1 Switchgear for Primary Distribution
Product: SIMOPRIME Energy Distribution Medium Voltage

2 Air-insulated, metal-enclosed, metal-clad Medium Voltage Switchgear
SIMOPRIME Air-insulated, metal-enclosed, metal-clad Medium Voltage Switchgear

3 SIMOPRIME Agenda Overview Benefits How You Will Get the Benefits Summary

4 SIMOPRIME: Overview Typical applications: Power Generating stations Power Distribution centres Industrial switching applications

5 SIMOPRIME: Technical Details
SIMOPRIME - Rated values Rated voltage 7.2 kV 12 kV 15kV 17.5 kV Rated frequency Hz 50/60 Rated power frequency- Withstand voltage kV 201) 281) 35 38 Rated lightening impulse withstand voltage 602) 753) 95 Rated short circuit breaking current max. kA 40 Rated short time withstand current, 3s Rated short circuit making current max.kA 100/104 Rated peak withstand current Rated normal current of Busbars max. A 3600 Rated normal current of Feeders 36004) 1-) Higher values for GOST standards as option 2-) 40kV for open contact gaps of Vac. Contactor 3-) 60kV for open contact gaps of Vac. Contactor 4-) max. 400A for contactor feeders

6 SIMOPRIME: Technical Details
Rated voltage 7.2 kV 12 kV 15 kV 17.5 kV Classification according to IEC : Partition class PM Service continuity category LSC2B Internal arc aspects Class IAC max. kA 40 s 0.1/1.0 Accessibility A Classification AFLR Accessibility of compartments according to IEC : Busbar compartment Tool based Switching device compartment Interlock based accessible Connection compartment (front access) Tool based and Interlocked based accessible Connection compartment (rear access) Low voltage compartment

7 SIMOPRIME: Technical Details
Rated voltage 7.2 kV 12 kV 15 kV 17.5 kV Degree of protection for enclosure IP4X / IP511) IP4X / IP511) Dimensions: Width mm 6002)/8004) 600/8004) Depth 1860 3) 1860 Height with IAC 0.1 Sec. 2253 Height with IAC 1.0 Sec. 2425 Height with IAC 1.0 Sec (40kA) 2460 Installation details: Installation Indoor Number of phases 3 Number of busbars Single Cable access Front/Rear Cable entry Bottom Maximum site altitude above sea level m 1000 1-) Applicable for non-ventilated panels 2-) 435mm for Slim CFC Panel ) 1837mm for Slim CFC Panel ) 40kA panels only with 800mm

8 SIMOPRIME: Overview – Simoprime with 3AH5
1 = Door of low voltage compartment 2 = Opening for locking or unlocking low voltage compartment door 3 = Capacitive voltage detection system for feeder and busbar 4 = High voltage door of switching device compartment 5 = Inspection window for checking the switching device position 6 = Opening for locking or unlocking the high voltage door 7 = Opening for mechanical charging of circuit breaker closing spring 8 = Opening for manual (ON / OFF) of the circuit breaker 9 = Inspection window for reading the indicators 10 = Door handle 11 = Opening for switching device truck operation 12 = Opening for earthing switch operation

9 SIMOPRIME: Overview – Simoprime with 3AH5
13 = Pressure relief duct 14 = Busbars 15 = Bushings 16 = Post Insulators 17 = Current transformers 18 = Make-proof earthing switch 19 = Cable sealing ends 20 = Voltage transformers 21 = Earthing busbar 22 = Low voltage plug connector 23 = Vacuum Interrupters 24 = Switching device truck A: Switching device compartment B: Busbar compartment C: Connection compartment D: Switching device truck E: Low voltage compartment

10 SIMOPRIME: Overview - Simoprime with SION
1 = Door of low voltage compartment 2 = Opening for locking or unlocking low voltage compartment door 3 = Capacitive voltage detection system for feeder and busbar 4 = High voltage door of switching device compartment 5 = Inspection window for checking the switching device position 6 = Opening for locking or unlocking the high voltage door 7 = Opening for mechanical charging of circuit breaker closing spring 8 = Opening for manual (ON / OFF) of the circuit breaker 9 = Inspection window for reading the indicators 10 = Door handle 11 = Opening for switching device truck operation 12 = Opening for earthing switch operation

11 SIMOPRIME: Overview – Simoprime with SION
13 = Pressure relief duct 14 = Busbars 15 = Bushings 16 = Post Insulators 17 = Current transformers 18 = Make-proof earthing switch 19 = Cable sealing ends 20 = Voltage transformers 21 = Earthing busbar 22 = Low voltage plug connector 23 = Vacuum Interrupters 24 = Switching device truck A: Switching device compartment B: Busbar compartment C: Connection compartment D: Switching device truck E: Low voltage compartment

12 SIMOPRIME: Overview Basic design options: Cable entry: from bottom

13 Switch fuse disconnector panel
SIMOPRIME: Overview Product range: Rated voltage 7.2 kV 12 kV 15/17.5 kV Circuit breaker panel X Contactor panel 1) - Metering panel Bussectionaliser Switch fuse disconnector panel 1-) Slim contactor panel ( 435mm width ) is available for 7.2kV IEC

14 SIMOPRIME: Overview Vacuum circuit breaker panel Disconnecting panel
Vacuum contactor panel

15 SIMOPRIME: Overview Bussectionaliser Metering panel

16 SIMOPRIME: Benefits Peace of Mind 2. Saves Lives 3. Increases Productivity 4. Saves Money

17 SIMOPRIME: Benefit No. 1 Peace of Mind

18 Peace of Mind: How? Fulfilling all the mandatory type tests requirements of new IEC 1. Tests to verify the insulation level ( power frequency and impulse ). 2. Temperature rise and measurement of resistance of circuit. 3. Tests to prove the withstand capability of main and earthing circuits subjected to rated peak and short time withstand currents. 4. Test to prove the making and breaking capacity of the circuit breaker inside the switchgear panel.

