FIRE SERVICES AT DATA CENTRE

Slides:



Advertisements
Similar presentations
Presentation On INERGEN
Advertisements

Fire Extinguishers 29 CFR Session Objectives You will be able to: Identify different classes of fire Choose the appropriate type of extinguisher.
The role of the Fire Marshall / Fire Warden
A new opportunity from 3M 3M™ Novec™ 1230 Fire Protection Fluid Sustainable technology for special hazards A new opportunity from 3M Today, I.
PORTABLE FIRE EXTINGUISHER TRAINING Section Montana Department of Labor & Industry Occupational Safety and Health Training Institute.
Fire protection systems
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Viking TotalPac2 FireFlex Dual / 1230
Fire Extinguishers: types and uses John Carmichael OH&S and IM.
Fire Prevention.
Stages of Fire Detections and Extinguishants From Ginge-Kerr Danmark A/s & BMTT Corporation S/B (www. ginge-kerr.com)
FIRE SAFETY TRAINING THE LOSS PREVENTION UNIT OF THE OFFICE OF RISK MANAGEMENT.
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
1 Portable Fire Extinguisher Training. 2 Knowledge Assessment 1.What three things must be present to maintain combustion? 2.Name four classes of fire?
2 THEME The important thing from the point of view of fire safety is – how one interprets these properties. Thorough knowledge is essential to understand.
TOOL BOX TALKS Fire Safety. Fire Safety Tips At least one smoke alarm on each level of building Test smoke alarm monthly and replace battery at least.
Copyright © Center for Systems Security and Information Assurance Lesson Seven Physical Security.
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
How to create... A Fire Evacuation Plan.
“Fire Extinguishers”.
2.01 Understand safety procedures
LNG Hazards.
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
BY BILLY NIGZUS TERM FIRE ALARMS. WHAT ARE FIRE ALARMS ? Fire alarms are a device or a system that alert people when there is a fire. A device.
Clean Agent Fire Suppression Alternatives
Fire Suppression Systems Association PRESENTS:
NFPA-12 Edition 2005 What “IMPACT” will the changes to NFPA-12 have on the design and installation of a CO 2 system?
What is fire? Definition: A self-sustaining rapid oxidation of a combustible material giving off heat and light.
Inert Gas Fire Extinguishants
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
If you hear the fire alarm sound, evacuate immediately! Check door for signs of fire Close doors behind you to prevent fire & smoke spread Keep storage.
SINORIXTM CDT Product Presentation.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.

Syrereducerande anlägg – Vad är det ? Erik Secher Kidde Sweden AB.
3M™ Novec 1230™ Fire Protection Fluid
Add name of trust / organisation in box 1 and name of trainer in box 2. Delete THIS box.
Kidde FM-200® Product Review
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
NOVEC Fire Suppression System
2012 Lik Kai Pacific Sense March PACIFIC SENSE Company Intro.
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
Fire Extinguishers 29 CFR © Business & Legal Reports, Inc Session Objectives You will be able to: Identify different classes of fire Choose.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Hot Work Permit Osan AB Fire Emergency Services.
Water Mist Systems Chapter 6. Objectives Evaluate water mist as a potential halon replacement Discuss the applications for water mist systems Compare.
FINETUNETechnologies মানব সেবায় প্রযুক্তি... Cell: , Skype: finetune786,Facebook:
Fire Extinguisher Training
Safety and Prevention of Typical Fire Plan
Fire Extinguisher Training
What you will learn in this session
FIRE PROTECTION & SECURITY in ELI Beamlines
Fire Extinguisher Training
What Library Staff Should Know About Fire Safety
EXTINGUISHER TRAINING Presented by: Dan Klimek Sisk & Company.
“ Highlighting the risks and challenges presented by modern data-center cooling systems in fire detection and suppression applications. “ Dave Boyack Sales.
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
Fire Safety/Extinguisher Use
Fire Extinguisher Training
Emergency Electrical Power Supply for Buildings
Environmental Health & Safety
Fire Safety Training 1.
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
Fire Extinguisher Training
Presented by: Margaret Iregi & Enock Biamah.
Fire Suppression for your IT Solution
Presentation transcript:

FIRE SERVICES AT DATA CENTRE

FM200 TRAINING COURSE

Introduction of FM 200

THE PROPERTIES OF FM-200®

ASHRAE Designation = HFC227ea WHAT IS FM-200® ? C F H ASHRAE Designation = HFC227ea

