Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum July.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-effected UES Measures Regional Technical Forum March 20, 2013.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
SEEM 94 Calibration to Single Family RBSA Data Regional Technical Forum January 23, 2013 Analysis Performed ByAdam Hadley Cursory Reviews By Tom Eckman,
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Standard Information Workbook Update Regional Technical Forum May 21, 2013.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Windows and Insulation RTF November 2, 2010.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Ben Larson 28 September th Avenue NE, Seattle, WA (206) Fax: (206)
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
1 Proposed Revisions to Deemed Savings Input Assumptions for PTCS Duct Sealing and Heat Pump Efficiency Upgrades and Duct Sealing, Commissioning and Controls.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Goodbye, “Last Measure In” Hello, “Option X”? Staff Proposal for how to deal with the last measure in conundrum Regional Technical Forum October 15, 2013.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
Direct Use of Natural Gas Status of Analysis Staff Analysis Today’s Agenda: Review of Major Analytical Input Assumptions Present Preliminary Results (Not.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
1 Proposed Energy Star New Homes Deemed Savings – Interior Ducts & HVAC April 10, 2007.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF Meeting Regional Technical Forum September 16, 2014

Ultimate Goal: Decisions 2 For Example: “I _______ move the RTF: Adopt the updated savings and costs for Single Family Weatherization UES measures as proposed, and set measure status and category as follows: – Attic Insulation: Status = Active, Category = Proven – Wall Insulation: Status = Active, Category = Proven – Floor Insulation: Status = Active, Category = Proven – Window Retrofit: Status = Active, Category = Proven – Window Upgrades: Status = Active, Category = Proven – Infiltration Reduction: Status = Active, Category = Proven Approve Staff to (Add) / (Not add) measure identifiers to heat pump conversion measures. Adopt the updated savings and costs for Single Family HVAC UES measures as proposed, and set measure status and category as follows: – Heat Pump Upgrades: Status = Active, Category = Proven – Heat Pump Conversion from FAF: Status = (depends on decision above), Category = (depends on decision above) – DHP in Zonal Heated House: Status = (depends on decision above), Category = (depends on decision above) – Duct Sealing: Status = Under Review, Category = Proven – PTCS CC&S: Status = Under Review, Category = Planning. “ 2

Where We Left Off Today’s Agenda a b 3

1. Add Measure Identifiers to Heat Pump Conversion Measures? Slides from August Meeting: 4 4

Yes or No? 55

2. Compare to Evaluation Data Question: How do the RTF UES results compare to evaluated programs; are RTF proposed values too low? – Issues: SEEM calibration is based on an “observational” dataset (RBSA), not “experimental” (ex. Pre/Post billing analysis) The analysis has had many changes since the last version of UES’s Most proposed UES values are less than the previous UES values Plan: Compare RTF Proposed UES savings to (2) recent ETO evaluations – Note: Both studies are of gas homes; RTF UES’s need to be converted to Gas FAF RTF Existing Gas UES’s converted based on eFAF UES’s: – Uses Gas t-stat setting; – Uses forced air run patterns (high supply air temp, low run times) RTF Proposed Gas UES’s converted based on eFAF UES’s: – Uses Gas Phase I adjustments; – Uses eFAF characteristic scenarios; – Uses forced air run patterns (high supply air temp, low run times) RTF Proposed Gas UES’s converted based on HP UES’s: – Uses Gas Phase I adjustments; – Uses HP characteristic scenarios; – Uses heat pump run patterns (low supply air temp, long run times) 66

2. Compare to Evaluation Data (A) A.Clean Energy Works Oregon : – Program: Comprehensive/Whole-house Retrofits – Evaluation Provides: Whole-house Average Savings n = 240 in 2010; 391 in 2011 Analysis: PRISM-like pre/post analysis for gas heated homes – Results for the few electrically heated homes in the program weren’t conclusive Available Data: Beginning and ending R-value’s and leakage levels known for each house, along with measure square footage. Conclusion: No, RTF proposed values don’t appear to be too low, when compared to ETO evaluation data on gas heated houses. 77

8 A 8

2. Compare to Evaluation Data (B) B.Draft 2009 Existing Homes Programs Gas Impact Analysis: – Program: More Typical Weatherization (Home Energy Savers) – Evaluation provides: Whole-house savings and Average savings per measure n=7,344 sites Analysis: PRISM-like pre/post analysis for gas heated homes to estimate average household savings; and multivariate regression to estimate measure level savings Available Data: Beginning and ending R-value’s estimated using data from the 2009 time period – Conclusion: No, RTF proposed values don’t appear to be too low, when compared to ETO evaluation data on gas heated houses. 9

10 B

11 B Window starting conditions data for the ETO program were not available, so each eligible starting point is shown here. 11

Can we check this one off? 12

3a. Explain why infiltration savings went down Different Calculation Method in SEEM (see December 2011 Presentation for details) – Old Version of SEEM: Infiltration is an input Input = ACHn (CFM50 * 60 / 20 / House Volume) – New version of SEEM: Infiltration is modeled Input = CFM50 (blower door test result), Stack Height, Weather Comparison: – Modeled infiltration measure savings for each prototype in Portland 69/64, no adjustment). – Results, expressed as a ratio of SEEMnew Savings/SEEMold Savings: 1344 ft2: 43% 2200 ft2: 64% 2688 ft2: 49% Then, there are differences from SEEM Calibration and Measure Interaction adjustments… 13 Slide from August Meeting: 13

