Engineered Products Make-Up Air for Heating and Cooling.

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Packaged HVAC Equipment
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
The Care and Feeding of Silane Art Garcia FM Global March 23, 2006.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Fan Coil Unit Product Line-up. FCU Home Application Show.
Commercial Mechanical Requirements
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
Welcome. TF Commercial Units Sizes from 150 to 400 MBH Propeller Units Power Vented, Direct Spark Ignition Standard Approved for Commercial & Industrial.
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
Model “GT” Size Model “GT” Size
Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters ­Maximum Boiler Design Pressure  All Models – 160 Psig ­Maximum.
Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.
Air-Conditioning Control Systems
Engineered Products Make-Up Air for Heating and Cooling.
Model “BTU” Model “BRT”  20 Gauge aluminized steel tubes  Single orifice (Model “BRT”) or multiple orifice (Model “BTU”) inshot burner  Tubes expanded.
Engineer Presentation
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
 Available with Inputs from 40 to 200 MBH and System Lengths of 10 to 80 Feet  All Units are Field Assembled and Utilize Sterling’s Integral Tube/Reflector.
Reflow System to Electronics Assembly
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015.
Hydrotherm’s NEW KN Series
VENTING AND COMBUSTION AIR
STEAM HEATING.
Product From The Sterling Sales Meeting Presentation On March 23, 2011.
» Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners, and Flue Collector.
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
Engineer Presentation. Efficiency - GAS Clamshell Heat Exchanger 80% Efficient.
Important variables Water: Air: Conversion:
ERMS- Energy Recovery Module. The module uses an Air Exchange ERC energy recovery wheel to recovery waste heat/cooling from the exhaust air stream and.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Air Handler Terminology
Air Handler Terminology
Packaged Rooftop Air Conditioning Unit Presents the.
Maintain IAQ with Energy Recovery Ventilators (ERVs) A ENTERPRISE Visit us at INTRODUCTION TO ERV.
Engineer Presentation. Efficiency - GAS Clamshell Heat Exchanger 80% Efficient.
Aztec Sensible Cooling System  Series ASC 1A01  Indirect Cooler –No direct contact of water into the supply air –Stainless steel cooling tower –Fill.
Section 3 Using Heat.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
HEATING AND COOLING SYSTEMS
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
ClearFire-LC Hydronic Boiler Solution. ClearFire Family Capacities from 400 to 12,000 MBH 2 ClearFire-H - Steam ClearFire-C - Condensing ClearFire-V -
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
What makes up a Unico System
Sigma Rotary Screw Compressors
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Maria’s Restaurant Chapter 2 Section 6
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Unit 7 Gas Heat: Natural and LP
Maria’s Restaurant Chapter 1 Section 4
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
BUILDING HEATING AND COOLING
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
K Series Packaged Units & Commercial Split Systems- 2011
Munters DOAS, Chilled Beams and VRV
Engineering Presentation
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
FBE03: Building Construction & Science
Dunham Bush Air Cooled Package
Presentation transcript:

Engineered Products Make-Up Air for Heating and Cooling

MAKE-UP AIR Why do we need make up air?

EXHAUST AIR KITCHEN HOODS MANUFACTURING APPLICATIONS – PAINT BOOTHS – PROCESS AIR

BUILDING PRESSURIZATION CORRIDOR PRESSURIZATION – FIRE CONTROL – KEEPS ODORS IN APARTMENTS, ETC. BUILDING PRESSURIZATION – REDUCES OUTSIDE AIR INFILTRATION

BUILDING VENTILATION – CONSTANT VOLUME – INTERMITTENT VOLUME

Key Audience Many Restaurants, Apartment Complexes and Factory Upgrades are done through Design Build Projects – Owner and installing contract size the equipment themselves without the use of an engineer Schools, Government Buildings, Concert Halls and New Factories are done through Plan & Spec Projects – Engineers are typically used to layout equipment sizes

HOW CAN TRANE HELP?? Trane Offers a Complete Line of Outdoor and Indoor HVAC Equipment to Satisfy Your Make-Up Air Needs.

