Presentation is loading. Please wait.

Presentation is loading. Please wait.

Maintain IAQ with Energy Recovery Ventilators (ERVs) A ENTERPRISE Visit us at INTRODUCTION TO ERV.

Similar presentations


Presentation on theme: "Maintain IAQ with Energy Recovery Ventilators (ERVs) A ENTERPRISE Visit us at INTRODUCTION TO ERV."— Presentation transcript:

1 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my INTRODUCTION TO ERV

2 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my WHAT IS AN ERV? An energy recovery ventilator (ERV) is a type of mechanical equipment that features a heat exchanger combined with a ventilation system for providing controlled ventilation into a building.

3 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my HOW DOES AN ERV WORK? An ERV, exchanges the contaminated room air with fresh outdoor air, in the process recovering more than 65% of the energy from the exhaust air stream. The energy recovery wheel slowly rotates (@ 20 RPM) between the two counter flowing exhaust and supply air streams pickings up the sensible and latent heat from the cooler air stream and transferring to the warmer air stream or vice versa depending on the conditions. The energy recovery ventilator consists of two blowers and a energy recovery wheel. The two blowers run continuously to exhaust the room air and replace it with an equal amount of fresh outdoor air.

4 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my ADVANTAGES OF ERV Helps Designers, Contractors and Building Owners and Operators to Meet IAQ Standard ASHRAE 62.1.2001 and Conserve Energy Enable ASHRAE 62.1.2001 specified Ventilation rates with out Increasing Air conditioning Tonnage Reduces the CAPITAL AND OPERATING COST of Air- conditioning Equipment Ideal for New Construction or Retrofit Applications Meets Space Limitation Requirements/ (Could be Installed in the False Ceiling Area)

5 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my ERV- PRODUCT REVIEW

6 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my BASIC COMPONENTS OF AN ERV Ecofresh Enthalpy Rotor (Molecular Sieve Coated), sealed with Feather Touch Brush Seals to Minimize Cross Contamination and Ensure Long Life, for recovering both Sensible and Latent Energy Exhaust and Supply blowers for ERV 850, 1200 & 1700 (Radial Flow fans for ERV 250 & 500) Synthetic Pre-filters for Removing Particulate Contaminants CNC Manufactured 18G / 20G Powder Coated Cabinet with 16G / 12G Frames.

7 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my Incorporate Enthalpy Wheels

8 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my TECHNICAL SPECIFICATION & SYSTEM FLOW DIAGRAMS ERV 250 / 500 * Measured At 3 Mtrs. Distance (At 90 Degrees), When Unit Is Ducted.

9 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my TECHNICAL SPECIFICATION & SYSTEM FLOW DIAGRAMS ERV 850 * Measured At 3 Mtrs. Distance (At 90 Degrees), When Unit Is Ducted.

10 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my TECHNICAL SPECIFICATION & SYSTEM FLOW DIAGRAMS ERV 1200 / 1700 * Measured At 3 Mtrs. Distance (At 90 Degrees), When Unit Is Ducted.

11 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my TECHNICAL DETAILS FEATURES CNC Manufactured 20 / 18 gauge powder coated cabinet with 16 / 12 gauge frame. World Class Finishing - Siemens grey / off white leather finish. Molecular Sieve coated aluminium, “Ecofresh” Total Energy Recovery Wheel. Compact backward curved radial fans / forward curved dual inlet blowers with external rotor motor. Casing insulated with 19mm closed cells, high density insulation to prevent condensation of moisture on exteriors or interiors of the unit. Large panel opening for easy access to filters, & inspection of other components. Remote start /stop with 1.25 mtr. Long cable. Metallic collars for duct connections. Removable, washable synthetic pre filters. Factor set inbuilt purge. Feather touch brush seals minimize cross contamination & ensure long life.

12 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my APPLICATIONS Health Care–Nursing Homes, Hospitals, Clinics, Specialty Centers, Clinical Labs. etc. Entertainment–Cinema Halls, Multiplexes, Discotheques etc. Hospitality – Hotels, Restaurants, Pubs, Banquet Halls, Fast - Food centers etc. Commercial – Offices, Banks, IT complexes, Conference Halls etc. Places of assembly –Schools, Temples, Educational Instt., Supermarkets, Showrooms etc. Miscellaneous–Beauty Parlours, Gymnasiums etc.

13 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my ASHRAE STANDARD VENTILATION RATES

14 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my Installation Options – ERV 250 / 500 / 850

15 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my Installation Options – ERV 250 / 500 / 850

16 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my Installation Options – ERV 250 / 500 / 850

17 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my Installation Options – ERV 250 / 500 / 850

18 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my INSTALLATION OPTIONS – ERV 1200 /1700

19 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my INSTALLATION OPTIONS – ERV 1200 /1700

20 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my INSTALLATION OPTIONS – ERV 1200 /1700

21 Maintain IAQ with Energy Recovery Ventilators (ERVs) More @ www.drirotors.com A ENTERPRISE Visit us at www.bryair.com.my INSTALLATION OPTIONS – ERV 1200 /1700


Download ppt "Maintain IAQ with Energy Recovery Ventilators (ERVs) A ENTERPRISE Visit us at INTRODUCTION TO ERV."

Similar presentations


Ads by Google