14

Can we check this one off? 15

3b. Explain “R-0” cases in more detail R-Value (h·ft 2 ·F°/Btu) Inputs for Uninsulated Components ComponentCurrentProposed Attic Wall Floor Current – R-values “hand-calibrated” to give reasonable SEEM heating energy use results from uninsulated cases Proposed – R-values based on the parallel-path method for two-dimensional assembly u-factor calculation prescribed in the ASHRAE Handbook of Fundamentals 2013 (Chapter 27 for examples) Building component and air film and space R- and U-values from Chapter 26 Both methods were used in their respective SEEM calibrations 16

Can we check this one off? 17

4. Explain Cooling and Heating Baselines for Heat Pump Conversion measures in more detail Heating Savings: Conversion to Heat Pump from FAF (w/ or w/o CAC) 18 Savings 0 Years RUL FAF Pre-Conditions Baselines (Assumes FAF has remaining life) Some % of houses would have selected HP at RUL FAF : Some % of houses would have selected FAF at RUL FAF : Savings 0 Years RUL FAF Current Practice Baselines (Assumes FAF is at the end of its useful life) Some % of houses would have selected FAF without the program: Savings 0 Years Some % of houses would have selected HP without the program: Savings 0 Years RTF has previously assumed pre- conditions baseline, with 100% of houses “would have” selected FAF at RUL FAF. (Note savings are the same if we use current practice baseline where 100% select FAF.) 18

4. Explain Cooling and Heating Baselines for Heat Pump Conversion measures in more detail Cooling Savings: Conversion to Heat Pump from FAF (w/CAC) 19 Savings 0 Years RUL CAC Pre-Conditions Baselines (Assumes CAC has remaining life) Some % of houses would have selected FAF w/o CAC at RUL CAC : Some % of houses (most) would have selected HP or CAC at RUL CAC : Savings 0 Years RUL CAC Current Practice Baselines (Assumes CAC is at the end of its useful life) Some % of houses (most) would have selected HP or CAC without the program: Savings 0 Years Some % of houses would have selected FAF w/o CAC without the program: Savings 0 Years And they might, or might not add cooling later: Cooling No Cooling And they might, or might not add cooling later: Cooling No Cooling RTF has previously assumed current practice baseline, with 100% of houses “would have” selected CAC (or HP) without the program. 19

4. Explain Cooling and Heating Baselines for Heat Pump Conversion measures in more detail Cooling Savings: Conversion to Heat Pump from FAF (w/o CAC) 20 Savings 0 Years RUL FAF Pre-Conditions Baselines (Assumes FAF has remaining life) Some % of houses would have selected HP or CAC at RUL FAF : Some % of houses would have selected no CAC at RUL FAF : Savings 0 Years RUL FAF Current Practice Baselines (Assumes FAF is at the end of its useful life) Some % of houses would not have chosen cooling: Savings 0 Years Some % of houses would have selected a HP without the program: Savings 0 Years RTF has previously assumed current practice baseline, with 100% of houses “would not have” chosen cooling without the program. Recently, for DHP’s, the RTF added in the “but might add cooling later” assumption. (Note that we’ve taken a shortcut in the calculation by using the average cooling saturation over a 15-year period.) But they might add cooling later: Cooling No Cooling Average of cooling and no cooling Simplification 20

Can we check this one off? 21

5. Revisit Window Cost Estimates (Costs are per ft 2, in 2006$’s) MeasureProposed Costs Data SourceCurrent SIW Costs Previous SIW Costs BaselineEfficient ExistingU-0.30$18.51ETO Program Data$20.87$20.61 U-0.35U-0.30$1.13ETO Study & PNNL Study *$1.65$0.89 U-0.35U-0.22$4.42ETO Study & PNNL Study *$6.58$ ETO Program Data – Invoices from 1399 window retrofits – Lower quartile used here to remove improvements unrelated to efficiency ETO Study: “Residential Windows Market Research Report” (2014) – Survey looking at Dealer costs of different u-value window upgrades $0.70 for U-0.35 to U-0.30 $2.76 for U-0.35 to U-0.22 PNNL Study: “Highly Insulating Windows Volume Purchase Program” (2013) – Retail incremental cost from U-0.30 to U $1.42 to $5.19, average is $3.29 * Calculations: – ETO dealer cost of U-0.30 to U-0.22: $2.76-$0.70 = $2.06 – Dealer Markup = $3.29/$2.06 – 1 = 60% – Retail Costs U-0.35 to U-0.30: $0.70 * (1+60%) = $1.13 U-0.35 to U-0.22: $2.76 * (1+60%) = $

Can we check this one off? 23

… One More Issue Houses with DHP’s have very similar savings to houses with Zonal heating systems – Staff does not believe the differences are meaningful We’re not sure whether the differences are real, and/or an outcome of merging the DHP calibration to the Zonal/ASHP calibration For Wx measures, the staff proposal is to use Zonal savings for both Zonal and DHP houses – This assumes for DHP houses, zonal electric is (mostly) the marginal heating system We also expect there to be some temperature takeback with the DHP (i.e. higher t-stat setting) Does the RTF agree with the Staff Proposal? 24

Next Steps Decisions? And/Or More white-board issues for a future meeting? 25