1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY.

Similar presentations


Presentation on theme: "1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY."— Presentation transcript:

1 1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY

2 Range 1. What is the range of our current Magna? Number of pumps Voltage Flow & Head Temperature Applications 2. What is the range of MAGNA3? Number of pumps Voltage Flow & Head Temperature Applications

3 Range 14 Hydraulic models (11 Single, 3 Twin) Total 37 pumps 115V up to 1HP 208-230V all 14 ° F to 230 ° F Cast Iron and Stainless Water & water/glycol up to 50% Heating, DHW, Solar, Cooling & Geothermal

4 Reliability How long has Grundfos manufactures and sold circulators? How many Alphas/Magnas installed? What is the percentage warranty rate on Magna? Why so reliable? When was the project for Magna3 started? How many hours have the Magna3 been tested?

5 Intelligent Control #1 -or - #2

6 H(ft) P (W) Q (GPM) Intelligent Control – Constant Curve

7 H(ft) P (W) Q (GPM) Intelligent Control - Constant Curve

8 H(ft) P (W) Q (GPM) Intelligent Control - Constant Pressure

9 H(ft) P (W) Q (GPM) Intelligent Control - Proportional Pressure 50 % H Set H Set

10 What is

11 H(ft) P (W) Q (GPM) Intelligent Control - AUTO ADAPT 5 Feet 50 % H MaxH Max

12 H(ft) P (W) Q (GPM) Intelligent Control - AUTO ADAPT 5 Feet Old AUTO ADAPT Set Point New AUTO ADAPT Set Point

13 Intelligent Control – FlowADAPT/FLOWLIMIT Flow Limit 0255075100 FLOW LIMIT FLOWADAPT benefits from the advantages of AUTOADAPT, along with the availability to set a maximum flow limit with FLOWLIMIT. Once the desired maximum flow is set, a remarkable energy saving can be achieved. The MAGNA3 continuously monitors the flow rate ensuring that it is not exceeded. This will save the cost of a separate balancing valve. Potential saving compared to an unintelligent pump Potential saving compared to proportional pressure mode Duty point Additional saving with FLOW LIMIT Performance curve

14 Intelligent Control - CONSTANT TEMPERATURE H(ft) Q (GPM)

15 Intelligent Control - DIFFERENTIAL TEMPERATURE H(ft) Q (GPM)

16 Intelligent Monitoring & Sensing Temperature Speed Flow Power Head Energy BTU History

17 Intelligent Monitoring & Sensing Operating Mode Setpoint Control Mode Alarm/Warning Power and Energy Pressure Head Flow Speed and Frequency Digital Input/Ouput Motor Current Liquid Temperature Operating Hours Total On Time Number of Starts Return Temperature BTU BTU/hr Differential Temperature and more….. CIM Accessory delivers all of this data from the pump to the BMS System Bacnet Lonworks Modbus Profibus SAVES $$$ by eliminating the need for additional monitoring equipment and data point integration in the system

18 Intelligent Interface Show Units in I/P

19 Intelligent Interface - Startup

20 Intelligent Interface – Menu Tabs Show Units in I/P

21 Intelligent Interface – Monitoring MAGNA3 comes with a monitoring function, which makes it possible to keep track of the heat energy distribution and consumption within a system. This avoids excessive energy bills caused by system imbalances. The heat energy meter has an accuracy between +/-1% and +/-10% and makes installing a separate energy metering device within your system superfluous. Temperature input from return pipe

22 Intelligent Interface – Work Log Every duty point and the operational conditions are tracked and stored in the pump. The 3D work log and duty over time curve, provide instant overviews of historical pump performance and operational conditions. The perfect tools for pump optimization, replacement and troubleshooting. Show Units in I/P

23 Efficiency Integrated Grundfos Sensor, Diff. Press & Temperature Optimized 3D Hydraulic Design Permanent Magnet Rotor – Stronger Magnets Composite Rotor Can – reduced magnetic losses Compact Stator – reduces copper and resistance losses Insulation Shell reduces heat loss through pump housing Intelligent control sizes pump for demand

24 EEI What is EEI (Energy Efficiency Indicator)? When was it adopted? What is its future? What does it mean to us (USA)?

25 Load Profiles Flow % Time % 44% 15% 35% 6% 100%75%50% 25% 10 20 30 40 50 60 70 80 90 100

26 Why VFD’s? What percent of the operating time is the demand on a heating system…… A)100%? B)75%? C)50%? D)25%? Why are VFD’s used?

27 Load Profile for EEI Flow % Time % 44% 15% 35% 6% 100%75%50% 25% P avg EEI = --------- x C 20% P ref

28 P ref for EEI P avg EEI = --------- x C 20% P ref

29 Flow % Head 100% 75%50%25% T, 44%T, 35%T, 15%T, 6% Constant Curve Prop. Press. Curve Pavg EEI = --------- x C 20% Pref P avg for EEI H P hyd Max 0.5 x H P hyd Max

30 Energy Efficiency Index is a much better measure of energy usage than BEP EEI 0.27 EEI 0.23 EEI 0.20 EEI 0.17 MAGNA3 65-120 75% Energy Reduction before AUTOADAPT


Download ppt "1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY."