GSM Communication The Future of Alarm Communication

Slides:



Advertisements
Similar presentations
SCW9057 Key Features/Benefits
Advertisements

Welcome to the Radionet Monitoring Secure-Com Presentation.
GS3055-I Installation Process
Keypad / Display Keypad/Display Mounting 6 wire shielded cable 10’ length 3 twisted pairs Keypad Three function keys Four directions.
Arctic IEC-104 Gateway Jari Lahti, CTO.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
Networking By: Matt Motl… Programmer Brent Everson… Programming Mentor.
GS3055-I GSM Universal Wireless Alarm Communicator
Do’s and Dont’s - How to Prevent Troubles iConnect / CommPact
7847i Internet Communication Module
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
KX-NS1000 Initial Set Up For step by step : 16 May,
11 TROUBLESHOOTING Chapter 12. Chapter 12: TROUBLESHOOTING2 OVERVIEW  Determine whether a network communications problem is related to TCP/IP.  Understand.
1 Fox Valley Fire & Safety’s Wireless Radio Network Our customers experience reduced monitoring costs; normally 25% or more. Eliminates expensive phone.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
The Comfort System Product Presentation The Intelligent Home System.
6 February LAN-50/500 Ethernet Communication.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Cisco Confidential 1 © 2011 Cisco and/or its affiliates. All rights reserved.
Vista-21iP Control Panel WebCast
ONYX Product Overview.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
Lynx Series Lynx Plus LynxR-2 LynxR-EN LynxR-i LynxR-iSIA
IP Momentum Confidential Polycom IP Phone Provisioning Guide—Sylantro- hosted Service Release /06/05.
Advanced Networking for DVRs
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Ch 8-3 Working with domains and Active Directory.
Ch. 5 – Access Points. Overview Access Point Connection.
GS2065/TL265GS Product Technical Training (International version)
Burglar & Fire Alarm Basics
GS2060/TL260GS Product Technical Training
Please Dial in, class will begin shortly
Computer Networking Part 1 CS 1 Rick Graziani Cabrillo College Fall 2005.
TouchCenter.
AVS Audio Verification System
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
Single Loop Analogue addressable fire control Panel
Managing Windows Server 2008 R2 Lesson 2. Objectives.
DSL-2544N Dual Band Wireless N600 Gigabit ADSL2+ Modem Router
EMerge Browser Managed Security Platform Module 3: Startup eMerge Certification Course  Physical connection  TCP/IP Characteristics of PC  Initial connection.
1. Insert the Resource CD into your CD-ROM drive, click Start and choose Run. In the field that appears, enter F:\XXX\Setup.exe (if “F” is the letter of.
T-Link II Secure Internet Alarm Communication. Product Goals… High level encryption Software upgrades via network Universal compatibility Non-Static IP.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Paradox Communication Solution GPRS / GSM
GS3055-I Installation Process
GPRS functionality overview in Horner OCS. GPRS functionality – Peer to Peer communication over GPRS – CSCAPE connectivity over GPRS – Data exchange using.
1 ARC reporting ARCCerny Verze INTERNET ARC events reporting Control panel 3. PSTN Telephone network - CID 1. GSM network – GPRS IP CID.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
LOGO Yeastar Technology Co., Ltd. Enterprise Communication.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
SNG via Webinar. Where’s Webinar??  Double click Aflac 2000 folder  Highlight “SNGWebCommunicator”  Right Click and “Send To - Desktop”
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
PIM Technical Training, December 2011 Brian Whitcomb 12/20/2011 Call-in Number = Pass code =
Run the on your PC to start the firmware configuration process Run IP Config Tool.
TERMINAL REGISTRATION Section Full Automatic Mode2. Extension Input Mode3. Manual Mode UT seriesYesNoYes NT3xx / NT265Yes NT700No Yes General.
Windows Vista Configuration MCTS : Advanced Networking.
SMS module HDL-MGSM.431.
Advisor Advanced Release FW120.
GEM-P1632 Hybrid Control Communicator
Hardware Appliance Installation and Configuration
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
How to install a WISE-4051 Device Presented By: Mark Brown
Presentation transcript:

