Electrical Code Definitions Understanding Code

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Bonding and Grounding What? Why? How?
Electrical Installation
10 The Service Entrance. 10 The Service Entrance.
National Electrical Code 2008
OSHA Office of Training and Education
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
REVIEW OF CODE BREAKFAST QUESTIONS Brought to you by fellow members who attended the Section Meeting.
Master Examination Practice Drill # O 1. Given: Two (2) rigid metal conduits (RMC) are to support a weatherproof 18 cu. In. device box, with threaded.
DAY 4 CHAPTER 3 CONDUCTOR SIZES,TYPES, ETC.. Continuous Load. A load where the maximum current is expected to continue for 3 hours or more. Continuous.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
Electrical Wiring Residential
OSHA Office of Training and Education
EET Survey of Electronics
Electrical Power Systems
Hazard - Inadequate Wiring
Master Examination Practice Drill # (16) O 1. In commercial and industrial establishments, all 15- and 20- ampere, single-phase, 125 volt receptacles.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Sub Part K Electrical - Installation Safety Requirements (a) Covered. Sections through contain installation safety requirements for.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Copyright 2005 Ted "Smitty" Smith Two Minute Drill Number Three Improving your skill in code Look Up Increasing Speed Drill.
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 25- Residential Improving your skill in code Look Up Increasing Speed Drill.
2005 NEC ® Code Changes Presenter Mark Nowak North East Specification and Project Manager.
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
COMMERCIAL ELECTRICAL (Chapter 11)
Two Minute Drill #10 Copyright 2005 Ted "Smitty" Smith.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
Copyright 2005 Ted "Smitty" Smith Practice Code Look Up Two Minute Drill #6.
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
Electrical Principles and Wiring Materials Unit #31.
Two Minute Drill Number 23- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Electricity By: Mr. Brock. Electrical Safety 1) Always disconnect the circuit to be worked on before anything else and lock the cover to the SEP when.
Two Minute Drill Number 22- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Home Electrical Systems. Behavior Objectives  Define the basics of Electrical Systems  Explain the basic principles of Electricity.  Describe the different.
Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 24- Residential.
2008 Code Drills (C) Copyright 2008 Ted "Smitty" Smith 1 Smitty’s Speed Drills.
Electrical Safety Craig Shurson CSP, ARM Regional Loss Control Coordinator Hortica - The Florists Mutual Company.
Ag. Mechanics for Beginning Teachers
SERVICE ENTRANCE EQUIPMENT
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 21- Residential Improving your skill in code Look Up Increasing Speed Drill.
2014 NEC C ODE C HANGES C LASS P ART III C ALCULATIONS Ted “Smitty” Smith 8/15/2014 E Light Electric Services, Inc.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
ELECTRICAL INSTRUMENTS ( service and utilization )
N.E.C. Installation Techniques and Common Violations
License Examination Practice Drill
2011 Changes Two Minute Drill
Smitty’s Two Minute Drills
Smitty’s Two Minute Drill Mixed Content -05
Practice Code Look Up Two Minute Drill #7
Personal Protective Equipment
AFCI Protection: AFCI Receptacles and the NEC
Chapter Six Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and.
Your Inspection Business Name Goes Here.
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
Overcurrent Protection— Fuses and Circuit Breakers
EET 323 – Electrical System Design Lecture 9: Grounding
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
Objectives Learn about Electricity Pricing Electric systems.
Wiring Circuits Lesson Plan PSTS: C6-7.
2008 Code Drills Health Care Facilities
Presentation transcript:

Electrical Code Definitions Understanding Code Article 100 Electrical Code Definitions Understanding Code

Accessible Wiring components are considered accessible when access is gained without damaging the structure. Example: Conductors connected to switches and receptacles are accessible by a removable plate or device. If you can move this dresser, and it has a cover plate it’s accessible

Accessible (Equipment) Accessible equipment is equipment not guarded by locked doors, elevators, or other. Exception: Overcurrent devices don not have to be readily accessible if located adjacent to the equipment where access is achieved by the use of portable means. Meaning that if you had to get a ladder to reset this breaker, it’s considered accessible equipment as long as it’s not blocked.

Accessible (Readily Accessible) Readily accessible means capable of being reached quickly without have to climb or remove obstacles. Example: A service disconnecting means must be readily accessible or near the entry point of the service conductor. Bushes in front electrical components that come under the code of readily accessible must be cut down.

Accessible (Readily Accessible) Ready accessibility to wiring in luminaires is not required. In most cases, access can be gained through the use of a ladder or scaffolding ect. Conductors: With junction boxes of recessed luminaires can be accessed by removing part of the luminaire. As long as you can remove the trim and access the junction box it will be considered readily accessible!

Appliance Utilization equipment of a commonly built-in standard, installed as a unit such as AC, or a stove….

