Augmenting Sprinkler Systems

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

Strategy and Tactics with Limited Staffing
Fire Protection Systems
Chapter 16 Lesson Goal After completing this lesson, the student shall be able to operate various fire detection, alarm, and suppression systems and operate.
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
Slide 5-88 Side A Exposure Side A Walk-around 100 R Street Command Sequence # 8.
Slide 5-1 UNIT 5: WATER SUPPLY, FIXED FIRE PROTECTION SYSTEMS, AND SALVAGE.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Fire protection systems
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
Wet Sprinkler Systems Identifying components of, and inspection and testing procedures.
Augmenting Fire Standpipe Systems
Blackwood Fire Company
N.F.P.A. 13R Justin Bohlmann FIR-204.
4/15/2017 7:34 AM Fire Sprinkler Systems Prepared by Thomas Bartsch Chief Fire Inspector (ret) Former Chief of Department, Valley Stream, NY © 2007.
State of Kuwait 3rd Intl Fire & Safety Conference & Expo 4-6 March 2014 Building Performance for Emergency Response Incident Examination and Tactical Response.
Pumping Apparatus Driver/Operator
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Automatic Sprinkler System. Importance of Sprinklers First line of protection – small fires Enhanced protection Business protection – less interruption.
Training On Demand. Purpose To provide fire fighters at an emergency incident a team with pre-assigned duties aimed at rescuing downed, lost or trapped.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
Fire Suppression Techniques IFSTA Chapter 14
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Purpose of Standpipe and Hose Systems
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
C L A S #4 Driver Operator Refresher Training.
 Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
Fire Protection Engineering and Building Code Analysis Presented By: Harold D. Hicks P.E. President Use space bar or left mouse button to move through.
Automatic Sprinkler Systems
CVFD Training – Fire Protection Systems
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
Intermediate SFFMA Objectives: – Hrs received.
Tactics.  Garden Apartments  Town Homes  Apartment Buildings 2.
Module C Sprinkler systems (4-20)
PREINCIDNET PREPARATION. OBJECTIVES Properly calculate required fire flow for structures using the National Fire Academy Fire Flow Formula. FIRE FLOW.
Water Supply.
Managing Company Tactical Operations
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Fire Department Hydraulics
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
Pre Incident Planning and Related Loss Reduction Strategies
United States Fire Administration Chief Officer Training Curriculum Operations Module 9: Nursing Home Simulation Exercise.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
High Rise October DISPATCH E82, E83, E81, E97, E86, E95, T82, T98, R81, R83, R97, B8, B9, OSO respond to a reported structure fire at 777 W. Lake.
1 © 2009 Delmar, Cengage Learning Special Concerns in Fire Fighting Chapter 6 Page 133.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
SIZE-UP The systematic process consisting of the rapid, yet deliberate, consideration of all critical fire ground factors that leads to the development.
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
TRANSITION TO COMPANY OFFICER Arlington Fire Department Officer Development September 2000.
Part C: Class D Fires and Tactical Considerations.
Chapter 6 ID 234 Building Codes Fire Suppression.
1. 2  Dispatch information  Day of week  Time of day  Pre-incident survey  Observations  Building construction, layout  Bystanders.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
ME444 ENGINEERING PIPING SYSTEM DESIGN
GENERAL ORDER INITIAL OPERATIONS AT HIGH RISE STRUCTURE FIRES HOWARD COUNTY DEPARTMENT OF FIRE AND RESCUE SERVICES AND FIFTH DISTRICT VOLUNTEER.
Fireground Operations: Staging Union County SOG 3.24.
Fire Ground Roles & Responsibilities On scene reports & Truck and seat assignments.
Welcome To High Rise Operations ! Like The Jefferson's...
FVCC Fire Rescue Fire Control.
NEW COMPLIANCE REGULATIONS
Sprinkler Systems: Review and Response Considerations
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Augmenting Sprinkler Systems By Michael Stevens FIR 204 December 1st, 2009

What We Will Talk About Importance of pre-incident planning What to look for during pre-incident planning Fire Department connections Why sprinkler systems should be augmented. Importance of establishing SOGs for operations in buildings containing sprinklers. Fire Department operations in buildings containing sprinklers. What we will talk about today…. Importance of pre-incident planning – Why FDs should conduct pre-incident plans for buildings containing sprinklers What to look for – Various items to locate and document during pre-incident planning. Fire Department connections – What they are and why they are there. Why sprinkler systems should be augmented. Importance of creating SOGs for operations in these buildings. FD operations in buildings with sprinklers.

