Antunes Water Filtration Technologies Introduces to You:

Slides:



Advertisements
Similar presentations
Overview Presentation
Advertisements

Harnessing the energy of the sun to provide safe drinking water for the world.
Paradigm Change – New Approaches in Filtration & Pre-Filtration Improves Sustainability and Profitability Jim Phene Business Development Director.
RK-60The Ultimate Solution to Community Water Problems A Water Treatment Unit producing clean water at 60 Litres per minute safeguarded from worms, cysts,
Innovative Design for Efficient and Reliable Filtration Systems.
ULTRA VIOLET STERILISER 10Gpm – 15Gpm. Sterilight- S8Q PA 30 – 76 litres per minute S12Q PA 42 – 110 litres per minute 99.9% inactivation of even Giardia.
The Concept of the Basic Liquid
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)
© ABB Group September 1, 2014 | Slide Turbidity Systems Accurate, reliable turbidity measurement.
Microfiltration / Reverse Osmosis The 1-2 Punch for Water Treatment
ACTIVATED CARBON Granular Activated Carbon may be used for a variety of water treatment applications requiring the reduction of chlorine, tastes, and odours.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
OPEX Savings Utilizing Filtek Technology. Agenda 01 Introduction: What does Filtek Offer? 02 Why Service the Generator every 250 hours? 03 What is Filtek.
KE2 Evaporator Efficiency
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Treatment of wastewater by combination of ozonization and membrane separation Zsuzsanna László, Cecilia Hodúr.
Membrane Applications in Water Treatment
I-MBR Side-stream, in vitro MBR system for Water Treatment About i-MBR Modules PHILOSEP i-MBR is in vitro, cased and decompression type membrane modules.
ETL Multi Media Grey Water Filters and Pre Reverse Osmosis Filtration.
Slide © Water Evolution Technologies, Inc CONFIDENTIAL 1 Built on over 15 years of experience and research in providing optimized water for food.
Dr. Martin T. Auer MTU Department of Civil & Environmental Engineering Water Treatment.
Drinking Water and the Lake There are 40+ plants utilizing Lake Michigan Water Illinois, Wisconsin, Michigan, Indiana Sizes of 1 MGD to 1 BGD Designed.
Novasep Process: TangenX Tangential Flow Filtration Products
Evaluation of DWTUs Which Consist of Multiple Technologies Testing of systems which fall under multiple DWTU Standards.
Introduction to Environmental Engineering Code No. (PE389) Lec. 5 and 6.
FILTER-AG PLUS ® Automatic backwashing unit to dramatically reduce sediment and colour in rural surface water.
Sand media filtration is one of the oldest filter processes in the world. Water Tool Modular Filters have made extensive improvements to what is presently.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Water Purification Systems for Clinical Lab Prepared By Farid Khalaf.
Tel: +44 (0) Turbidity Application and Product Data.
THE BASICS of SFR Spot Free Rinse Systems - working to keep your reputation spotless  Spot Free Rinse water must have less than 40 ppm of TDS. Our preferred.
OPG WTP Performance / Trends in High Purity Water Treatment Presented at IAPWS Workshop May 11, 2009 By Gabriel Nicolaides.
REUSE–A–MUG Yellow B. Lack of access to clean water or adequate water purifying devices is a major problem 6,000 children die every day from diseases.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Volvo Group North America, LLC Reuse of Wastewater - A Manufacturer’s Experience Steve Pierett, Env.Mgr. CEM, CRM, CP EnMS-Industrial.
SPWSTAC 2006 From POU to Centralized Arsenic Treatment: A Small Water System Case Study 2006 NGWA Naturally Occurring Contaminants Conference J. Mitchell.
Unique & Superior Lubrication Technologies
World’s Best Ceramic water filters
The Original Water Purifier ‘S‘S Introducing….. Technology made simple for your most basic needs.
Sustainability through innovation in water analysis
1.Submit your Creek Survey if you haven’t already done so. 2.Which part of the water cycle is MOST responsible for polluting surface water? 3.Municipalities.
정수공학및 설계 Membrane Processes.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Austin Pure Air Independent Agent - Products and Prices 2016 UNRIVALED PURIFICATION TO 1 NANO EVEN IN OUR SMALLEST UNIT Quiet Operation The GENANO 200.
PRESENTSITS Sanitary Wastewater Concentrator. A Shortcut to Reusable Clean Water From Sanitary Wastewater!
Welcome. M/s.Sre Senthil Engineering Company, A-12, Coimbatore Private Industrial Estate, Coimbatore – Phone –
Distribution System If microorganism colonize a storage vessel, the latter then acts as a microbial reservoir and contaminates all water passing through.
Overview of HVAC Filtration
Chapter 6 Reverse Osmosis and Nanofiltration
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
1 Highland Water District CAPITAL IMPROVEMENT PLAN.
Sludge water recycling unit UFOX 10
On removing little particles with big particles
Zeosorb - The Clean Solution. AMAZING REVOLUTION!! LATEST STATE OF THE ART 3 IN 1 SOLUTIONS Zeosorb FOR YOUR WATER FILTERATION UNITS.
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
RAINMAKER and RAINMAKER Enviro
REVERSE OSMOSIS PLANTS 5-35kl/day
Engineered Water Treatment Solutions
Oxygen + Mineral Water Purifier November, 2009.
THE BEST METHOD FOR WATER FILTRATION – REVERSE OSMOSIS.
T7 – POLYPROPYLENE PLEATED CARTRIDGES
V.S..
How not to be, or get to be; GROSS!
Franke Filtration training 101
Matt Bower DWQR Risk Assessment Training 2018
Treatment – Sediment Filters
Treatment –Reverse Osmosis (Desalination)
One World Filter.
Simple and Easy Oil/Grease contaminated water clean up
Presentation transcript:

