B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Commercial Windows and Insulation Ryan Firestone, Wayne Leonard, and Danielle Gidding January,

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Modeling Multifamily Heating Energy Use Can SEEM be used, or do we need to use a multi- zone model? Regional Technical Forum January 17, 2011.
eQuest Quick Energy Simulation Tool
Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
1 Residential Weatherization Calculator Deriving Realistic Savings Estimates for the “Uninsulated” House.
“Do not take anyone’s advice as to how this building should be assembled.”
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Residential New Construction (NC): Slab Insulation UES Measure Update Regional Technical Forum March 18, 2014.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
The House as a System 1. Air Temperature and Water Vapor.
Lecture 7: Building Modeling Questions Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract to the National.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Intermediate Math WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Managed by UT-Battelle for the Department of Energy Weatherization Assistant: What’s New in Versions 8.4 and 8.5 Mark Ternes Mike Gettings Oak Ridge National.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
DUCT EFFICIENCY AND HEAT PUMP PERFORMANCE Paul Francisco David Baylon Ecotope, Inc.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Multifamily Air Sealing Program Bobbi Wilhelm/John Forde Implementation & Evaluation protocols March 20, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
Michael Logsdon, Ben Larson, David Baylon 13 December th Avenue NE, Seattle, WA (206)
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Building Simulation. BMEABMEA uilding odeling nergy nalysis.
CALRES Update Phase 1 Progress Report April 22, 2009 Bruce Wilcox Phil Niles Ken Nittler.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Windows and Insulation RTF November 2, 2010.
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
1 Proposed Revisions to Deemed Savings Input Assumptions for PTCS Duct Sealing and Heat Pump Efficiency Upgrades and Duct Sealing, Commissioning and Controls.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Goodbye, “Last Measure In” Hello, “Option X”? Staff Proposal for how to deal with the last measure in conundrum Regional Technical Forum October 15, 2013.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Northwest Power and Conservation Council New Commercial Building Program Quest Presentation, Discussion and Decision of Proposed Approach to Estimating.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Northwest Power and Conservation Council Small Office Savings Analysis RTF August 30, 2007.
Northwest Power Planning Council Residential Space Conditioning Conservation Resource Assessment Overview of Analytical Process and Major Assumptions January.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Presentation transcript:

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Commercial Windows and Insulation Ryan Firestone, Wayne Leonard, and Danielle Gidding January, 2011

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 2 The Plan for Commercial Weatherization  Goal Approval of provisionally deemed measures and research plan  November RTF Conclusions – Deemed savings will require rigorous modeling approach and narrowly defined measures SEEM may be appropriate for residential-type construction eQUEST/DOE2 would be an appropriate platform for larger more complicated buildings.  Today  Review current deemed measures  Building characterization  Model Calibration  Savings results and cost effectiveness

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 3 Subcommittee Review  Subcommittee Meeting  Thursday, January 27 th  Attendees: Adam Hadley, Ryan Firestone, Danielle Gidding, Wayne Leonard, Mira Vowels, Adam Hadley, Tim Steele, Ray Hartwell, Irfan Rehmanji, Sheree Willhigte, Eric Boyer, Ryan Fedie (3pm), Carrie Nelson, Lauren Gage  Topics discussed  Review of model inputs  Infiltration credit  Ordering of model inputs (first in, last in)  Measure Costs  Internal gains  Recommendation  Provisionally deem with research plan

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Changes in Response to Subcommittee Meeting  Reduced HVAC equipment size (sized to 40° ∆T, based on whole building UA)  Subtracted window area from wall area  Confirmed that ducts are in crawl space for crawl space model  Confirmed that the “no insulation” cases are the same values as the residential analysis Allows for minimal insulation existing  Adjust SHG for windows to match residential analysis  Adjust ACH from 1.72 to 0.75 Consider two windows cases: one with no ACH change, one with a 0.2 cfm/sq ft reduction

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Current Deemed Commercial Window Measures 5

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Current Deemed Commercial Insulation Measures 6  Current PTR savings and cost.  Lifetime reduced to 20 years.  Resulting 6th Plan cost effectiveness

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 7 Residential-type Construction Proposed Measures  “Residential-type”  Up to 5,000 sq. ft.  Wood frame and wood exterior  Measures  Windows, Shop-built – Single Pane to U0.30 (Energy Star)  Windows, Site-built – Single Pane to U0.30  Attic Insulation– R0 to R38  Walls Insulation– R0 to R11  Underfloor Insulation– R0 to R30  Slab on Grade Perimeter – R0 to R10

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 8 Commercial Weatherization Methodology 1) Characterize residential type commercial buildings CBSA Fill in data gaps as necessary – CA CEUS (for non-HVAC EUI) 2) Identify appropriate modeling platform SEEM, for residential-type construction 3) Calibrate model to match annual energy use intensities non-HVAC EUI, whole building EUI, and monthly loads Adjust HVAC setpoints and schedules, infiltration, heat gain 4) Define measure and base cases “last-in” assumption – base case is all measures in and sealed ducts “first-in” assumption – base case is no insulation, single pane windows, imperfect ducts 5) Define measure identifiers and weighting Location – Portland, Seattle, Boise, Spokane, Kalispell Building size – {1,500 ft 2, 3,000 ft 2, 5,000 ft 2 } Heating type – {electric resistance, heat pump ( 5 control strategies)} 6) Results SEEM results, 6 th Plan costs, ProCost

