Presentation is loading. Please wait.

Presentation is loading. Please wait.

RAINMAKER and RAINMAKER Enviro

Similar presentations


Presentation on theme: "RAINMAKER and RAINMAKER Enviro"— Presentation transcript:

1 RAINMAKER and RAINMAKER Enviro
Spot Free Water Systems RAINMAKER and RAINMAKER Enviro

2 What is R/O? Reverse Osmosis
Water that has had the dissolved solids removed (TDS) Super pure H2O Water that dries spot free Same as many bottled drinking water

3 What is it for Chemical Applications Final Rinse Applications
Improved customer satisfaction

4 How is it used? Spot Free water is generated and stored in holding tanks in the equipment room Automatically Machines are plumbed to use R/O when needed Pre-soak Wax Clear Coat Tri-Foam Spot Free Rinse

5 How does it work? Water is pumped under pressure through R/O membranes
Some of the water passed through the filters and on to the storage tanks Some of the water does not go through the filters and is sent to the next filter or down the drain Each filter in the RYKO R/O systems will produce about 1.5 gallons of pure R/O water per minute

6 What are the Benefits Improved chemical effectiveness
Improved chemical efficiency Improved chemical constancy No spotting drying Higher revenues and profitability

7 When is R/O needed? Anytime the TDS reading is more than 100
Anytime improved wash quality is desired Anytime for up sell to consumers On nearly every touch free wash

8 What is the difference between the RAINMAKER and the Enviro?
The Enviro does not need a water softener The Enviro uses a special water conditioning bar Performance is the same

9 How Do I Size a Holding Tank?
(Number of gallons of R/O use per wash) x (number of washes per hour) = R/O usage per hour 15 x 20 = 300 gallons per hour usage (# Membranes) x (1.5 gallons) x 60 = R/O production per hour 3 x 1.5 x 60 = 270 gallons per hour production ((R/O Usage per hour - R/O production per hour) x Number of hours continuous use = Holding tank min size (300 – 270) x 8 = 240 gallon holding tank

10 What does it mean….. Competitors say 3000 GPD system?
3000/24/60= 2.08 gallons per minute Talk about efficiency… One membrane is about 50% efficient Each additional membrane plumbed in series is also about 50% efficient

11 What kind of maintenance is required?
Periodically membranes need to be cleaned Periodically membranes wear out and need to be replaced

12 RAINMAKER and Enviro Good for chemical applications
Good for spot free drying Good for better customer satisfaction Good for profitability Good for you to sell

13 RAINMAKER and RAINMAKER Enviro