Antunes Water Filtration Technologies Introduces to You:

The Challenge: Improve the quality and safety of the water used for beverage and ice production while reducing the cost & labor requirements for maintaining the system.  Quality Assurance  Safety Assurance  Cost Assurance

The Solution: An automatic self cleaning / self optimizing filtration system utilizing proprietary Ultra-filtration technology, separating the Mechanical Filtration from the Chemical Treatment media.

T.A.P. System Total Assurance Package  Separated Mechanical (UFL) and Chemical (Carbon)  Controlled “Cost to Own”  Low Cost Carbon  SMART Controller  Self Cleaning Ultra-Filter True Backwash True Backwash  Critical Reduction of Turbidity, Cyst, Bacteria and Virus TAP-442

What’s the deal?  We feed water that has been pre- processed by our ultra-filter (.02 nomial microns) prior to our low cost, large pore, taste and odor (carbon) elements  Our carbon elements never clog…they are clean and free flowing upon replacement …only activity / effectiveness of the carbon elements has changed

TAP- 442 vs. Other Carbons  Mechanical Filtration and Chemical Treatment are separated  Lower Cost Carbon Elements  10: 1 Chemical Reduction 5 ppm to 0.5 ppm 5 ppm to 0.5 ppm .02 nominal micron mechanical filtration pore size 33 times tighter 33 times tighter.02 micron = I millionth of an inch.02 micron = I millionth of an inch  5 micron carbon pore size 10 times more open 10 times more open More surface area for chemical reduction More surface area for chemical reduction  Approx. 5 years of Data Storage  Alerts for UF and Carbon Orders and Replacement  Power Saving Features for 18 hours  Mechanical Filtration and Chemical Treatment are not separated  Higher Cost Carbon Elements  2:1 Chemical Reduction 2 ppm to 1 ppm .5 micron mechanical filtration pore size .5 micron carbon pore size  No Data Storage  No Cartridge Replacement Alerts  No Power Outage Features

Economics Antunes TAP-442 Systems Carbon Cost $60 USD for 120,000 gallons (455,000 liters) of water usage$60 USD for 120,000 gallons (455,000 liters) of water usage ANY AND ALL QUALITY OF WATERANY AND ALL QUALITY OF WATER $.0005 USD per gallon + water cost$.0005 USD per gallon + water cost Typical disposable filters $150 USD for 30,000 gallons (114,000 liters) of water usage$150 USD for 30,000 gallons (114,000 liters) of water usage Nominal water qualityNominal water quality $.0050 USD per gallon + water cost$.0050 USD per gallon + water cost

Expected Savings (based on 60K gallons (227 KL) of challenged water / year) --- $$$ based on USD --- Current 4 changes per year: $660 With TAP system: $30 Your Savings: $630 Payback in about 3 years Current 12 changes per year: $1,980 With TAP system: $30 Your Savings: $1,950 Payback in about 1 year

