Universal Interrupted Electronic Oil Primary R7184U Training Module

Slides:



Advertisements
Similar presentations
… for Combustible Gas Detection S4000C Intelligent Sensors..
Advertisements

Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
Motorcycle product sheets
Heating Control Devices
R7284U1004 Universal Digital Electronic Oil Primary Training Module
S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)
Furnace Troubleshooting
Protecting life, environment and property… 1 AutroFlame Detectors ID: AFLAME_X33_1_intro
S8910U1000 Universal Electronic Ignition Modules Training Module
Engineer Presentation
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Product Introduction.
ST9120U1003 Universal Electronic Fan Timer Training Module
S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module
AccuMax Multi-Point Injection Mechanics
TR20 Series Wireless Training Slides New Product Introduction March 2009.
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
TrueZONE™Panels Training Module
Variable Speed Indoor Blower Motor Robert Helt Technical Conference - Panama City Beach, Fl
WSK-24 Wireless Occupancy Solution New Product Introduction Customer Sales Presentation June 2009.
Service/Review... Rule # 1: Use the KISS Principle!
BFP 21 L3 Oil Pump.
RESIDENTIAL AIR HANDLERS
HYDRONIC HEATING AQUASTATS
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
Q3X ■ Solves challenging contrast part-detection applications ■ Fast as 250 µs response speed able to capture up to 2,000 events per seconds ■ Angled three-digit.
CONTROL BOX RMG
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
BUrners TRAining CEntre CONTROL BOX RMO BUrners TRAining CEntre PRESS SERIES ONE STAGE TWO STAGE THREE STAGE Dedicated to: RL SERIES ONE STAGE TWO.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
Service Section Technical Training December 2005.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
LCD Wiring Diagram Presentation B / B.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
E3 HVACR Controls and Devices
shift to the Test Mode (Forced Operation).
Duct Free System.
New Electric Actuators EA Type
Quick Start Guide for Flex Flow Pump
Unit 13 Oil-Burning Equipment
Service is the Key Ron Rayburn – Director System Controls.
Introducing the Bradford White ICON System™ and Accessory Packages
© 2004 Refrigeration Training Services - Refrigeration Categories v1.1
Advisor Advanced Release FW120.
E3 HVACR Controls and Devices
7. Test operation.
Asahi/America Electric Actuators Series 94.
Heat-Timer Control Options
Roof Top Unit Overview (MAGNUM)
Module 5: Wiring and Controls
CONTROL BOX RMG
CONTROL BOX RMO
Flotection: Building Main Shutoff System
Asahi/America Electric Actuators Series 94.
CONTROL BOX RMO
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
S8910U1000 Universal Electronic Ignition Modules Training Module
ST9120U1003 Universal Electronic Fan Timer Training Module
VR8345 Universal Electronic Ignition Gas Valve Training Module
System 57 Gas Control System
TR20 Series Wireless Training Slides
Fluid Power System Electrical Control
Presentation transcript:

Universal Interrupted Electronic Oil Primary R7184U Training Module

What you will learn R7184U Product Overview Key Features and Benefits Installation and Set Up Troubleshooting Product Cross Reference R7184U Oil Primary Advantages

R7184U Interrupted Electronic Oil Primary What is the R7184U? It is a line voltage, safety rated, primary control for residential oil fired burners used in boilers, forced air furnaces and water heaters. Applicable for use with both hydronic and forced air systems. Used with a cad cell flame sensor, operates an oil burner and optional oil valve. Universal Oil Primary Part Numbers: R7184U1004 R7184U1012 R7184U1020

R7184U Key Features Universal compatibility This control replaces Carlin, White Rodgers and all prior Honeywell Oil Primary Controls EnviraCOMTM communications enabled: Includes EnviraCOM™ Connection for local networking & diagnostics Compatible with the Honeywell EnviraLINK™ remote monitoring application, which enables dealers to monitor their customers systems remotely.

R7184U Key Features Diagnostic LED Indicator light monitors burner flame status and system lockout The versatile R7184U includes these “Exclusive Features”: Pump priming cycle Cad cell flame strength indicator Limited recycle Extended Service Life (Control and Application)

Additional R7184U Features Available in 15-, 30-, and 45-second lockout times R7184U1004 = 15 second lockout R7184U1012 = 30 second lockout R7184U1020 = 45 second lockout Optional valve-on delay, blower-off delay models: Models: 15 seconds, or selectable 0 or 15 second valve-on delay Zero time or selectable 0-, 2-, 4-, 6-minute blower-off delay Safe start check – check for flame presence prior to lighting the burner Compatible with power venters without integral timers Oil-resistant plastic cover for electronics

R7184U Feature Function Benefit Pump Purge Temporary setting of safety timing to 4 minutes Allows installer to purge oil lines without remaining at oil primary CAD Cell Resistance Readout Flash CAD resistance range while burner is running Allows installer to check that flame strength is adequate prior to leaving job site Limited Recycle Limits recycle to 3 per any one call for heat Detects running saturation or poor combustion from partially clogged nozzle and locks out to prevent heat exchanger clogging or oil flooding Limited Reset Limits resets to 3 during any single call for heat Prevents homeowner from continually pressing reset button when service is needed Communications HVAC communications Allows local and remote diagnostics for better troubleshooting and new services