Not Readily Accessible Capable of being reached quickly for operation, renewal, or inspections without climbing over or having to remove obstacles. A ceiling receptacle installed is not readily accessible, and it must have a ground-fault interrupter (GFCI) .

Arc-Fault Circuit Interrupter A device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by de-energizing the circuit when an arc fault is detected. An AFCI is basically like a GFCI but it will protect the entire circuit from the breaker and back.

Attachment Plug An attachment plug (plug cap) is a device that, when inserted into a receptacle establishes a connection between the conductors of a cord and the receptacle.

Bonding Connected to establish electrical continuity and conductivity. Bonding means that everything is connected or conductivity of the electron through wires.

Bonding Jumper (Main) When metal parts are required to be electrically connected, a reliable conductor (Bonding Jumper) is installed, thereby guaranteeing electrical conductivity. The main bonding jumper is connection at the service between the grounded circuit conductor and the equipment grounding conductor.

Bonding Jumper (Main) An Equipment bonding jumper is the connection between two or more portions of the equipment grounding conductor. Notice the bonding jumper must be made of copper or other corrosion-resistant material. A wire, bus, screw, or similar suitable conductor is acceptable as a main bonding.

Branch Circuit Appliance An appliance branch circuit supplies energy to one or more outlets for the purpose of connecting appliances. These circuits exclude the connection of luminaires (lights) unless they are part of the appliance being connected.

Branch Circuit The circuit conductors found between a circuit’s final overcurrent protective device (breaker) and the circuit’s outlet is called a branch circuit. Branch circuits are divided into four categories: Appliance, General purpose, Individual, and Multi-wire.

Branch Circuit Individual An individual branch circuit supplies only one piece of utilization equipment. Branch circuits are divided into four categories: Appliance, General purpose, Individual, and Multi-wire.

Branch Circuit General Purpose A general purpose branch circuit supplies two or more receptacles or outlets for lighting and appliances. Here we see a general purpose branch circuit.

Branch Circuit Multi-wire A. A voltmeter will not register a voltage when connected to the same ungrounded (hot) phase. B. There a multi-wire circuit must consists of two or more ungrounded (hot) conductors that have a voltage between them. Main panel

Branch Circuit Multi-wire C. The one grounded Neutral conductor of a multi-wire circuit must be connected to the neutral or grounded conductor of the system Main panel

Branch Circuit Multi-wire D. All conductors of a multi-wire branch circuit must originate from the same panel board or similar distribution equipment. Main panel

Branch Circuit Multi-wire E. There must be only one grounded neutral conductor, and there must be an equal voltage between it and each undergrounded conductor of the circuit. See 210.4 A through D for additional requirements…

Branch Circuit Multi-wire Multi-wire circuit consists of one (or more) duplex receptacles, one or more multiple receptacles single or combination. A. A duplex receptacle can be supplied by two branch circuits by removing the tab. This receptacle is fed from a multi-wire branch circuit. B. This tab has been removed to allow separate feeds of each outlet.

Branch Circuit Multi-wire C. Each multi-wire branch circuit must be provided with a means that will simultaneously disconnects all ungrounded (hot) conductors at the point where branch circuits originate.

Branch Circuit Multi-wire D. Although the box contains a multi-wire branch circuit, only one ungrounded (hot) conductor is feeding this duplex receptacle. See 210.70 for switch controlled

Concealed Concealed means rendered inaccessible by the structure of finish of a building Conductors in concealed raceways, even though they become accessible by withdrawing them, are still considered concealed. Raceway containing branch circuit conductors in concrete

Conduit Body A conduit body is a separate portion of a conduit (tubing) system providing access to the interior of the system through a removable cover at a junction. Conduit (Junction) Box

Conduit Body B. FS, FD and larger boxes (cast or sheet metal) are not classified as conduit bodies. C. A single conduit is not permitted as sole support for an FS-type or weatherproof junction box. Show FS boxes in Material PDF FS (Ferris Box Standard) FSS (Ferris Box Continuous)

Continuous Load A load having the maximum level of current sustained for three hours or more is referred to as a continuous load. Office lighting is an example of a continuous load. It can apply to industrial motor as well that run facilities…

Device A unit of an electrical system that carries or controls electrical energy as its principal function is known as a device. Duplexes control outlets of energy, as well as switches and can be used in conjunction such as a garbage disposal…

Enclosed Equipment, conductors, ect., surrounded by a case, housing, fence, or walls and it prevents people from accidentally contacting energized parts is referred to as “enclosed.”

Enclosure Any case, housing, apparatus, fence, or wall surrounding an installation designed to prevent personnel from accidentally contacting energized parts to protect the equipment from physical damage serves as an enclosure. Enclosure for a motor starter

Equipment Equipment is a general term, including fittings, devices, appliances, luminaires, apparatus, machinery, and ect., which is used indirectly or directly on electrical installations. All this can be considered equipment…pretty much anything sold at home depot

Feeder B. Branch Circuits… A. A feeder consists of all circuit conductors located between the service equipment, the source of a separately derived system, or other power supply source and the final branch-circuit overcurrent device. B. Branch Circuits…

Festoon Lighting A. Festoon lighting is a string of outdoor lights suspended between two points.