Smart Controller  AJA designed and manufactured automatic Smart Controller  Flushes and Optimizes automatically on pressure differential and flow rate  Detects UFL cartridge installation  Alerts operator when to order and change UFL cartridge and Carbon elements  Communication to store LAN: Can store up to 5 years of Data LED Light determines which % Remaining is displayed on Numeric Display % of Ultrafiltration Remaining: Based on Ver % of Carbon Remaining: Based on Gallons System: LED lit when in System Mode Flush/Enter Button 1: Inlet Solenoid Valve 2: Permeate Solenoid Valve 3: Drain Solenoid Valve In System Mode and Flush Program LED lit when valve closed Numeric Display LED Light determines flushing program Non-Peak Time: Does not flush during peak time When Needed: Flushes when needed even during peak time Use to arrow up and down in System Mode View Button

Data Download from Controller *Times based on 24 hour clock VER: Measurement used to Clean the Ultra Filtration Cartridge Date Peak Flow Rate Time* Flow Rate (gallons per minute) Peak Differential Pressure Time* Peak Differential Pressure Peak VER Time* Peak VER Number of Flushes Total Gallons Used 6/30/0610:50: :04: :25: /1/064:00:426.84:00: :53: /2/064:01:345.24:01:34722:49: /3/0616:44: :26:38822:19: /4/0613:59: :11: :21: /5/069:39: :40: :17: /6/0612:31: :13: :51: /7/068:37: :58: :00: /8/0610:34: :33: :00: /9/068:49:264.94:00: :00: /10/0611:49: :00: /11/069:56: :29: :00: /12/0612:31:364.40:35: :00: /13/0613:45: :11: :00: /14/064:02:106.14:02: :00: /15/0612:37: :14: :00:

Control Data Summary Typical Usage Summary Store Name Flush trigger point VER: System will flush when value hits this point1.3 Running VER: Average VER value Best VER: Value that the cartridge reaches after a flush Carbon Max gallons (New): Factory Setting Carbon Total gallons used Est remaining days of Carbon Carbon - Days in operation % Carbon Remaining61%86%90%93%83% Est. Carbon Life in yrs Gallons used for Flush % Efficiency: Water that is for consumable drinking water 98% 99%98%97%99% % UF Open 95%99% Last Data Download 10/17/0610/30/069/22/0610/30/069/20/06

Graph Created from Data

TAP Installations Westley, CA Hartford, CT

Self Cleaning 1 st Back Flush

Self Cleaning Followed by Forward Flush

Additional benefits of Cleaning Process…  Not limited to a specific gallon capacity or water quality  Short cleaning cycle at most 60 secondsat most 60 seconds  No chemicals required  Longer life for the cartridge TAP-442

Utilizes Listed UFL Product UFL- 420UFL- 440  Standard 53: Health Effects Cyst Reduction Turbidity Reduction  Standard 42 Particulate Reduction

Ultra-Filtration  A physical barrier – 0.02 nominal microns pore size means all cysts, bacteria & colloidal(s) are removed and 99+% of viruses.  Environmentally friendly – no chemicals required  Low maintenance – minimal consumables

Ultra-Filtration (UF) UF is a physical barrier

Physical Barrier against Bacteria & Viruses Bacteria, Viruses and Cysts photographed against the AFT Membrane

Ultra filtration is not new. What makes membranes different?

The Multi-Bore Membrane: Superior Technology  Low Water Waste: 98% Water Recovery 98% Water Recovery  Consistent High Quality Water Independent of changes in water Independent of changes in water  Consistent Pore Structure: Perfect barrier to microorganisms Perfect barrier to microorganisms  Allows more internal surface area  Eliminates Breakage: Combines single capillaries into one strong fiber Combines single capillaries into one strong fiber  Made of Polyether Sulfone (PES): Highly robust Highly robust Larger Internal Surface Area Consistent Pore Structure

How Multi-Bore Filtration Works

Higher Quality at Lower Cost  Ultra-Filtration produces a higher quality water for beverages than that produced by a traditional disposable submicron filter.  With our system, typical pre-filtration is not necessary for highly turbid water.  Protects systems down stream because have already removed the large particulates

TAP systems provides  A higher quality of water with Virus, Bacteria, Cyst and Chlorine reduction  Lower cost of operation Less costly consumables Less costly consumables  Less required maintenance (Serviceman in the Box)  An environmentally friendly process  High Flow 10 (38 LPM) and 5 GPM (19 LPM) systems TAP-442

What Should You Do Next?  Protect your brand Quality AssuranceQuality Assurance  Consider the potential threat of some contaminants getting into your product. Safety AssuranceSafety Assurance  Analyze the savings of using AFT / TAP over your present methods of filtration Cost AssuranceCost Assurance

QUESTIONS ? ? ?