COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Preferred Instruments CB-Hawk Replacement System Based on BurnerMate TS Technology A low-cost upgrade for obsolete CB-Hawk systems.
Water & Wastewater Pump Station Control Basic parts: Metering & current limiters Main switch chassis Telemetry & Control Pump controls Questions: -IP.
VFDs Energy Savings A Case Study on Boilers National Grid Solutions & Opportunities Upstate New York Energy Efficiency Conference & Expo April 7, 2011.
Trane Voyager™ rooftop units
Energy Management Practices: Rolling Mills 1. Contents Introduction Energy Intensive Processes & Reduction in Energy Expenditure through Innovative Practices.
Movitrac LTP A General purpose frequency inverter.
MAGNA3 – “built on a proven foundation”
AC 650 the NEW 650 series ac inverters beauty in simplicity...
ABB standard drive Enhanced ACS550
Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.
SmartVFD HVAC, BYPASS, NXL, NXS Introduction
NX Variable Frequency Drives Perfect match for HVAC Field Devices All you need in HVAC Control.
HVAC & WATER Application note
SmartVFD HVAC and BYPASS Introduction. 2 Smart Technology to Reduce Electricity Consumption “Today, our continuing progress is restricted…not by the power.
Variable Frequency Drives VFD Basics
Application Types Variable Torque Constant Torque.
DCS550 Sales Presentation
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
Management and Organisation of Electricity Use Variable Speed Drives Belgrade November 2003.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Make the most of your energy Make the most of your energy SM Add photo in this area Chicago Advanced Energy Stakeholder Series 2014 Mike Mattingly Oct.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
A tour of new features Introducing the PATTERSON VIL-VS.
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
MarsⅡ On-Line UPS Series
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
New Product Enhancements & VERSION 6.06 Firmware Enhancements GV3000/SEGV3000/SE.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
7154 VFD Presentation #5 June 2002 Paul Weingartner.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
Lexium SD2 and Lexium SD3 Stepper Drives and Motors -Lexium SD2 - two-phase range up to 9.2 Nm -Lexium SD3 - three-phase range up to 19.7 Nm.
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
Invensys Controls Europe An Invensys Company EWCM 41x0 family New 32x74.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
HYDRO MULTI-B – Pressure boosting made simple The CU323 1) Power in. 2) Internal Geni 3) Optional CIM Module 4) Analog input 5) PTC terminals 6) DI terminals.
CEE 426 September :05 PM UW Madison Room _____ Engineering Hall Energy in Wastewater Treatment Plants Thomas E. Jenkins, P.E. 1.
© 2012 Eaton Corporation. All rights reserved. PowerXL DG1 Series Drives Josh Gross - Product Manager.
Kaeser Direct Drive ESD Rotary Screw Compressor
© Copyright year ABB. All rights reserved /6/2016 Insert image here ACS800 regenerative drives Product presentation.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Pag. 1 VAT200, General Purpose AC Drive Mini AC Drive VAT200.
Altivar 32 So slim, So smart!
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
ENERGY CONSERVATION IN MOTOR SYSTEMS. Introduction 2.
Intellisys System Manager Intellisys Energy Optimizer
Kaeser Direct Drive CSD Rotary Screw Compressors
Integrated Blower Packages Kaeser Integrated Blower Family.
FUJI ELECTRIC CO.,LTD Power Electronics Business Group Drive Division
Energy Efficient Motors and Variable Speed Drives
The New C55* CPVSd 10-20hp People. Passion. Performance.
Machinery OEM VFD Eaton M-Max VFD
Variable Frequency Drive Savings Calculator Tools
Moving your Control Forward - VFD from Unitronics
Moving your Control Forward - VFD from Unitronics
Presentation transcript:

COMPACT Variable Frequency Drives

Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive amounts of Energy –Electricity = 74% of the energy consumed by commercial buildings (source: US DOE, 2008 Building Energy Data Book) Half of electricity consumed by buildings is used to move air –More than half of the worlds energy is consumed by pumps and fans An electric motor is a fixed-speed machine