Pre-Incident Planning

Why should you pre-plan? Opportunity to establish working relationship with occupant and/or other personnel. Opportunity to survey site and gather information. Provides chance to develop/ modify a plan. Reduces number of surprises encountered during actual emergencies. Why should you pre-plan? Chance to establish working relationship with occupant/ other personnel (maintenance or technical specialists) Chance to survey site and gather information pertinent to FD operations. Provides a chance to develop or modify plan of attack. Reduces number of surprises you may encounter on actual emergency.

What to Look For Things to note: Size of buildings Nature of occupancy Presence, type, and condition of: Sprinkler system(s) Standpipes Fire detection and alarm systems Things to note: Overall size of buildings Nature of occupancy – What kind of hazard does this present to FD operation? Presence, type, condition of: Sprinkler system Standpipes - Are there any? What kind are they? How do we use them? How can we use them to our benefit? Are they in good working condition? Fire detection and alarm systems – Are there any? How do they work?

What to Look For (cont.) Water supply Required/ available fire flow Location(s)/ reliability of supply Location and condition of Fire Department connection. Obstructions Thread compatibility Location, type, and operation of sprinkler control valves. Water supply – Required and available fire flow – How much water will this need vs. how much do we have available Location/ condition of FDC – Gotta find it first. Any obstructions? Are threads compatible with our hoses? Sprinkler control valves – Where are they? What kind are they? How do they work?

What to Look For (cont.) One- and two-family dwellings equipped with sprinklers do not have FDCs. FDCs can be found in: Industrial occupancies Commercial occupancies Multi-family dwellings Healthcare facilities 1 and 2 family dwellings equipped with sprinklers do not have FDCs. FDCs can be found in industrial and commercial occupancies, multi-family dwellings (apartments), and healthcare facilities.

FIRE Department connections

Fire Department Connections FDCs supply: Sprinkler systems Automatic Non-automatic Standpipe systems Both sprinkler and standpipe systems Known as combination systems May be wet or dry systems FDCs supply: Sprinkler systems – both automatic and non-automatic Standpipe systems Sprinkler and standpipe systems – Known as combination systems Combo systems can be wet or dry systems

Combination wet and dry system. Wet system on left/ dry on right. 2 zones. Dry system is in roof, wet system is interior of building.

Fire Department Connections Connection usually by-passes control valve. System can be used regardless of position control valve is in. Location: Should be one located near main entrance of building. Others may be located at various locations around building. For use by additional companies. When system is divided into zones. FDCs usually by-pass control valve in the system so it can be used regardless of position control valve is in. Should be located near main entrance of building. Others may be located at various locations around building for use by additional companies or if system is divided into zones.

What You Are Looking For

What You Are Looking For FDCs should be clearly marked. FDC stands for Fire Department Connection FDC does not mean: Parking for the “First Due Cop” Parking “For Da Chief” FDCs should be clearly marked – signs of various sizes with various markings

Is this clearly marked? Could you find this at 2am?

What It Can Tell You Kind of system it supplies. If trusses are present. Where trusses are located. Type of construction. If water is flowing. What it can tell you…. Kind of system it supplies – Sprinklers/ standpipes/ combo system. Noted on a plate around the connection or connection itself. Truss identification signs – If trusses are present, where they are, type of construction. Not present in every community. If water is flowing. – Water flow alarms are usually located near FDC. Sounding water flow alarm does NOT guarantee fire condition. Could be from broken pipe or sprinkler head.

FDC for combination system

FDC Problems Missing caps Defective/ incompatible threads Debris in connection Tight caps Frozen female swivels Broken/ jammed clappers Can use spare male cap to close one side of connection due to clapper valve malfunction. FDC problems include: Missing caps Defective or incompatible threads Debris in connection Tight caps Frozen female swivels Broken/ jammed clapper valves – use spare male cap to close one side of connection if this happens

Why should you augment the system?

Why They Should Be Augmented Water supply may be insufficient Water supply may be overtaxed when large number of sprinkler heads open. Increase overall water flow at each sprinkler head. Why they should be augmented… Insufficient water supply – Water mains or private tanks – modifications or change in occupancy Water supply may be overtaxed due to large number of sprinkler heads that are activated. Increase overall water flow at each sprinkler head.

