University of Ljubljana, Faculty of Electrical Engineering - Slovenia

Slides:



Advertisements
Similar presentations
SPICE modelling of PFC controller
Advertisements

Mississippi State University Intro to Electrical & Computer Engineering P ower S ystem Application Laboratory (PSAL) September 25, 2003 Schweitzer Engineering.
Powerline Communications: Channel Characterization and Modem Design Yangpo Gao Helsinki University of Technology
Distributed Power Systems ELCT 908
Standardization Aspects in UHV Networks New Delhi, January 2009 Denis Dufournet Chairman IEC TC17 Member CIGRE WG A3-22.
Importance of advanced simulations of electrical system in wind turbines April 2010.
Greenbench: A Benchmark for Observing Power Grid Vulnerability Under Data-Centric Threats Mingkui Wei, Wenye Wang Department of Electrical and Computer.
1 Green River Utah Area Transmission and Distribution System – January 16, 2009.
Luis Layo (SP) Session 4 – Block 3 – Selected Paper - Question 6 Barcelona May Analysis of the effects of wind farms dynamic behaviour on.
Power Plant Construction and QA/QC Section 7.4 – Hydroelectric Generators, Transformers and Controls Engineering Technology Division.
1 Some Issues about Big Data in Power Grid Gary Quan.
Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Controllability of DG helps managing Distribution Grids J. A. Peças Lopes
1 Clemson University Electric Power Research Association Zhenyu Fan IEEE Student Member Dynamic Performance of Distribution Systems with Distributed Generation.
Endesa Colombia Our Distribution System In Front Of The Development Of Colombia.
Diagnostics of photovoltaic power plants operation
Cheng-Ting Hsu, Huang-Shin Cheng Presenter: Cheng-Ting Hsu Transient Stability Study of the Large Synchronous Motors Starting and Operating for the Isolated.
EE 445 Course Presentation Power System Protection
Frankfurt (Germany), 6-9 June 2011 Louise Jakobsen, Danish Energy Association – Denmark – Session 3 – Paper 0811 Louise Jakobsen, Danish Energy Association.
Managing a Power System with 40% Wind Dr Alan Rogers EirGrid.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
ADVANCED SPECTRAL ANALYSIS OF OUT-OF-STEP OPERATION OF SYNCHRONOUS MACHINES Zbigniew Leonowicz BSI Riken, ABSP Lab. Wako-shi, Saitama, Japan
Steady State Analysis Of A Microgrid Connected To A Power System
Alain Schenk, Switzerland, ALPHA 3, Block 3.1, Selected paper Barcelona May ASSESSMENT OF PROTECTION SCHEMES: A KEY FACTOR FOR RELIABILITY.
Cheng-Ting Hsu Presenter: Cheng-Ting Hsu Cogeneration System Design for a High-Tech Science-Based Industrial Park Department of Electrical Engineering.
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
Air Blast Circuit Breaker
Name Of The College & Dept
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Frankfurt (Germany), 6-9 June 2011 Romanens – CH – S3 – 0220 Impact of Distributed Generation on Grid Protection BKW FMB Energie AG Switzerland Florian.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
Circuit Breaker Pictures
Power System Protective Relaying-Part One
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Design a protection System of 220/33kV Grid Station United Arab Emirates University College of Engineering Saif Mohammed AL Aryani Ahmed Soruor.
Announcements Design Project has firm due date of Dec 4
Sub Station.
Protection of Power Systems
Agenda TSOG 8th November
Quality and Security Assessment of Protection Systems
SUB-STATIONS.
Inverter Disconnects During Transmission Disturbances
Power Generation and Distribution
PMU Emulator for Power System Dynamics Simulators
Luka Strezoski Marija Prica
3rd European Conference on Renewable Energy Systems (ECRES 2015)
the CERN Electrical network protection system
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Sahar Rahim MS-Electrical Engineering Supervisor: Dr. Nadeem Javaid
EU-IPA12/CS02 Development of the Renewable Energy Sector
High Voltage Power Circuit Breakers
FAULT ANALYSIS - BALANCED FAULT
Protective Relaying Conference
ELECTRICAL POWER-II Electrical engineering sixth semester
Peter van Oirsouw (Phase to Phase)
Powerline Communications: Channel Characterization and Modem Design
UNIT V STABILITY ANALYSIS 9
Student’s Name with USN No.
Grid integration and stability of 600MW windfarm at Kriegers Flak
Power System Protective Relaying-Part One
The Safe Use of Electricity
Sami Repo Tampere University of Technology FINLAND
LOAD BEHAVIOUR DURING VOLTAGE DIPS
PREVENTIVE WARM-UP OF PHASE AND GROUND WIRES OF OVERHEAD POWER LINES BY LOADED DEVICES IN THE PERIOD OF GLAZE DANGER Y.R. HUNGER (ELSI GROUP), Ju.V. DEMIN,
Review of Distribution Network Protection
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Introduction to Distribution Systems
HIGH VOLTAGE ENGINEERING Presented By P.Sindhu Asst.Prof EEE Dept
Prepared by: Ismael K. Saeed
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