THE PHYSICS OF FIRE Fire Triangle Fuel, oxygen, heat What is fire? A series of highly exothermic chain-branching free radical reactions Removal of any element of fire triangle results in suppression

Fast & Efficient Performance Removes heat, so fire can’t sustain itself

FM-200® CHEMICAL/PHYSICAL EXTINGUISHING MECHANISM 80% 20% Halon 1301 FM-200®

How is FM-200® Applied? Cup Burner Conc. [Heptane] - 5.8% Use Concentration [Minimum] - 7.5% for ISO compliance Maximum Discharge Time limited to 10 Seconds

FAST & EFFICIENT PERFORMANCE Compact storage space requirements Halon 1301 CO Inert Gas

HUMAN SAFETY FM-200® is completely safe for use in occupied spaces.

FM-200® IS FAST & EFFECTIVE Reaches extinguishing concentration within 10 seconds Provides ACTIVE Fire Protection FM-200® IS FAST & EFFECTIVE

FM-200® ENGINEERED SYSTEMS

ENGINEERED CENTRAL STORAGE FM-200® SYSTEM Distribution Pipe Smoke Detectors Discharge Nozzles Containers Manual Station Raised Floor

PRIMARY APPLICATIONS Computer Rooms

3M™ Novec™ 1230 Fire Protection Fluid Novec 1230 fluid has distinct environmental benefits Ozone depletion potential (ODP) of 0 5 day atmospheric lifetime Global Warming Potential (GWP) of 1 THE NEW CLEAN AGENT

FM200 CONTROL EQUIPMENT

FM200 CONTROL EQUIPMENT Kentec Panel Kentec lock off

FM200 CONTROL EQUIPMENT Kidde Panel Kidde Panel

Viking & Notifier Panel FM200 CONTROL EQUIPMENT Chubb Panel Viking & Notifier Panel

FM200 CONTROL EQUIPMENT Thorn Panel

FM200 CYLINDER

FM200 CYLINDER Kidde FM200

FM200 CYLINDER Chemetron FM200

FM200 CYLINDER ThornFM200

FM200 CYLINDER Fike FM200

FM200 CYLINDER Siemens FM200

Signage Box and Pressure Switch Pressure Switch for Fed-back Signal

Mode Selection - “System Inoperative” Signal Box Flash AUTO-MANUAL Mode Selection Provided Next to the Panel Outside the Room When Personal Before Enter the Room: - Switch the Auto-Manual Switch to “MANUAL” - “System Inoperative” Signal Box Flash - Switch Back to “AUTO” when Leave the Room

FM200 Operation In Auto Mode Two Detection Zones for Each System Cross Zone Operation Activating Anyone Zone: - Alarm Sound - “Do Not Enter” Sign Flash, Don’t Enter the Room

FM200 Operation in Auto Mode Two Zones Activated: - Two-Tone Sounder Raised - “Evacuate” Sign Flash, Evacuate Room Immediately - A/C in the Room Will Shunt Down - System Start Count Down for 30 Sec. - Gas Discharge to Room After Count Down

FM200 System Operation in Manual Mode When Personal Working inside the Room: One Zone of Alarm Activated and Alarm Sound: - Check Any Fire Happened in Room - Inform Others to Leave the Room if Fire Happened - Go out of the Room, Push the “Manual Release” Switch to Discharge Gas Two Zone Activated: - Evacuate Room Immediately

MAINTENANCE OF AFA AND FM200 SYSTEMS Check Smoke Detectors - Corrosion - Dirty - Generate False Alarm Frequently Check Modules - Simulate Tests to Check the Modules Working Properly

MAINTENANCE Monthly & Annual - To Be Carried-Out By FS Contractor

Introduction of VESDA system What is VESDA… Aspirating Smoke Detection 吸气式烟雾探测

THEINTRODUCTION OF VESDA SYSTEM VESDA ADVANTAGE…

Introduction of VESDA system VESDA Panel VESDA Panel

Introduction of HSSD system Kidde HSSD Panel Kidde HSSD Panel 主機板 鐳射探測器 風機

Introduction of HSSD system Kidde HSSD Sampling Point

Introduction of Pre-action system

Introduction of Pre-action system

THANK YOU

END