.S. upgrade, the latest software upgrade will be installed Any 2Gb SD cards will be replaced with 4Gb cards (if required) If the E.G.A.’s are operating with a Mk.7 D.T.I., an additional wiring link is required from the E.G.A.’s to the D.T.I.

13 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S. Auditing with the Mk.7 D.T.I. To enable the Continuous Emissions Monitoring Software on the Mk.7 D.T.I., an additional data link is required between each E.G.A. due to the increase of data being supplied from the E.G.A.

14 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com E.P.A. Approved Mk.7 E.G.A. The E.P.A. approved E.G.A. meets all requirements set by the Environmental Protection Agency. The E.P.A. E.G.A. Includes all software from the C.E.M.S. package, but also includes: Additional back box enabling ability to self-calibrate sensors every 24 hours 6 Connectors added to the bottom of the E.G.A., so that 6 different span gas bottles can be added for self-calibration purposes Heated Sample Line to maintain Exhaust Gas temperature during sampling Quick connect H.S.L. fitting on the top of the E.G.A.

15 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Self Calibration The E.P.A. E.G.A. self calibration process occurs once every 24 hours. During this process, the cells are each recalibrated using a zero value, and a span value. The following configuration options are available: Span gas selection with gas volume configuration Customisable timings for delay, sample and purge of each span gas Ranging of 4-20mA signal from fuel flow meter to maximise accuracy H.S.L. operating ranges configuration Additionally, the E.P.A. E.G.A. has the following information: Cell A2D logging over 365 samples (i.e. a years data at 24 hour self- calibration intervals) Graph indicating remaining life and accuracy of each cell

16 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Self Calibration Screenshots

17 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Span Gas Setup Screenshots

18 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Cell Degradation Screenshots

19 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Cell Degradation Screenshots

20 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Cell Degradation Screenshots

21 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Heated Sample Line (HSL) Requirement from the E.P.A. and MCERTs E.G.A.’s. The Autoflame Heated Sample Line maintains the exhaust gas temperature until the gases enter the E.G.A.. Gases are kept in a gaseous state. The HSL operates by using a PI loop The P band can be set by using the E.G.A. configuration options

22 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com

23 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com

24 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com MCERTs Approved E.G.A. The MCERTs approved E.G.A. contains all software that is included in the C.E.M.S. & E.P.A. E.G.A.. The MCERTs E.G.A. also requires a temperature calibration of each cell installed in the unit (provided as an additional temperature calibration code) Changes in ambient temperature cause very slight changes to exhaust gas readings. To compensate for this, each MCERTs cell board is temperature calibrated.

25 New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com Thank you for listening


Download ppt "New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers www.autoflame.com C.E.M.S., MCERTs."

Similar presentations


Ads by Google