University of Ljubljana, Faculty of Electrical Engineering - Slovenia INFLUENCE OF FAULTS IN DISTRIBUTION NETWORK ON BEHAVIOR OF ASYNCHRONOUS GENERATORS IN SMALL HYDROELECTRIC POWER PLANTS Grega BIZJAK University of Ljubljana, Faculty of Electrical Engineering - Slovenia Thank you mister president. Dear coleags, ladies and gentleman!

Introduction The number of small Hydroelectric power plants (SHPP) in distribution networks in Slovenia increase. Generators in SHPP react to the disturbances in distribution network: increase in speed increase in short circuit power in network Digital simulation is an appropriate tool for the investigation of such problems in networks. In some mountainous regions in Slovenia the production of electrical energy from small hydro-electric power plants covers almost 50% of power demand. A three phase asynchronous machines are normally used as generators. In this networks there are a large number of short circuit faults and line interruptions each year. Each fault represent a disturbance to the generators.

Observed distribution network 20 kV distribution network with overhead lines. More than 50 small hydroelectric power plants with mostly asynchronous generators. Total power generation of 2000 kW or 45% of the load demand. The observed network operates on 20 kV voltage level. In the network there are 50 small hydroelectric power stations, more than 30 of which are normally in operation. Most of them have one or two asynchronous generators. The total average active power generation is around 45% of the load demand.

Dynamic analysis of the network Influence of the faults on the behavior of generators in SHPP Increase in speed of asynchronous generators Influence of the generators on the short-circuit current in a network Influence on currents and voltages in network during the one-phase short-circuit Influence on currents and voltages in network during the three-phase short-circuit With the help of dynamic simulation a different short-circuit faults were simulated in the network and the generators responses were observed. We focused on two main subjects: the increase in speed of generators and the increase in the short circuit power by the generators in the network.

Increase in speed of asynchronous generators The speed of asynchronous generators during the fault increases far beyond their nominal speed. According to results, the most dangerous fault is near the generator. With a normal fault clearing times, faults with a residual voltage of less than 20% will result in a speed twice as fast as synchronous speed.

Simulation of three-phase short-circuit Simulations of short-circuit fault in a network with and without the consideration of generators were also made. The aim was to determine the influence of generators on the amplitude of short-circuit currents in the network. The results show that generators increase the short circuit power in the network for over 25%.

Conclusions During the fault in distribution network, which is not cleared fast enough, the asynchronous generators may reach the twice of nominal speed. Generators have very small influence on conditions in the network except on the tree-phase short-circuit currents. After the results were obtained, the generators’ protection devices were checked, as well as the circuit breaker capacities in the substations. In the period since most of the power plants were put into operation, no serious problems have occurred in the network.