Festoon Lighting B. Overhead conductors for festoon lighting shall not be smaller than 12 AWG unless supported by messenger wires…

Festoon Lighting C. Messenger wire(s), together with insulators is used to support conductors in all span exceeding 40ft (12m) in length. They can’t be attached to any fire escape, downspout or plumbing equipment.

Fitting A. A fitting is an accessory, such as a locknut or bushing, whose function is primarily mechanical, rather than electrical in nature.

Grounded Conductor A. A grounded conductor is a system or circuit conductor that is intentionally grounded. Ground is defined as earth.

Grounded Conductor Cont… B. Grounded (grounding) is defined as being connected to ground or to a conductive body that extends to the a ground connection.

A. Main Equipment B. Conductive Path C. Grounded Neutral D. Bonding Jumper E. Bonding Conductor F. Grounding Electrode Conductor G. Grounding Electrode Grounding Electrode: The path installed with all the parts of the path A – G.

Guarded Guarded is defined as covered, shielded, fenced, enclosed, or otherwise protected by barriers, rails, screens, mats, or a platform removing the approach of contact by people or persons.

In Sight A. NEC defines in sight from, within, or within sight to the applied equipment and indicates that specified items or equipment is visible and not more than 50 Ft. apart. B. A motor disconnecting means must be located in sight from the motor location as required by 430.102 NEC

Lighting Outlets A. An outlet intended for the direct connection of a lamp holder or luminaire is called a lighting outlet. NEC

Location Damp A. Damp locations are those subject to moderate degrees of moisture. Exterior protected locations under canopies, roofs, porches, and similar sites are considered damp locations. NEC

Location Dry A. Dry locations are those not normally subject to moisture except on a temporary basis such as a building under Construction… NEC

Luminaire A luminaire is a complete lighting unit consisting of a light source such as a lamp or lamps, together with the parts designed to position the light source and connect it to the power supply. It may also include parts to protect the light source ballast or distribute the light. A lamp holder itself is not a luminaire. NEC

Multi-Outlet Assembly A. A surface, flush, or freestanding raceway designed to hold conductors and receptacles (in the field or the factory).

Location Wet A. Installations in any of the following categories are wet locations, underground, within concrete slabs, in masonry areas subject to saturation or liquids and in locations unprotected from weather.

Neutral Conductor or Point A. The neutral point is the common point on a Wye-connection in a polyphase system.

Neutral Conductor or Point B. The neutral point is the midpoint on a single-phase portion of a 3 wire system.

Neutral Conductor or Point C. The neutral point is the midpoint on a single-phase portion of a 3 phase Delta System.

Neutral Conductor or Point D. The neutral point is the midpoint on a single-phase portion of a 3 wire direct current system.

Outlet A point in a wiring system from which current is taken to supply utilization equipment is known as an outlet.

Overcurrent Protection Device Overcurrent Protection (Breaker) A branch-circuit overcurrent protection is a device capable of protecting feeders, branch circuits, service equipment between its rated current and its interrupting rating.

Plenum (Space) A. The space above a suspended ceiling used for environmental air-handling purposes is an example of other space used for environmental air described in 300.22

Plenum (Space) B. A compartment or chamber having one or more attached air ducts and forming the distribution system is known as a plenum.

Receptacle A. A contact device installed at an outlet for the connection of an attachment plug is a receptacle.

Separately Derived System B. A separately derived system is a premises wiring system whose power is derived from a source of electric energy or equipment other than a service. It has no direct connection from circuit conductors.

Service A. The conductors and equipment that deliver energy from the serving utility to the wiring system of the premises are called the service…

Service Conductors A. The conductors from the service point to the service disconnecting means are known as service conductors…

Service Drop A. The overhead conductors between the utility electric supply and the service point.

Service Equipment A. Service equipment is that equipment (circuit breaker), switches, fuses, and other that is necessary to constitute the main control and cutoff that is connected to the load end of the service conductors.

Service Lateral A. The service lateral is the underground conductors between the utility electric supply system and the service point.

Service Point A. The service point is the point of connection between the facilities of the serving utility and the premises wiring.

Special Permission AHJ Special permission is the written consent of the authority having Jurisdiction or the AHJ who enforce the NEC and grant variances in the code (building department).

Check The Knowledge… Multi-Wire A ____ branch circuit supplies two or more receptacles or outlets for lighting and appliances?

Check The Knowledge… False Not readily accessible means you don’t have to worry about it at all or ever have to service it? T/F

A grounded conductor is a jumper to the main box on a feeder tube. Check The Knowledge… False A grounded conductor is a jumper to the main box on a feeder tube.