Fan Coil Unit Product Line-up. FCU Home Application Show.

Similar presentations


Presentation on theme: "Fan Coil Unit Product Line-up. FCU Home Application Show."— Presentation transcript:

1 Fan Coil Unit Product Line-up

2 FCU Home Application Show

3 How to Read the Model No.? I F -- Function control R Remote control RA Remote control with heater E with electric heater Nominal Air Volume (CFM) H High Static Pressure __ Normal Static Pressure Type Codes C4 Cassette 4 WayC1 Cassette 1 Way CC Cassette Compact H1 Duct TypeH2 2 nd Generation Duct Type H3 Duct Type High Static F1 Floor Open Side IntakeF2 Floor Open Bottom Intake F3 Floor Concealed MW Mid-Wall Type Chilled Water fan Coil Unit

4 All Series (Present Product) 4 way Cassette Compact 4 way cassette Series Model IFC4-xxHRN4 Model Air Volume (CFM) Series Air Volume (CFM) 600~1500 IFCC-xxHRN4300~500 One 1 Cassette IFC1-xxxHRN4 300~600 Floor Standing IFC1-xxHRN4 IFC2-xxHRN4 150~1000 Floor Standing IFC3-xxHRN4 150~1000 Duct 2-rows IFH2-XHRN4 IFH2H-xHRN4 200~1400 Duct 4-rows IFH1-xxHRN4 IFH1-xHNR4 300~2000

5 All Series (New Products) New 4 way Cassette New Compact 4 way cassette Series Model IFC4-xxxR/RA With Auxiliary Electrical Heater Model Air Volume (CFM) Series Air Volume (CFM) 600~1500 IFCC-xxxR/RA With AEH 300~500 New 1 way Cassette IFC1-xxxR/RA With AEH 300~400 Wall mounted Duct 2-rows IFH2-xxxE IFH2H-xxxE With AEH & Plenums 200~1400 High Static Pressure IFH3H IFH3H-xxxE With AEH 800~2200 Duct 4-rows IFH1-xxxE With AEH & Plenum 250~600 300~2000 200~1200 Mass production on June 1 st, 2008 Duct New 3-rows IFMW

6 Duct Type 2-Rows IFH2 Series Air volume: 200-1400 CFM Air return plenums and air filter are optional IFH2 static pressure is 12Pa IFH2H static pressure is 30Pa, and 50Pa can be customized. be customized. 2-Rows IFH2-XXXE Series (With Auxiliary Electrical Heater) Air volume: 200-1400 CFM Air return plenums and air filter are standard IFH2-xxxE static pressure is 12Pa IFH2H-xxxE static pressure is 30Pa, and 50Pa can be customized.

7 Duct Type New 3-Rows Air volume: 200-1200 CFM Air return plenums and air filter are optional The working static pressure of standard series is 12 Pa, and which of high static series is 30Pa. Also 50Pa can be customized.

8 Duct Type 4-Rows IFH1 Series Air volume: 300-2000 CFM Air return plenums and air filter are optional static pressure is 12Pa 4-Rows IFH1-XXXE Series (With Auxiliary Electrical Heater) Air volume: 300-2000 CFM Air return plenums and air filter are standard static pressure is 12Pa

9 Duct Type  Elegance and prestige----Concealed installation makes the conditioned space more concordant.  Low thickness for easy installation and maintenance.  Low noise fan direct driven by 1 phase and 4 speed setting motor, so there are more choices for variable applications.  The plenum and the air filter are standard, so it is very easy to install.  The auxiliary electrical heater and the new electronics thermostat are standard. And the heater can be controlled independently. Features

10 Duct Type L 490 240 (mm) Connection from right side Note: 1.Only 1400CFM type is 3 rows; 2.Pipe connection way can be selected from left or right. 3.IFH2 Pressure is 12 Pa 4.IFH2H pressure is 30 pa, and 50Pa can be customized. LCFMdB (A) 77020039 82730041 93740043 1140 50048 60048 80051 1546100051 1835 120053 140055

11 ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH2(H)-200(E)2002003 W3210 W43 W12(30) Pa500W IFH2(H)-300(E)3002710 W4310 W59 W12(30) Pa650W IFH2(H)-400(E)4003605 W5410 W72 W12(30) Pa1000W IFH2(H)-500(E)5004500 W6800 W84 W12(30) Pa1000W IFH2(H)-600(E)6005410 W8100 W105 W12(30) Pa1500W IFH2(H)-800(E)8007195 W11000 W150 W12(30) Pa2000W IFH2(H)-1000(E)10009000 W13500 W172 W12(30) Pa2000W IFH2(H)-1200(E)120011000 W16500 W210 W12(30) Pa3000W IFH2(H)-1400(E)140013000 W19500 W250 W12(30) Pa3000W Specifications Duct Type

12 L 490 (590) 240 (340) (mm) Note: 1.Pipe connection way can be selected from left or right. 2.Pressure is 12 Pa 3.Available for 50Hz & 60 Hz LCFMdB (A) 87430041.2 1185 40040.0 45039.4 50043.2 60046.2 1369 75046.2 85046.7 95051.6 1369×340×49 0 120051.6 1369×340×59 0 150051.4 200058.4

