ALARM APPLICATIONS.  DS200 Alarm Interface is an infrastructre, which provides a platform to program DS200 system via one central point or collect the.

Slides:



Advertisements
Similar presentations
Gen RGen SGen T 4p +1 Power socket 40A for Gen POWER ALARM ON OFF ENT/EX High Temp DC pri Alarm DC sec Alarm Rectifier Fail Battery Disch Air/Cond Fail.
Advertisements

PABX with Caller ID MS48C. MS48C is now ready for exports!!! Ergonomic Design in Plastic Cabinet Caller ID Detection SMS Transmission MS48C - PABX with.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
…performance audio networks. ABOUT RockNet => RockNet provides ultra low latency and very high audio quality. Genuine Audio Technology  RockNet is a.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
EMerge Browser Managed Security Platform Module 2 Hardware install.
Presentation by: Serena, Ann & Nicole
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
The physical parts of Computer
Computer Basics 1 Computer Basic 1 includes two lessons:
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
DP Cabinet.
Microprogrammes control the KOMBIS TMM8003. For the reliable operation of its systems and devices there are several programs located in two controllers.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
P07301 Summary Data Acquisition Module. Team Members.
Chapter 8 Output Modules.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
Dr. Hoganson CSIS HC11 Demo Program This is our first lab using the 68HC11 microcontroller. We will “talk” to the microcontroller from a PC, run.
Module 2: Hardware and Terminology
INSTALLATION. PURPOSE To learn the basic steps of installing DS200 systems.
SXBlue II GPS CHAPTER – I ABOUT HARDWARE AND SOFTWARE.
COMPUTER SYSTEM.
Time Division Multiplexing School of Physics and Astronomy Department of Particle Physics Elissavet Papadima 29/5/2014.
Unified-PCMC Ver. 7 TDA100D ver. 5.1 support TDE/NCP ver. 4.2 support
1 © Red Lion Controls Inc. Introducing the RAM 9000.
9000U Quick Guide Marketing & RMA Department XELTEK 8/28/2015.
Computer Insides and Out Computer Basics 1.1. Basic Personal Computer System  A computer system consists of hardware and software components.  Hardware.
DS200 IDEA GENERAL STRUCTURE. PURPOSEPURPOSE The purpose of this presentation is to explain the setup and the use of DS200 IDEA application.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
IP STRUCTURE OF DS200 SYSTEMS
Copyright © 2007 Heathkit Company, Inc. All Rights Reserved PC Fundamentals Presentation 43 – The Network Interface Card (NIC)
Single Loop Analogue addressable fire control Panel
Getting Started With an Unmanaged Switch HUE-500.
Translate the following message:
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
RSG (Remote Service Gateway). 1. Overview  Overview The LDK-RSG (LDK-Remote Services Gateway) is a remote gateway that provides a fully transparent connection.
HIGH CAPACITY PBX SYSTEM - TECHNICAL INTRODUCTION -
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
DS200 IDEA SYSTEM PARAMETERS PURPOSEPURPOSE To explain the details of all system parameters in Idea.
Modem A Presentation Department of Computer Engineering,
Case Study Computer Controlled Radiation Monitoring System
The Guts. CPU CPU Socket The CPU is generally a 2 inch ceramic square with a silicon chip located inside. The chip usually about the size of a thumbnail.
Hardware Training Product: ITMS2.
GS3055-I Installation Process
DS200 IDEA EXTENSION PORT PARAMETERS PURPOSEPURPOSE The purpose of this presentation is to explain the details of all the extension port parameters listed.
Welcome to Product Workshop 2008!. The Indication Group Panel Meters Large Displays Sensors Temperature Controllers Signal Conditioners.
ST26 4 LINE DISPLAY FEATURE PHONE Hazırlayan: Seyide Doğru.
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
Computer Hardware – System Unit
Hardware Introduction – Standard vs Q.i
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
PRESENTATION. Parts of the PCOS (3) Operator LCD Screen with Counter (4) Printer Compartment (5) Transmission Port (9) “RETURN” Button (8) “CAST” Button.
ST30 GRAPHICAL DISPLAY FEATURE PHONE Hazırlayan: Seyide Doğru.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
 Business Systems  Sales Presentation.  Euro ISDN & ISDN Feature Enhancements (CPC-EX V2) Euro ISDN Multiple ISDN pipes Sub-addressing 3.1Khz Audio.
Kirk 500 DECT Config (use with systems that require more than 1 Base) Warden Call CO1 CO2 BT Line Wardens Office Telephone Line Panasonic Line.
A Presentation on DX EPABX a product of Coral Telecom Limited.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
COMPUTER COMPONENTS Ms Jennifer Computer Components.
Modem. Introduction: A modem [Modulator -Demodulator] is a device. Data communication means transmitting digital information form one computer to other.
DS200 EEPROM PROGRAMMING.
Site Controller Unit and Trunk Interface Unit
AC500 High Availability System – CI590 Overview
Computer Hardware – System Unit
HIGH CAPACITY PBX SYSTEM - TECHNICAL INTRODUCTION -
Identifying SLC 500™ System Components
Modem A Presentation Department of Computer Engineering,
GasGard 100 Control System
Presentation transcript:

