3AH5 Vacuum Circuit-Breaker For Standard Applications

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Medium-Voltage Switchgear - Then and Now -
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Inspection & Preventive maintenance of breakers
M iniature circuit breakers to UL 489
IEC Short-circuit current making and breaking tests Taiwan-European HVAC apparatuses Accreditation and Certification forum Harethe El Ouadhane.
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
During fault behavior of circuit breaker
Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
SMITH_USA_Author_ALPHA1_BLOCK1_Question 1-6 Barcelona May Question 1-6 Are There Fundamental Performance Limits for Vacuum Breaking Technology?
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
Assumption University Thailand EE4503 Electrical Systems Design Introduction 1.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
SF6 load-break switch-disconnector
MV SF6 circuit-breakers for secondary distribution
Multi-function apparatus for secondary distribution
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
1111Challenges for reliable offshore transformersTRANSFORMING YOUR NEEDS INTO SOLUTIONS Challenges for Reliable Offshore Transformers Dr. Jan.
Standardization Aspects in UHV Networks New Delhi, January 2009 Denis Dufournet Chairman IEC TC17 Member CIGRE WG A3-22.
Pole Mounted Switch Disconnector NPS
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Frankfurt (Germany), 6-9 June 2011 Louise Jakobsen, Danish Energy Association – Denmark – Session 3 – Paper 0811 Louise Jakobsen, Danish Energy Association.
Medium Voltage Outdoor Apparatus Portfolio
PowerIT Air Insulated Cubicle Uniswitch
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
Submitted to: Submitted by:
Simple Circuits & the Transfer of Electrical Energy
Air Blast Circuit Breaker
Main contacts closed – RED Colour with ON
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Basic study of a switch Unit 3.Lesson 3. A switch Purpose A switch is a mechanical device used to connect and disconnect a circuit at will Parts seen.
Switchgear for Primary Distribution
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
6 Week industrial Training Presentation
Presentation CERN SPAIN | ITALY | FRANCE | GERMANY | MEXICO | USA | BRAZIL | UAE | QATAR | OMAN | SAUDI ARABIA jema.es.
© 2008 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Electrical.
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
VMCL ELECTRONIC DIVISION.
POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS
Sub Station.
SUB-STATIONS.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
AIR CIRCUIT BREAKER.
PRESENTATION ON SUMMER TRAINING PROGRAM
Name, department/event, date
Circuit Breakers & Reclosers
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
POWER SYSTEM ANALYSIS INTRODUCTION.
SION Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
EHV Transmission Equipments
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Presentation transcript:

3AH5 Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage © Siemens AG 2009 Sector Energy, Business Unit Medium Voltage

3AH5 Vacuum Circuit-Breaker Directory Technical Data Portfolio Product Features Details Applications September 2009

3AH5 Vacuum Circuit-Breaker 1. Technical Data Rated voltage up to 36 kV Short-circuit breaking current up to 31,5 kA Operating current up to 2500 A Mechanical operating cycles 10,000 (M2) Electrical operating cycles 10,000 (E2, C2) September 2009

3AH5 Vacuum Circuit-Breaker 2. Portfolio September 2009

3AH5 Vacuum Circuit-Breaker 3. Product Features Main Data 12, 17,5, 24 & 36 kV 800 to 2500 A 13,1 to 31,5 kA Up to 10,000 mechanical operating cycles Type tested according to IEC 62271-100 Your Benefit Usage for all standard application in medium voltage Compact dimensions Maintenance free up to 10,000 operating cycles September 2009

3AH5 Vacuum Circuit-Breaker 3. Product Features Column construction Vacuum interrupters are vertically arranged Free convection possible Solid insulation material is minimised as far as possible Your Benefit High mechanical stability Compact dimensions No forced-cooling up to 2500 A Very low fire load Easy access to all parts September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Hand crank coupling Push button “ON” Indicator „Closing spring charged“ Counter for “Operating cycles” Push button “OFF” Indicator „Closed/Open“ September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Operating unit Cooling element Auxiliary switch Gearbox Shunt release Opening magnet Closing spring September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Secondary equipment Basic equipped Fully equipped September 2009

Comparison: Use of Insulation and Plastics 3AH5 Vacuum Circuit-Breaker 4. Details Comparison: Use of Insulation and Plastics 3AH5 column construction SION shell construction Competition embedded pole 12 kV 4 kg 13 kg 17 kg 14 kg 23 kg 2500A Phase barrier drive 10 kg PMA 160 mm Phase barriers 17,5 kV 16 kg PMA 150/160 mm   Phase barrier contact arms September 2009

Applications for 3AH5 5. Switching of Standard Applications Requirements Switching of transformers, drives, capacitors, filter circuits, overhead lines and cables Synchronising of parallel networks Rapid load transfer of consumers to other incoming feeder Auto-reclosing in overhead lines to clear transient faults or short-circuits Switching of short-circuits Industry Application “Refinery” September 2009

Thank you very much for your attention! Please press ESC to return to the overview. September 2009