Honeywell Proprietary Honeywell.com  VFDs Greatly Reduce Electricity Use (VFDs) significantly reduce electrical consumption –Most pump and fan systems are oversized to account for maximum loads –Capacity usually exceeds demand –Application of VFDs converts systems to variable flow Green House Gas Reduction –80% of commercial building CO 2 emission due to electricity consumption VFDs provide the ability to vary the speed of a motor

Honeywell Proprietary Honeywell.com  What Does a VFD do?  V1 C ~ Motor Variable Frequency Drive (VFD) V3V5 V2V4V6 RectifierDC- circuitInverter unit Power Supply

Honeywell Proprietary Honeywell.com  Affinity laws Express relationship between rotational speed and flow, pressure and power Flow is directly proportional to speed Pressure is proportional to the square of speed Power is proportional to the cube of speed Why Do It? Less Energy = Greater Savings % Power Savings = (%Speed Reduction) 3

Honeywell Proprietary Honeywell.com  Why Do It? Less Energy = Greater Savings % Power Savings = (%Speed Reduction) 3

Honeywell Proprietary Honeywell.com  Opportunities are Everywhere Supply and return fans Cooling Towers Compressors Stairway and parking ventilation Boiler pumps and fans Kitchen Hoods Conveyors Elevators

Honeywell Proprietary Honeywell.com  Optimize Capability, Minimize Waste Many Micro VFDs come loaded with features that do not fit the application Many Micro VFDs do not have the right combination of capabilities SmartDrive COMPACT - chose the options to meet the application: –Interface –Filter –Enclosure –Inputs and Outputs 3 Year Warranty –Longer than all competitors

Honeywell Proprietary Honeywell.com  Optimize Capability, Minimize Waste Chose only the options you need Small installed size Fast installation Intuitive commissioning Easy communication 3-Year Warranty

Honeywell Proprietary Honeywell.com  Available Sizes and Options Power Range –208/240VAC, 1~in/3~out,.25HP to 3HP –460VAC, 3~in/3~out,.5 to 7.5HP –NX series available for other sizes –Other niche markets we are examining 208/240 VAC 3~in/3~out 575VAC 110 VAC Application Interface (API) –Limited API (Standard) Most Applications 1 Analog In, 1 Analog Out, 3 Digital In, 1 Relay Out –Full API Advanced Applications 2 Analog In, 1 Analog Out, 6 Digital In, 2 Relay Out Enclosure - Open Chassis or NEMA 1 Optional EMC Filter

Honeywell Proprietary Honeywell.com  Small Installed Size FRAMEHWD MI16.2”2.6”3.9” MI27.7”3.5”4.0” MI310.2”3.9”4.3”

Honeywell Proprietary Honeywell.com  COMPACT Naming Matrix

Honeywell Proprietary Honeywell.com  Inputs/Outputs and Communications Two Application Interfaces (API) available –Full API LCD, 2 Analog In, 1 Analog Out, 6 Digital In, 1 Digital Out, 2 Relay Outputs –Limited API LCD, 1 Analog In, 1 Analog Out, 3 Digital In, 1 Relay Output Modbus connection standard in both API Additional custom API configurations are available

Honeywell Proprietary Honeywell.com  Standard and Expanded Inputs/Outputs STANDARD EXPANDED

Honeywell Proprietary Honeywell.com  Control Wiring

Honeywell Proprietary Honeywell.com  Fast Installation Din Rail and Screw Mountable Book shelf, Side-by-side installation –No side clearance required Screw Holes Din Rail Clip Book Shelf Mounting

Honeywell Proprietary Honeywell.com  Intuitive Commissioning Click-Wheel Interface Intelligent menu navigation Status Indicators –Ready, Run, Stop, Alarm, Fault Control Indicators –Forward, Reverse, I/O, Keypad, Fieldbus Menu Indicators –Reference, Monitor, Parameter, Fault

Honeywell Proprietary Honeywell.com  Startup Wizard

Honeywell Proprietary Honeywell.com  Startup Wizard

Honeywell Proprietary Honeywell.com  MCA – Micro Communications Adapter Upload and Download parameters without powering the drive PC Connection to the drive for –Commissioning –Control –Monitoring

Honeywell Proprietary Honeywell.com  PC Programming Tool Commission Control Upload/Download Monitor/Trend Faults Print/Save