ALARM APPLICATIONS

 DS200 Alarm Interface is an infrastructre, which provides a platform to program DS200 system via one central point or collect the alarm  Basically, DS200 Alarm Interface consist of a central DS200 system and a PC on which the applications will be run

ALARM APPLICATIONS System Requirements: -DS200 Alarm Card -DS200 Alarm Supply (AL04) -Alarm Panel -Power Supply (220V)

ALARM APPLICATIONS DS200 Alarm Card: –It is a card with 4 channel outputs and 28 channel inputs which is using the serial communication slot of the system instead of the PCM channels –The card has 8 RJ45 connectors directly on board ● The 1st one is used to output some alarm signals to a specific alarm panel. The rest is used to input different alarm signals from 28 different sources (especially for Rural applications)

ALARM APPLICATIONS The four alarm outputs on a PABX system are used for: 1. PABX is fed by the battery 2. PRI connection was broken 3. Redundant CPU is in service 4. A card is powered OFF The outlook of the alarm panel, which is used to visualize these alarm signals

STOPPING ALARM ● This program allows stopping the alarm signal on EX200(Alarm) Alarm Module P Parameters P: 1,2,3,4 The number of the LED on Alarm Module Notes: The alarm on the top LED of the module can be stopped by dialing 1, whereas the alarm on the bottom LED can be stopped by dialing 4.

ALARM APPLICATIONS DS200 Alarm Panel: -It required a feed of 12 VDC. In order to provide the 12 VDC feed, a power module which is called AL04 is available to convert the 48 VDC output of the system to 12 VDC

ALARM APPLICATIONS Cabling: -In order to make the cabling of alarm card through the 8 RJ45 connectors on the card, pieces of CBL-16 MDF Cable is used -The first 4 channels of the alarm card is used to drive an alarm panel fed by a 12 VDC supply -The input of this power module is taken from the battery connector of the system

ALARM APPLICATIONS - There are also four alarm channels to carry the outputs of the alarm card to the alarm panel -The inputs and outputs are carried in parallel The illustration of the cabling of the power module

ALARM APPLICATIONS Application: -After cabling of Alarm Card, Alarm Panel, Battery and Alarm Supply, insert the Alarm Card into a slot of DS system -Make sure that the order of cabling is correct for the connection of the cable mentioned in the Installation guide Please see the pairs in the 2 CBL-16 cables and the corresponding alarm channels that are presented in the Installation guide

ALARM APPLICATIONS DS200 ALARM CARD DS200 ALARM SUPPLY AL04 ALARM PANEL L For battery connection

ALARM TABLE -After all, you can manage alarm signals from IDEA according to the alarm types –This menu offers a facility that can be activated only through IDEA, and it is used to activate alarm on certain functions. This line is used to activate Alarm Panel

ALARM TABLE The following alarm functions can be programmed: ● Extension Fail: The error when an extension has left his telephone off hook. ● PRI Synchronization Error: The error when there is a failure on PRI synchronization. ● Card Error (General): The error when a card has been powered off. ● Card Error (EVM) / Card Error (SS7): Reserved for future use. ● Analog Trunk Error / E&M Trunk Error / E&M PLC Error: The error when the lines are out of service or there is no dial tone on the lines. ● Rural Extension Test Error: The error when there is failure in EX200 (0/16R) tests. ● Main Power Supply Error: The error when there is 220 V mains failure. ● CPU Card Error: The error when the system is working on the redundant CPU

ALARM TABLE The following media can be programmed for showing alarm: ► FT Alarm: The LCD of FT20 connected to the first extension of the system. ► CM Alarm: INFO file that is a sub-file of Net-CM program. ► LOG Alarm: DS200.LOG file of IDEA. ► Alarm Lamp: The Alarm Module of the system. Within this option, the LED on which alarm will be displayed, can also be selected. ► Relay Alarm: The relay(s) on CPUKON card. Within this option, the relay number can also be selected (for DS200 systems). ► KTS Alarm: The LEDs of fast dial keys on FT20 / LT200 (-H) and DSS modules.These LEDs start blinking when the assigned ports are problematic (like dial tone failure, or synchronization lost, etc…)

THANK YOU VERY MUCH...