GSM Communication The Future of Alarm Communication

What is GSM? Global System for Mobile Communications Developed in 1990s One of the leading digital cellular networks AT&T network in the U.S. Rogers network in Canada Most popular standard for mobile phones in the world. Approximately 70% of the world’s market Open standard with roaming capability

Two communication paths: GPRS and SMS General Packet Radio Service Always On connection Typically faster than SMS Real-time confirmation Higher bandwidth capacity Supports downloading SMS Short Message Service Store and forward communication Sent via SMS Center Less bandwidth capacity No downloading support Both signaling and speech channels are digital. Higher digital voice quality and text messaging

Honeywell GSM Radio Offering Uses GPRS for reliable transmission of alarm signals Back-up reporting with SMS Contact ID or ADEMCO Hi Speed Power Supply and battery included Panel downloading supported 6 HW zone inputs (seven zones) Tampered enclosure Fault Relay output Future Proof Design Protects Your Business

Honeywell i-GSM Radio Offering Uses an existing internet connection for reliable transmission of alarm signals Back-up reporting with GPRS or SMS Contact ID or ADEMCO Hi Speed Power Supply and battery included Panel downloading supported 6 HW zone inputs (seven zones) Tampered enclosure Fault Relay output

Honeywell GSMCF/iGSMCF Radio Offering Will replace the 7835CF, 7845CF and 7845CZF; but does not replace the 7720ULF or 7720ULFPLUS. This device cannot be a stand-alone communicator, although it can be a primary communicator if you have another form of communication. It is designed to replace one phone line to a fire panel. IGSMCF This radio has been ETL approved for primary commercial fire use. This radio will replace the 7835CF, 7845CF, 7845CZF, 7720ULF and 7720ULFPLUS. This device is a stand-alone communicator, designed to replace both phone lines to a fire panel. The GSMCF and IGSMCF both come in a red fire resistant can and includes an externally mounted antenna (3dB gain).

GSM Communication Installation Procedures

Installation Procedures Installation of a GSM radio will consist of a few steps: Activating the SIM card. Finding a suitable mounting location with adequate signal strength. Wiring to control panel. Programming and Registration

Activating the SIM Card The SIM card on the GSM device you are installing must be activated prior to completing the registration process. You will not have any signal strength indication on your GSM radio prior to SIM activation. The SIM card can be activated up to thirty days prior to registration. You may set up registration at the time of activation. If the radio is not registered to an account within thirty days, the SIM will be automatically deactivated by Alarmnet.

Activating the SIM Card There are three ways to activate a SIM card: Log on to Alarmnet Direct website and enter MAC ID and CRC information https://services.alarmnet.com/alarmnetdirect/ Contact your Central Station Call Alarmnet SIM activation at 800-222-6525 Select option 1 for Technical Support, then press 1 for Alarmnet GSM device activation. You must have the MAC ID and CRC to activate the SIM. It will take from several minutes to a few hours to activate the SIM.

Where can I get the Mac ID and CRC?

Check Signal Strength 9VAC 15VA NOTE: It is extremely important that you select a suitable mounting location that allows for adequate signal strength!!!

Wiring for ECP and 4204 modes 9VAC 15VA NOTE: AC Power must be applied on 1 and 2.

Wiring for ECP on a LynxR-i The LynxR-I series panels provide the primary and backup power for the GSM radio. Do Not Connect the 7845GSM internal battery or the GSM power transformer. NOTE: DC Power is supplied from LynxR-i panel.

Wiring Zone 1 input to a LynxR trigger output 9VAC 15VA Program Trigger as V- and enable Lynx Panic NOTE: AC Power must be applied to terminals 1 and 2 on 7845GSM.

Wiring Zone Input for Bell (or positive voltage) output

Zone input using NO/NC contact with EOLR Supervision

GSM Communication Programming and Registration

Programming and Registration There are several options to program and register the GSM radio: Log on to Alarmnet Direct website and enter the appropriate radio and account information https://services.alarmnet.com/alarmnetdirect/ Program and register using the 7720p program tool. Contact your Central Station Call Alarmnet Registration at 800-222-6525 Select option 1 for Technical Support, then press 1 for Alarmnet GSM device registration. You must have an account number (provided by your Central Station) and be able to provide radio MAC and CRC to proceed with registration.