Outdoor Units Unit Types Model “GR” Option “G”– Gravity Vented Outdoor Model “GR” Option “P”– Power Vented Outdoor

Indoor Units Unit Types Model “GG” – Power Vented Indoor

Indoor Units Unit Types Model “GX” – Separated Combustion Indoor

Indoor/Outdoor Units Unit Types Model “AH” Air Handler

Arrangements Consists of Individual Pre-Engineered Modules Arranged to Address Your Individual Applications

Furnace Construction Material Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector Duct Furnace Heat Exchangers are Available in 3 Types of Steel Aluminized Steel 409 Stainless Steel 321 Stainless Steel

GAS CONTROL A Full Range of Gas Controls, Including: Single Stage Two Stage Electronic Modulation – Room Sensing – Duct Sensing (W/, W/O Rm. O/R) – Others, Including 4-20 mA & 0-10 VDC Controls and Multi-Furnace Staging

Coil Options Factory Installed Coils – Direct Expansion (DX) – Chilled Water – Steam – Hot water Draw Through Design Maximizes Coil Efficiencies Full Size ASHRAE 62 Compliant Drain Pan 4 Row & 6 Row, Single or Dual Circuit Cooling Coil 1,000-6,300 CFM Range* 3-30 Tons, But There is Flexibility. When in Doubt, Call!

Indoor/Outdoor Units Unit Types Evaporative Cooler Section

ETL Certified 18 Gauge Cabinets Painted Trane Grey 20 Gauge Aluminized Steel Heat Exchangers Single Stage Redundant Gas Valve Low internal static pressures allow for smaller motor break horse power requirements Features and Benefits

Standard Left Hand Access, Right Hand Optional Multiple Gas and Air Control Options 1” Matte Face Insulation

Features and Benefits Ship Loose Parts List

Features and Benefits

Motor Types Open Drip Proof (ODP) Premium Efficiency (PEODP) Totally Enclosed (TE) Premium Efficiency (PETE)

Air Inlet Configuration Indicates – Use of Outside and / or Return Air – Use of an Air Hood (Shipped Separately)

Factory Installed Options Low Leak Damper 409 SS Furnace Drip Pan High Altitude Derate Input Derate Evaporative Cooler – 12” CELdek® Media – 8” & 12“ GLASdek ® Media Clogged Filter Switch Manual Blower Switch Firestat (Supply and / or Return) Freezestat (Time Delayed) Ambient Lockout Interlock Relays (Specify Purpose) Moisture Eliminators Horizontal Return Status Lamps Double Wall Construction Service Convenience Package High / Low Gas Pressure Switch Filters (TA, WA & Pleated) Through the Base Utility Penetrations

Field Installed Accessories High Pressure Regulators Time Clocks GFI Convenience Outlet Thermostats DuctStats Disconnect Switches Evaporative Cooler – Fill & Drain Kit – Freezestat Remote Control Panel

Competitive Product Modine Make Up Air DFP/DBP/DCP – Indoor Unit DFS/DBS – Indoor Separated Combustion Unit – DCS w/ Cooling WeatherHawk Series – HFG, HFP, HBG, HDG, HPG

Competitive Product Modine Make Up Air All Model Types 75 MBH and Go to 1,200 MBH – HFG/P CFM Range 550 – 14,800 Temperature Rise – 20 – 120 F. 80% Thermal Efficiency Maximum External Static Pressure 3” W.C. Available w/ DX or Chilled Water Options – CFM Range 762 – 5,200 – Available on Sizes

Competitive Product Modine Make Up Air ETL Certified On Entire Unit 18 Gauge Aluminized Blower Cabinet 20 Gauge Clamshell Heat Exchanger – 409 SS Optional Double Wall Construction on Blower and/or Cooling Cabinet (Option) Full Range of Air & Gas Controls Available – Equal to Trane Offering Baked-on Polyester Powder Paint

Competitive Product Reznor Make-Up Air RPB(L)/RDH Outdoor Power Vented M/U Air Unit – Gravity Vented Unit (RGB) No Longer Available RPB(L)/HRP/RPV/HRPV PDH/PGBL – Indoor M/U Air SDH/SSCBL – Indoor Separated Combustion M/U Air “L” = Long (400 – 1200 MBH)

Competitive Product Reznor Make-Up Air Size Ranges From 75 MBH – 1200 MBH CFM Range ,000 Outdoor Units CFM Range 560 – 139,000 Indoor Units Temperature Rise F. 80% Thermal Efficient – “PreevA” Products (PDH & SDH) Minimum 81% All Products Power Vented as Standard

Competitive Product Reznor Make-Up Air ETL Certified On Entire Unit Aluminized Heat Exchangers as Standard – 409 S/S Available – Heat Exchangers, Burners, Drip Pan – 316 S/S Available Heat Exchanger Only Double wall Pre-coat RAL 9001 white paint finish Wide Range of Control Options – Mechanical Modulation Available – Electronic Modulation Available Down to 20%-100% Turndown

What Next? These are the project we are working on in the immediate future. – We have many more projects planned for when these are completed.

Variable Frequency Drive SM Vector Line NEMA 1 Enclosures Plenum Rated Operating Range 14 o F Minimum 130 o F Maximum Two Year Warranty

Seismic and Vibration Isolation Curbs

Energy Recovery Module

X1 – 90 + % Efficient Rooftop Unit