R7184U Feature Function Benefit Communicating Accessories Additional devices to utilize communications capability Remote access, test tools Leadwire and Quick Connect Termination Support both quick connects and leadwire termination Replaces both OEM and installed base with one model Alarm Contacts Indication of control lockout Allows connection to security system or other indications to warn of control lockout Selectable Valve On Delays Field selectable valve on delay Allows user to inventory and carry one universal product for various valve on delay times Selectable Blower Off Delay Field selectable blower off delay Allows user to inventory and carry one universal product for various blower delay on times

Key Features: Oil Primary R7184U EnviraCOM™ Communications Data Port Diagnostic LED – enables monitoring of system status to speed troubleshooting Limited reset – prevents continued homeowner reset without proper service checkout EnviraCOM™ Terminals. Alarm Contacts (dry contacts, normally open) – Provides switch action to remote alarm panels T-T Terminals Timer Setting Dip Switches – Universal Application

Installation

Installing the R7184U Follow the installation instructions per the application: Locate proper location Mount Wire per application type Oil fired boiler without EnviraCOMTM Oil fired boiler with EnviraCOMTM Oil fired forced air with EnviraCOMTM Etc.

Set-Up

Set-Up of the R7184U: Setting Delay Times 1st Switch: Valve On Delay 2nd & 3rd Switches: Burner Motor OFF Delay 0 15 Sec Valve On Delay ON Easy access to set up delay times. 1 2 3 ON ON ON ON 1 2 1 2 1 2 1 2 0 min. 2 min. 4 min. 8 min.

Setting Delay Times Oil Pump Delay ON 1 2 3 OR Delay Off Delay On ON 1 2 3 ON ON OR 3 3 Delay Off Delay On

Model Valve ON Delay Blower OFF R7184A None None R7184B 15 None Setting Delay Times Delay Choices Model Valve ON Delay Blower OFF (Seconds) (Minutes) R7184A None None R7184B 15 None R7184P 15 0-2-4-8 R7184U 0 or 15 0-2-4-6

Troubleshooting

Troubleshooting of the R7184U The indicator light on the control provides lockout, recycle and cad cell indications as follows: Flashing at 1 Hz (1/2 second on, 1/2 second off): system is locked out or in restricted mode. Flashing at 1/4 Hz (2 seconds on, 2 seconds off): control is in recycle mode. On: cad cell is sensing flame. Off: cad cell is not sensing flame. Cad Cell Resistance Check For proper operation it is important that the cad cell resistance is below 1600 ohms. During a normal call for heat, once the control has entered the Run mode, press and release the reset button. Indicator light will flash 1 to 4 flashes. See next slide for equivalent cad cell resistance.

Troubleshooting: Diagnostics Push lockout button once to get cad cell resistance and system status Flashes Indication Steady Control is sensing flame Off Control is not sensing flame Flashing ( ½ sec on / ½ sec off) Control is in lockout or restricted mode Flashing ( 2 sec on / 2 Sec off) Control is in recycle mode 1 < 400 ohms 2 400 - 800 ohms 3 800 - 1600 ohms 4 1600 – 5000 ohms *CAD Cell Ohms decreases with increased flame brightness

Troubleshooting of the R7184U For Honeywell EnviraCOM™ enabled equipment Read EnviraCOM Error Codes Line Voltage Cad Cell Ohms The QuickLookTM 72 is available through www.onwatchinc.com

Product Cross Reference

Product Cross Reference Where do I find Honeywell universal electronic oil primary cross reference information? www.customer.honeywell.com Honeywell Application Selection and Cross Reference Guide – Form 63-9575 Honeywell Laminated Truck Visor – Form 63-9581 Honeywell Oil Primary Countermat – Form 63-9661 Honeywell Residential Technical Support: 1-800-468-1502

Oil Primary Cross Reference Table This chart can be found in the Residential Combustion Application Guide: Form #63-9575

www.customer.honeywell.com See Cross Reference Search box in right column.

R7184U Oil Primary Advantages When promoting the R7184U Universal Oil Primary keep these advantages in mind: Universal Compatibility This control replaces Carlin, White Rodgers and all prior Honeywell Oil Primary Controls Honeywell R7184U “Exclusive Features” Pump priming cycle Cad cell flame strength indicator Limited recycle Diagnostic LED Indicator light monitors burner flame status and system lockout EnviraCOM communications enabled It includes EnviraCOM™ Connection for local networking & diagnostics Compatible with Honeywell EnviraLINK™ remote monitoring application

R7184U Interrupted Electronic Oil Primary Knowledge Test

R7184U Oil Primary Knowledge Test Now that you completed this training module, take the short quiz to test your knowledge.

Test The R7184U can be used in both hydronic and forced air systems? T or F The Honeywell R7184U can replace ALL prior Honeywell oil primary controls, as well as Carlin and White Rodgers controls? T or F There is one way to determine cad cell ohms and that is through the diagnostic LED? T of F The R7184U is available in 3 lockout times, 15, 30 and 45 seconds? T or F The pump priming cycle requires that the installer be present at the oil primary to purge the line? T or F

Test Limited reset prevents the homeowner from continually pressing the reset button instead of calling for service? T or F The diagnostic LED can identify system lockout? T or F The valve on and blower off delay times are factory set and cannot be set by the installer during installation? T or F The limited recycle features can help prevent clogging the heat exchanger or flooding? T or F EnviraLink is the remote monitoring service that can be used with R7184U EnviraCOM enabled oil primary? T or F

Answer Key T F