Programming: Using the 7720p You must have AC power on terminals 1 and 2 for 7720p to work.

Programming Basics: Using the 7720p Plug in 7720P programmer and press Enter key Press Enter to accept entries Use the up/down arrow keys to scroll through the programming questions without changing any values. Perform a Shift function by pressing Shift key and then the appropriate key. Strt Prog Mode? Y/N_ Press Shift & Y

Programming Options Enter Password Program 7845? Y/N Press Shift & Y Create Password? Y/N

Programming Options Options: Device Mode? ECP Primary City ID? (??) Zone Triggers 4204 EMU 2 4204s (Use the space key to scroll through options) Device Mode? ECP Primary City ID? (??) Acct info provided by your Central Station Primary CS ID? (??) Primary Sub ID? (????)

Programming Options 2ND CS Y/N? 2ND City ID? (??) 2ND CS ID? (??) Option to use 2nd CS reporting only available on High-End panels (polling loop panels) 2ND City ID? (??) 2ND CS ID? (??) 2ND Sub ID? (????)

Programming Options Device Address (03) Enable DW Y/N (N) High-end Panels Only (polling loop) If Yes Direct Wire Address (28)

Programming Mode Supervision Options are: 24 hours Old Alarm Time None 24 Hours 30 days Note: This feature does NOT enable a test report to be sent to the Central Station Old Alarm Time (10 Minutes) GSM Flt Time (60 mins) Flt Rel On Y/N (N)

Programming Mode Pwr Loss Rpt (Y/N) (Y) 1-3 hours of loss Disable these reports if installing on the LynxR-I (ECP) 1-3 hours of loss Low Bat Rpt (Y/N) (Y) Tamper Rpt (Y/N) (Y)

Programming Mode Zones 6 & 7 are available in ECP mode Enable Zn 6 (Y/N) (N) Zn 6 Trigger Type (V+) Restore Zn 6 (Y/N) (N) Invert Zn 6 (Y/N) (N) Delay Zn 6 (secs) (00) Repeat for zone 7 if required

Zone Mode When the GSM is programmed for zone mode, there are six input zones available. The first zone input (TB1, pin 5) can detect a pulsed signal (reported as zone 1) or a steady signal (reported as zone 2). When using zone trigger mode, messages are sent in ADEMCO high-speed format.

Zone Mode Programming Options Trip Inputs 1or2 w/Bell out (N) Enable this option when wiring zone 1/2 input (terminal 5) to control panel positive bell output. This will help prevent false alarms caused by supervision voltage on the bell circuit. This will also prevent the radio from causing bell circuit faults on the control panel. Note: Enabling this feature will raise the trip voltage on zones 1, 2, and 3 from 2VDC to 5VDC. This option should not be enabled with negative trigger inputs on zones 1, 2, or 3.

Zone Mode Programming Options Zn1 Trigger Type (V+) This selects the triggering method for this zone input. Options are: (V+), (V-), or (EOLR) If zone is set for (V+), the zone will report an alarm when voltage input is 2VDC-14VDC. Trigger levels above 14VDC may damage the unit and trigger levels below 2VDC may not trigger the zone. Remember: Enabling “Trip Inputs w/Bell out” increases minimum trigger requirement for zones 1, 2, and 3 to 5VDC.

Zone Mode Programming Options Zn1 Trigger Type (V+) This selects the triggering method for this zone input. Options are: (V+), (V-), or (EOLR) If the zone is set to (V-), the negative triggering voltage must be less than 1.0VDC. If the zone is set to (EOLR), the zone will report an alarm when the EOLR is removed from the zone. Recommended EOLR is 2K ohms.