Why (continued) “Fixed extinguishing systems may reduce the need for interior attack lines but increase the need for system support. Standpipe systems may allow firefighters to carry hose packs into the building rather than lay long attack lines from an engine outside.” (Goodson and Sneed 240) Quote – Goodson and Sneed

Why (continued) They can make our job easier. May reduce risk to occupants and firefighters. Someone wise once said: “Ninety-six percent of fires in sprinkled structures are controlled by the sprinkler system.” ( Dave Walsh – November 3rd, 2009) They can make our job easier- by knocking down or extinguishing fire in its incipient stage. May reduce risk to occupants and firefighters. Quote – 96% of fires in sprinkled structures are controlled by the sprinkler system.

Water Flow

Water Flow “Sprinkler heads are designed to operate at a minimum of seven psi pressure.” (Crapo 79) At seven psi, a sprinkler with ½- inch opening should flow fifteen gpm. As pressure increases, so will the flow. To calculate gpm from sprinkler head: ½ residual psi + fifteen ½ (30)+15 = 30 gpm ½ (40)+15 = 35 gpm ½ (50)+15 = 40 gpm Water flow… Quote – Sprinkler heads are designed to operate at minimum of 7psi pressure. At 7psi, a sprinkler with ½- inch opening should flow 15gpm. As pressure increases, so will the flow. To calculate sprinkler head gpm : ½ residual psi plus fifteen = gpm

Water Flow “The recommended course of action for a sprinkler system is to pump a set pressure, usually 150 psi is recommended.” (Crapo 178) Use set pressure instead of flow calculations because there is no way to determine: Number of activated heads Location of activated heads How much water is flowing Quote – Pump 150 psi into sprinkler system – This is true for the industry standard, unless marked otherwise. Use a set pressure because no way to tell: number of open heads location of open heads amount of water flowing

Water Flow Do NOT over pump the system. Too much pressure in system will cause water to exit the sprinkler head at too high a velocity. This will cause water to atomize. Droplets will be too small and light to penetrate to seat of the fire. Do not over pump the system. Too much pressure will cause water to exit at too high velocity. Causes water to atomize and be too small/ light to penetrate to seat of fire.

Non-Automatic Sprinklers Usually found in cellars and sub-cellars of older commercial buildings. Depend solely upon FD for water supply. May contain: Fusible links Open sprinkler heads Perforated pipes Non-automatic sprinklers… Found in cellars and sub-cellars of older commercial buildings FD is only water supply May contain fusible links, open sprinkler heads, or perforated pipes

Combination Systems Sprinkler heads and standpipes use common riser. If conducting interior operations: Connect first supply line to standpipe Connect second supply line to sprinkler system Safety of personnel should always be TOP PRIORITY!! Combination systems… Sprinkler heads and standpipes share common riser. If conducting interior ops: Connect 1st supply line to standpipe Connect 2nd supply line to sprinkler system Personnel may be using standpipes for interior ops Safety of personnel is TOP priority!!!

Effective Fire Stream Three critical factors of effective fire stream: Must flow sufficient gpm to absorb BTUs being generated. Water must be applied at the correct point(s). Water must be applied in correct form. Water allowed to vaporize will absorb 7.7 times more heat than water that does not vaporize. Whether you are using sprinklers or standpipes, you are trying to produce an effective fire stream. 3 critical factors: Must flow sufficient gpm to absorb BTUs Correct application points Applied in correct form – Does not mean always use smooth bore or fog nozzle. Use what is appropriate for situation. Smooth bore nozzle is capable of penetrating a deep seated fire.

One Meridian plaza high-rise fire Case Study

One Meridian Plaza Occurred February 23rd, 1991 in Philadelphia, PA Fire started on 22nd floor. Incident Commander had little pre-plan information Less than half of building had sprinklers. Service floors below grade Floors 11, 15, 30, 31, 34, 35, and 37 FD attempted standpipe operation, but did not produce effective fire streams due to PRVs. Occurred February 23rd, 1991 in Philadelphia, PA Started on 22nd floor Little pre-plan info available prior to incident Less than half of building had sprinklers Standpipe operation was ineffective due to pressure reducing valves that FD did not know how to operate.

One Meridian Plaza Fire burned floors 22 through 29 and killed three firefighters. Fire was stopped at 30th floor by activation of ten sprinkler heads. If each head delivered max flow of 25 gpm, ten heads delivered 250 gpm. Same flow as one 2 ½- inch hose line Fire burned floors 22 through 29 and killed three FFs. Fire was stopped by TEN sprinkler heads on 30th floor. Exact flow of each head is not known, but if each head delivered max flow of 25 gpm, then 10 delivered 250 gpm. The same flow as one 2 ½- inch hose line.

