1 Puissant Panel User Training Esc.

2 09:11:35 ACTIVE 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Puissant Panel Indications Esc. SUPPLY HEALTHY (GREEN) illuminates whilst both battery and mains supply are present. FIRE (RED) illuminates when a fire conditions is present. MORE DATA (AMBER) illuminates when the display area is full and more information is available. SYSTEM FAULT (AMBER) illuminates when a system fault (processor failure) has occurred. SYSTEM FAULT (AMBER) illuminates when a system fault (processor failure) has occurred. TEST (AMBER) illuminates when the panel is in any of its test modes. DISABLED (AMBER) illuminates when part of the system is isolated. DISABLED (AMBER) illuminates when part of the system is isolated. GENERAL FAULT (AMBER) illuminates when any fault condition is present. ALERT (AMBER) illuminates when an alert condition is present. DELAY ON (AMBER) illuminates when the alarm transmission delay feature is enabled. DELAY ON (AMBER) illuminates when the alarm transmission delay feature is enabled. ACCEPT (AMBER) illuminates when alarms are activated and may be silenced. ACCEPT (AMBER) illuminates when alarms are activated and may be silenced. This LCD alpha numeric text display provides details of all conditions.

3 09:11:35 ACTIVE 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Puissant Panel Controls Esc. SILENCE ALARMS Operational only when a fire/evacuate condition is present. Operation will silence audible alarms, change internal buzzer tone and cause the RED fire LED to change to a constant illumination. CYCLE DISPLAY Operational only when display area is full and more information is available. EVACUATE causes the alarm circuits to energise and the internal buzzer to operate. To cancel, the system must be silenced & reset in the normal manner. Operation of this switch causes all LEDs to illuminate and internal buzzer to sound. Operation will clear a fault message from the LCD display after a fault condition has cleared. Silences the fault buzzer when an active fault is present. Silences the fault buzzer when an active fault is present. SYSTEM RESET Operational only during a fire/evacuate condition and when the SILENCE ALARMS switch has been operated; causes the system to reset to a quiescent condition (if no alarms or faults are present). DELAY OVERRIDE Overrides the pre- programmed Night/Day alarm output delay. (Evacuate, and call points will also override the delay). Operation of the ENGINEER control prompts the user for an access code and then enables access to the engineer’s menu. TEST ALARMS Operation of this switch will cause the external sounders to operate until switch is released. * # Engineer’s functions

4 Puissant LCD Display Esc.

5 Puissant Panel in “Standby” 08:23:59 SYSTEM ACTIVE LED IndicationsUser Controls Message Display Esc. This LCD displays “System Active” or the company name. This LCD displays “System Active” or the company name. Supply Healthy LED on Supply Healthy LED on

6 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Test Display Esc. Buzzer Sounds All LEDs Steady All LEDs Steady

7 Test Alarms ALARMS TESTED 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT A B Buzzer - 3 Seconds Esc.

8 Fault 1:001 Z01 ION RMVD ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Buzzer Pulsates Esc. Flashing LED

9 Fault Cleared 1:001 Z01 ION RMVD ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. Flashing LED Steady LED

10 System Alert 1:001 Z01 ION ALERT ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Loop number Device number Zone number Type of device Device condition Esc. Steady LED Flashing LED

11 System Alert -Alert Clear 1:001 Z01 ION ALERT ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. Steady LED

12 System Alert - Clearing Display 1:001 Z01 ION ALERT ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. Steady LED

13 System Fire 1:001 Z01 ION FIRE ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Esc. Steady LED Flashing LED Loop number Device number Zone number Type of device Device condition

14 System Fire - to Silence Alarms 1:001 Z01 ION FIRE ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. Steady LED

15 System Fire - to Reset System 11:22:05 PANEL IN RESET PLEASE WAIT 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. 30 seconds to reset; then panel returns to “standby” status

16 To Evacuate from the Panel 11:20:15 *MANUAL EVACUATE * 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Esc. LEDs are flashing

17 To Evacuate from the Panel - Silencing Alarms 11:20:15 *MANUAL EVACUATE * 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Buzzer Pulsates Esc. LEDs are steady

18 To Evacuate from the Panel - to Reset System 11:22:05 PANEL IN RESET PLEASE WAIT 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Esc. 30 seconds to reset; then panel returns to “standby” status. 30 seconds to reset; then panel returns to “standby” status.

19 Multiple Events (1) 1:001 Z01 ION FIRE ROOM 6 GROUND FLOOR 1:006 Z01 BGU FIRE GROUND FLOOR EXIT 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Esc. Steady LED Flashing LED

20 Multiple Events (2) 1:001 Z01 ION FIRE ROOM 6 GROUND FLOOR 1:006 Z01 BGU FIRE GROUND FLOOR EXIT 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Esc. Flashing LED Steady LED

21 Delay Override 1:001 Z01 ION ALERT ROOM 6 GROUND FLOOR 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT Continuous Buzzer Esc. Steady LED Flashing LED

22 Engineer’s Access (1) * ENTER CODE, PRESS * 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT A C B Enter Engineer Access Code Esc.

23 Engineer’s Access (2) SELECT LEVEL 1 OPTION 1 SET TIME / DATE 2 ISOLATE DEVICE/S * NEXT PAGE # QUIT 7 0 1 4 8 # 2 5 9 * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE ALARMS CYCLE DISPLAY TEST ALARMS ENGINEER DELAY OVERRIDE EVACUATE SUPPLY HEALTHY FIRE ACCEPT DELAY ON GENERAL FAULT DISABLED TEST SYSTEM FAULT MORE DATA ALERT } Use Numbers 1 to 0, * # Esc.