Zone Mode Programming Options Restore Zn1 Y/N (Y) This enables the zone to report when it is restored. Delay Zn1 (secs) (00) This option defines any delay in reporting for this zone input (from 0 to 15 seconds). Rpt Zn1 ONLY if Armed (N) This option will disable this zone from reporting unless the conditional zone is triggered. (The conditional zone is zone 7 when radio is in zone mode.)

Zone Mode Programming Options Invert Zn2 Y/N (N) This option inverts the alarm and normal states of the zone trigger. This option is enabled only when radio is connected to a Lynx, LynxR, or LynxR-EN. This enables a silent panic alarm to be sent when a single pulse is detected on zone 1. Lynx Panic Y/N (N)

7845I-GSM Programming Options Basically the same as the previously discussed “GSM flt time.” In the event there is loss of contact with the network over the Ethernet connection, enter the time delay before the 7845i-GSM notifies the Central Station of the problem. IP failure will always be reported as “Primary Communication Path Failure” IP Flt Time (60 mins) Programming options are: “Neither Fault” or “Both IP and GSM Faults.” If “Both IP and GSM Faults” is selected, the device will notify the control panel (via ECP bus or GSM fault relay) if both communication paths fail. Notify Panel Of (Neither Fault)_

7845I-GSM Programming Options If enabled, all messages (including AlarmNet network supervisory messages) are sent over GSM network in the event of an internet failure. If disabled, all messages (except AlarmNet network supervisory messages) are sent over GSM network in the event of an internet failure. GSM Rollover Y/N (Y)_ If enabled, the 7845i-GSM sends a supervision ping over the GSM network once a day to verify backup communication path. A “secondary communication path loss” message is generated if the message is not successfully delivered. GSM 24Hr Tst Y/N (N)_

7845I-GSM Programming Options Use DHCP Y/N (Y)_ DHCP dynamically allocates the IP addresses (recommended). If you select “No,” then you must program the following fixed (static) IP addresses: NIC IP Address: 255.255.255.255_ Gateway IP Addr: 255.255.255.255_ Subnet Mask: 255.255.255.255_ DNS Server IP Addr: 255.255.255.255_

7845I-GSM Programming Options Enable Pwr Save (Y)_ For 24 UL battery backup requirement, this feature must be enabled, or the unit must be powered by an appropriate UL listed UPS. What does it do? If the feature is enabled, the communicator’s NIC card will power down and will power up every 20 seconds to send a test ping (to test internet path) then power down again. The NIC will also power up anytime the unit needs to transmit information over the internet. If connectivity problems occur with certain routers or switches, disable this option.

GSM Communication Registering the GSM New and Replacement

New Registration (Radio on New Account) After exiting programming mode on the 7720p, you may register the radio by hitting the Shift key, then the “up” arrow. Shift Registering… Registration Success

Replacement Registration When registering a replacement radio on an active account, a pin number must be entered. After exiting programming mode, select the “down” arrow key. You will be prompted to enter a pin. Enter PIN and hit the Enter key to proceed with registration. If replacing a C radio, enter the last four digits of the min number. If replacing a GSM with another GSM, a PIN must be generated by your Central Station. Enter PIN# Registering… Registration SUCCESS

GSM Communication Programmerless Registration: Using Alarmnet Direct

Programmerless Registration Preliminary Steps Required Before Registration Before registering, you must have the following information available: CITY number CS number RADIO SUBSCRIBER number DEVICE MODE Daily or Monthly Supervision MAC Address from 7845GSM Radio MAC CRC number from the 7845GSM Radio City number, CS number, and Radio Subscriber number is assigned by your Central Station

Programmerless Registration Steps Required to Enter Data Log into AlarmNet Direct using your user name and password. https://services.alarmnet.com/AlarmNetDirect To program a radio on a NEW account, select “Program New Device GSM/I” To replace a “C” radio with a GSM, select “Replace C Device” To replace a GSM with another GSM, select “Replace Other Device”

Programmerless Registration Enter the radio’s information CITY number CS number SUBSCRIBER number Supervision Rate MAC number CRC number Confirm the Device Mode, and if using ECP with device address 03 click Done.