Standard operating guidelines (Sog)

SOGs “Departments protecting properties with fire protection systems should have SOPs addressing operations in these buildings.” (Cote 1:7-338) Fire department operations could have negative impact on sprinkler system water supply. Sprinklers cool fire gases Fire may not vent itself prior to FD arrival Fire gases and smoke may drop to floor SCBA will be necessary Quote – Departments should have SOPs addressing operations in buildings with sprinklers. FD ops could lower the pressure in sprinkler systems water supply. Consider using an alternate water main/ source. Sprinklers cool fire gases – Fire may not be vented. This will produce an environment with much more smoke and fire gases. Addressing ventilation and respiratory protection requirements is critical.

SOGs Fire departments can refer to NFPA 13E – Recommended Practice for Fire Department Operations in Properties Protected by Sprinklers and Standpipe Systems for guidance when developing their own SOGs. FDs can refer to NFPA 13E for guidance on SOGs.

SOGs (example) Upon arrival, first-in engine company should: Locate FDC Locate nearest suitable water supply Connect either two 2 ½- inch or one 3- inch hose line to FDC Wait for confirmation prior to charging system SOGs example: First-in engine company should: Locate FDC, locate nearest suitable water supply, connect to FDC, and wait for confirmation that augmentation is required prior to charging system.

SOGs (example) Interior crews should: Locate fire Determine if charging system is necessary Check sprinkler control valves, if accessible Make sure fire pump is running, if applicable Interior crews should: Locate the fire Determine if charging the system is necessary. – Could be due to broken pipe or head Check control valves – make sure they are open Fire pump – if there is one, make sure its running.

Control Valves

Control Valves “The sprinkler system control valve should only be shut down on orders from the Incident Commander once it is determined that the fire has been controlled and hose lines are in position.” (FDNY 4) Quote – Control valve should not be shut down until fire is under control, hose lines are in place, and IC gives the orders.

Control Valves Four types: Outside Screw & Yoke (OS&Y) Post Indicator Valve (PIV) Wall Indicator Valve (WIV) Butterfly Type Indicating Valve OS&Y and PIV are most commonly encountered. May also be found in standpipe systems. Used as section or zone control valves. Four types: OS&Y, PIV, WIV, Butterfly OS&Y and PIV are most commonly encountered. May also be found in standpipe systems.

Control Valves FD personnel with portable radios should use control valve to shut system down: After fire is declared under control After given orders by IC After hose lines are in place To reduce water damage FD personnel with radios should shut system down: After fire is under control After IC tells them to After hose lines are in place To reduce water damage

review

What We Talked About Why pre-incident planning is important What to look for when pre-planning FDCs Why FDs should augment sprinkler systems Importance of establishing SOGs for ops in buildings with sprinklers. When/ how to shut sprinkler systems down. Pre-planning – So we know what we’re dealing with. Discussed One Meridian Plaza Fire What info to look for – FDCs, water supply, types of systems, and control valves FDCs – Location, problems (obstructions, threads) Why we should augment systems – Required fire flow, making sure system is not overwhelmed SOGs – Sprinklers can change the way we fight fire. Use them to our advantage. When/ how to shut systems down – control valves, waiting for IC to give order

Thanks for your time & attention Stay safe and have a great day!!!

Works Cited Cote, Arthur E., P.E. ed. Fire Protection Handbook. 19th ed. 2 vols. Quincy: National fire Protection Association, 2003. Crapo, William F. Hydraulics For Firefighting. Albany: Delmar, 2002. Goodson, Carl, and Marsha Sneed, eds. Fire Department Company Officer. 3rd ed. Stillwater: Fire Protection Publications, Oklahoma State University, 1999.

Works Cited (cont.) Murnane, Lynn, and Tom Ruane, eds. Fire Detection and Suppression Systems. 3rd ed. Stillwater: Fire Protection Publications, Oklahoma State University, 2005. New York. Fire Dept. Engine Company Operations, Chapter 10, Sprinkler System Operations. New York: Fire Department City of New York, 1997. Norman, John. Fire Officer’s Handbook of Tactics. 3rd ed. Tulsa: PenWell, 2005.

Works Cited (cont.) Routley, J. Gordon, Charles Jennings, and Mark Chubb. Highrise Office Building Fire, One Meridian Plaza, Philadelphia, Pennsylvania. Quincy: National Fire Protection Association, 2001. Walsh, David K. Class lecture on sprinkler systems. Dutchess Community College. 3Nov.2009.