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 9 SEEM Analysis  Availability of established, easy to use simulation (SEEM) for analysis  Examine effect of building size, heating type, and measure ordering on savings  RTF familiarity  Relatively inexpensive to conduct analysis with  Good first run of methodology  Appropriate for residential-type construction  Limitations  schedule  internal loads  weekend/weekday distinction  construction type  thermal mass of walls  Limitations of current deemed analysis: EZSim, based only on 1,100 ft 2 building models, resistance heat

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 10 Building Characterization  SEEM applicability  wood frame/wood surface buildings  under 5,000 sq. ft.  Heating  electric resistance  heat pump (use battery of control strategies and weighting from RTF residential analyses)  Business type  office, retail (majority of small wood buildings can be characterized as one of these)

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N  ≤5,000 sq ft, wood, office and retail  Not much significant difference between small office and small retail  EUI Estimation Model: For same size buildings, no statistically significant difference in EUI 11 CBSA Building Characterization

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N  CA CEUS EUIs (kWh/sq ft/year), all-electric buildings 12 Non-HVAC EUI Building Characterization

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 13 Model Calibration  Consider  CBSA building characteristics  CBSA load profiles  CBSA EUI (whole building)  CA CEUS EUI (non-HVAC)  Calibration Levers  Space conditioning setpoints and schedules  R-values (walls, ceiling)  Air changes per hour

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 14 Model Calibration Occupancy Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 15 Model Calibration Equipment Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 16 Model Calibration Duct Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 17 Model Calibration – Envelope Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 18 Model Calibration – Foundation Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 19 Model Calibration Infiltration Parameters

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 20 Analysis  Location  {Boise, Kalispell, Missoula, Portland, Seattle, Spokane} – weighted averages for each heating zone  Building Size  {1,500 ft 2, 3,000 ft 2, 4,500 ft 2 }  Heating Type  {resistance, heat pump}  Use weighted average of residential battery of controls for heat pump  Measure Order  Last measure in  First measure in

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 21 Additional Details  Two window measures models 1.ACH is constant (0.75) 2.ACH reduced by window measure Windows from 0.5 cfm/sq ft to 0.3 cfm/sq ft (ACH 0.49 to 0.60)  Two baseline models:  Slab on grade – used for all measures except underfloor  Crawlspace – used for underfloor insulation measure.  Ducts moved from attic to crawlspace

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 22 Analysis – Weighting of Savings

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 23 Measure Ordering  Last-in analysis - upgrade calibrated model to fully retrofitted  Perfect ducts  Windows - U0.30  Walls - R11  Attic - R38  Underfloor - R30 (separate model with crawlspace)  Perimeter – R10  First in analysis – downgrade calibrated model  Windows – U0.90 (single pane)  No insulation

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N First/Last-In Analysis for Commercial Weatherization  Last Measure In  Most conservative savings results  Low savings are a potential programmatic barrier to achieving savings  Not representative of actual commercial building savings  Likely that converted houses not fully retrofitted  Many EE measures not offered in small commercial to double count savings  First-in analysis done to compare savings results  Requesting input from subcommittee on input parameter values and first/last in assumptions

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 25 Last-In Analysis – Energy Savings

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 26 First-In Analysis – Energy Savings

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 27 Comparison Analysis – Last In savings as a percentage of First In savings

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 28 Analysis – Cost and Lifetime  Cost  Lifetime – 20 years to account for commercial building turnover and renovation (40 for residential windows and insulation)

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 29 Cost Effectiveness  6 th Plan ProCost TRC B/C Ratio  Heating and cooling savings disaggregated to apply different load shapes in ProCost (CommHeat, Comm Cool)  Values in pink have a cost-effectiveness greater than or equal to one. Last In First In

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 30 Sensitivity – Internal Gains  Last-in total savings (heating and cooling) for 50%, 100%, and 200% of base case internal gains 50% 100% 200%

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 31 Sensitivity – Internal Gains  Last-in TRC B/C for 50%, 100%, and 200% of base case internal gains 50% 100% 200%

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Measure Summary 32

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Measure Summary 33

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Measure Summary 34

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Measure Summary 35

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Proposal 36  Provisionally Deem Measures (2 year sunset date)  Windows, Shop-built – Single Pane to U0.30 (Energy Star)  Option 1) with ACH reduction  Option 2) without ACH reduction  Windows, Site-built – Single Pane to U0.30  Attic Insulation– R0 to R38  Walls Insulation– R0 to R11  Underfloor Insulation– R0 to R30  Slab on Grade Perimeter – R0 to R10

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Proposal Cont. 37  Measure ordering  Option 1: Last-In  Option 2: First In  Option 3: Intermediate  Eligible to all “Residential-type” commercial buildings  Up to 5,000 sq. ft.  Wood frame and wood exterior  Heating: electric resistance or heat pump  Research Plan for Provisional Deeming

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Research Plan based on Subcommittee Comments 38  Infiltration Levels  Question: What are infiltration levels after window installation?  Research:  Billing history analysis for heating and non-heating loads  Post-installation blower door testing on sample of retrofitted buildings  Insulation Baseline for Windows  Question: what is baseline insulation in buildings for attic and floors?  Research:  Collect data during installation of baseline insulation  Internal Gains  Question: Do buildings have high internal gains?  Research:  Collect business type information from program participants

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Back Up Slides

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Detailed Measure TRC – First In

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Detailed Measure TRC – Last In