13 ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH1-3003002700 W3510 W43 W12 Pa600W IFH1-4004003600 W4680 W44 W12 Pa1500W IFH1-4504504050 W5260 W55 W12 Pa1500W IFH1-5005004500 W5850 W60 W12 Pa1500W IFH1-6006005400 W7020 W105 W12 Pa1500W IFH1-7507506800 W8840 W119 W12 Pa2000W IFH1-8508507600 W9880 W124 W12 Pa2000W IFH1-9509508400 W10900 W162 W12 Pa2000W IFH1-1200120010800 W14000 W175 W12 Pa2400W IFH1-1500150013500 W17550 W236 W12 Pa2400W IFH1-2000200018000 W23400 W360 W12 Pa3000W Specifications Duct Type

14 Optional Accessories  Air return plenums, electrical heaters, 3-way valves, thermostat. For the units without Electrical Heater

15 Duct Type Optional Accessories  New electronic thermostat especially for the units with electrical heater. For the units with Electrical Heater

16 Duct Type Typical Installation 1 Installation

17 Duct Type Typical Installation 2 Installation

18 Duct Type Installation Typical installation sketch (With 2-way valve)

19 Duct Type Installation Typical installation sketch (With 3-way valve)

20 High Static Pressure Duct Type 800, 1000, 1200, 1400 1600, 2000, 2200 IFH3H Series Air volume: 800-2200 CFM Air return plenums and air filter are included For 800 to 1400 CFM unit, the working static pressure is 70Pa For 1600 to 2200 CFM units, the working static pressure is 100Pa

21 High Static Pressure Duct Type IFH3H-xxxE Series Air volume: 800-2200 CFM Air return plenums and air filter included as well as Auxiliary Electrical Heater For 800 to 1400 CFM unit, the working static pressure is 70Pa For 1600 to 2200 CFM units, the working static pressure is 100Pa 800, 1000, 1200, 1400 1600, 2000, 2200

22 High Static Pressure Duct Type Features High air volume, high static pressure, high capacity Easy to clean or change the air filter Extra drain pan to protecting your ceiling Includes air plenum, air filters.

23 High Static Pressure Duct Type ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH3H-8005275 W5860 W350 W70 Pa3000W IFH3H-10007030 W7910 W350 W70 Pa3000W IFH3H-12008790 W9670 W350 W100 Pa3000W IFH3H-140010550 W 350 W100 Pa3000W IFH3H-160012310 W13480 W650 W100 Pa10 kW IFH3H-200014070 W15530 W1020 W100 Pa10 kW IFH3H-220017585 W19340 W1140 W100 Pa10 kW Specifications

24 New Cassette Type Body Dimensions (mm) : 850×235×400 Panel Dimensions (mm) : 1050×18×470 CFM Cooling Capacity dB (A) Electrical Heater 300 3040 W 41.81000 W 400 3790 W 43.71000 W IFCC-xxxR/RA Series R means normal models RA means the models with auxiliary electrical heater

25 New Cassette Type Dimension (mm): 580×254×580 Panel Dimension (mm): 650×30×650 Dimension (mm): 840×240×840 840×310×840 Panel Dimension (mm): 950×40×950 Compact type IFCC-xxxR/RA Common type IFC4-xxxR/RA CFM Cooling Capacity dB (A) Electrical Heater 300 3000 W 38.81000 W 400 3780 W 40.11000 W 450 4050 W 40.8/ 5005480 W42.5/ CFM Cooling Capacity dB (A) Electrical Heater 600 5720W 44.62100 W 750 6990W 45.12100 W 850 7270 W 45.82700 W 9508220W47.72700 W 120010390 W49.52700 W 150012870 W51.82700 W

26 New Cassette Type  Built-in body design, integrative design with the ceiling, makes the installation room more concordant;  Built-in high head drain pump can lift the condensate water up to 500 mm and drain out smoothly;  New designed coils makes the water pressure drop decrease and makes the capacity higher;  4-speed motor gives you more choices.  Brand new appearance of common 4-way cassette. Features

27 Floor-standing Type Dimension (mm): 550×212×545 750×212×545 950×212×545 1250×212×545 Concealed type IFF3 Dimension (mm): 880×225×626 1000×225×626 1200×225×626 1500×225×626 Exposed type IFF1 air return from side IFF2 air return from bottom CFM Cooling Capacity Heating Capacity dB (A) 150 1150 W2540 W 32 250 1870 W4170 W 35 300 2530 W5640 W 37 400 3270 W7220 W 39 450 3970 W8850 W 41 500 4850 W10280 W 43 600 5640 W12240 W 44 800 6520 W15350 W 46 900 7850 W18200 W 48

28 Floor-standing Type Available now! New grill Exposed type IFF4 IFF5 Special design

29 Floor-standing Type Features  All metal parts are made of commercial grade galvanized steel, providing maximum protection against corrosion.  Soft, streamlined appearance.  Air filter is easily removed and cleaned.  Low noise fan direct driven by single phase and 3 speed setting motor  If cooperate with the newly designed thermostat- KJR-15B/E(P), when the inlet water temperature is higher than 20 ℃ in cooling mode or lower than 35 ℃ in heating mode, the fan will be shut down automatically to maintain the comfort.

30 Floor-standing Type Features  Thermostat and 3-way valve are optional

31 Wall-mounted Type  Air volume range: 250, 300, 400, 500 and 600 CFM.  The appearance is the same as wall mounted indoor unit for MDV NEW IFMW Series!