Programmerless Registration AlarmNet C Replacement Enter 10 digit MIN number from old C Radio

Programmerless Registration AlarmNet GSM Replacement Enter PIN number generated by your Central Station

Programmerless Registration Important Note About Programmerless Replacements! The PIN is only transferred to the 7845GSM device on the first data transfer attempt. If your device fails to register, take the following steps using AlarmNet Direct. Delete the account from “Show Programmed Devices”. Add the account back using “Replace C” or “Replace Other Device”. From the “Show Programmed Devices” page, execute the SEND DATA command and get confirmation of the data transfer by refreshing the page. After current date and time are showing in the “Transferred” column, execute the “Register” command. Following these steps will ensure the PIN is transferred to the device. Remember, If the device fails to register the first time, the PIN will be reset to FFFF and will not be accepted by the AlarmNet servers.

Programmerless Registration Selecting “Done” sets programming to default values, which is ECP Mode, Device Address 03. If the installation requires you to change any programming option from the default value, select “Advanced Programming”.

Programmerless Registration Screenshot of “Advanced Programming” screen

Programmerless Registration Screenshot of “Advanced Programming” screen

Programmerless Registration Screenshot of “Advanced Programming” screen

Programmerless Registration

Programmerless Registration On site click the Tamper Switch 3 times. The green (status) and yellow (message) LED’s on the top left should start flashing together.

GSM Communication IP Downloading

IP Downloading Support Panels that can be downloaded via GSM

IP Downloading Support Panels that can be downloaded via GSM

Vista-20P and LynxR-i The Vista-20P and LynxR-I communicates with the 7845GSM over the ECP (keypad) bus. To setup the control panel, do the following: Connect the 7845GSM module to the control panel’s ECP (keypad) terminals as you would a keypad. Enable the 7845GSM as a Long Range Radio in the control panel to enable alarm reporting and module supervision. Vista - *29 = 1 LynxR-I - *55 = 1 Program the 7845GSM and set the ECP address to 3. Register the 7845GSM with AlarmNet. The module must be registered before downloading or alarm reporting can take place.

Vista-128/250BP and Vista-128/250FBP To set up the control panel, do the following: Connect the 7845GSM module to the control panel’s ECP (keypad) terminals as you would a keypad. Program the 7845GSM as required using the 7720P programmer. (To do this, temporarily disconnect the RJ11 from the 7845GSM and plug in the programmer). Remember to program: Question 13 (ANI ECP Address) with the same address programmed in Step 4. Two additional programming questions have been added for direct wire downloading over IP: Question 14 (Enable DW) to enable direct wire downloading; and Question 15 (Direct Wire Address), to tell the 7845GSM what keypad address the 7845GSM is going to use for direct wire downloading (same address as entered in Step 5). Connect the trigger cable between the control panel trigger connector and the 7845GSM (RJ11 connection). Enable an address for the 7845GSM as a Long Range Radio (LRR) in the control panel’s Device Programming Mode (*93). This enables the 7845GSM on the control panel.

Vista-128/250BP and Vista-128/250FBP Enable a second address for the 7845GSM as a keypad in the control panel’s Device Programming Mode (*93). This enables the control panel to perform downloading over IP. Do not connect an actual keypad or any other device at this address. Register the 7845GSM with AlarmNet. The module must be registered before downloading or alarm reporting can take place.

Direct Wire Connections

GSM Communication Diagnostics

Exterior L.E.D. Status

Mode and Status Indicator Switch LED 4 not used on 7845GSM

Mode and Status Indicator Switch Remember: LED 4 not used on 7845GSM Connected To Web

7845i-GSM Network Connectivity Display

7845GSM ECP Keypad Display Status Codes Note: You can only display Status Codes on an alpha keypad.

7845i-GSM ECP Keypad Display Status Codes Note: You can only display Status Codes on an alpha keypad.

7845GSM Central Station Messages

7845i-GSM Central Station Messages

Honeywell Security support e-mail: mywebtech@honeywell.com http://www.security.honeywell.com/hsce/ and click on MyWebTech User name: honeywell Password: support99 Honeywell Security support e-mail: mywebtech@honeywell.com