19 Fulfilling all the mandatory type tests requirements
Peace of Mind: How? Fulfilling all the mandatory type tests requirements of new IEC 5. Test to prove the satisfactory operation of switching devices and removable parts. 6. Tests to verify the protection of persons against access to hazardous parts and the protection of the equipment against solid foreign objects + The stringent requirement of Internal arc testing as outlined in new IEC

20 Peace of Mind: How? SIMOPRIME can be freely used on GOST standard countries. The certification is valid to 6kV and 10kV systems

21 Peace of Mind: How? 3AH5 VCB SION VCB 3AH5 and SION breaker tested inside the panel, means higher operational reliability.

22 Peace of Mind: How? Preventive mechanical interlocks avoid incorrect operations.

23 Peace of Mind: How? Preventive Mechanical Interlocks 1. Operation of switching device is possible only when the switching device truck is in end position. 2. Moving of switching device truck from SERVICE to TEST is possible only when the switching device is switched OFF.

24 Peace of Mind: How? Preventive Mechanical Interlocks 3. Moving of switching device truck from TEST to SERVICE position is possible only when the switching device is switched OFF, the low voltage plug is connected and the earthing switch is switched OFF. 4. Operation of earthing switch is device truck is in TEST position.

25 systems and can be replaced on site.
Peace of Mind: How? A redundant force ventilation system will automatically work in case of a fail on the main ventilator. Both ventilators have independent systems and can be replaced on site.

26 Peace of Mind: How? Earthquake qualification IEC UBC zone 4 Transelec requirements (Chile) No damage or an unwanted operation during an unexpected earthquake

27 Vacuum interrupters - a highly proven and widely
Peace of Mind: How? SF6 CB: 22% MOCB: 14% VCB: 64% World Market shares - Medium Voltage Switching technologies Vacuum interrupters - a highly proven and widely used technology, world-wide.

28 + Freedom from manufacturer’s monopolistic policies Open communication
Peace of Mind: How? Freedom from manufacturer’s monopolistic policies + Standard Instrument transformers Open communication protocol relays

29 Peace of Mind: How? ISO Certification Siemens has consistent quality standards for all products, processes and manufacturing centres.

30 A true international switchgear based on global
Peace of Mind: How? Europe S o u t h A m e r i c a A s i a Global village a reality A true international switchgear based on global best practice sharing and experience.

31 Peace of Mind: How? s One word says it all!

32 Peace of Mind: Summary Benefit Features 1. Peace of Mind 1.1 Factory assembled, fully type tested switchgear as per IEC 1.2 GOST certified 1.3 Testing of VCB inside the panel 1.4 Preventive mechanical interlocks 1.5 Redundant forced ventilation 1.6 Earthquake proof

33 Peace of Mind: Summary Benefit Features 1. Peace of Mind 1.7 Use of vacuum switching technology 1.8 Use of world wide available parts 1.9 Quality according to ISO 9001 1.10 Design based on global best practice sharing and experience 1.11 Siemens guarantee

34 SIMOPRIME: Benefit No. 2 Saves Lives

35 How soon: As soon as you energize Siemens SIMOPRIME switchgear!
Forecast: Saves Lives How many: Even one life! How soon: As soon as you energize Siemens SIMOPRIME switchgear!

36 Saves Lives: How? All operations behind closed door 1. All switching operations including emergency manual operations 2. Feeder earthing 3. Rack-in / rack-out operation of Switching device truck. 4. Not- Emergency manual charging of VCB operating mechanism.

37 Saves Lives: How? Front door interlocks 1. Racking of VCB truck from Test to Service position not possible until the front door is closed and locked. 2. Front door cannot be closed and locked until the LV control plug is securely connected. 3. Front door cannot be opened until the VCB is switched OFF and racked out in Test position.

38 Saves Lives: How? Partition class: PM 1. Earthed metallic shutters and partitions ensure partition class PM. 2. Class PM ensures no electric field in the opened compartment and no electrical field change in the adjacent compartments. 3. Thus partition class PM ensures safe maintenance when the switching device chamber is opened while keeping the busbars as well as cables under charged conditions.

39 Saves Lives: How? What is an internal arc? It is a high resistance arc fault within the switchgear enclosure due to insulation failure. What are the effects of an internal arc fault? The fault current passing through the electric arc increases the air temperature inside the faulty compartment. The hot air expands and exerts very high pressure on the compartment walls and doors. If the switchgear is not designed and qualified for an internal arc, the high pressure can rupture the enclosure and endangers the life of persons working near the switchgear.

40 This is what will happen if the switchgear
Saves Lives: How? This is what will happen if the switchgear is not designed and qualified for internal arc. start Internal Arc Test.mpg Film Imagine what will happen to your operator.

41 Saves Lives: How? What happens when there is an arc fault in an Internal Arc Classified switchgear as per IEC Correctly secured door and covers do not open. No fragmentation of the enclosure occurs within the time specified for the test. Arcing doesn’t cause holes in the accessible sides up to a height of 2 m. Cotton test indicators do not ignite due to the effect of hot gases. The enclosure remains connected to its earthing point.

42 If this failure happened in your SIMOPRIME, no one would even be hurt.
Saves Lives: How? If this failure happened in your SIMOPRIME, no one would even be hurt.

43 Vacuum Circuit Breaker means no explosion is possible.
Saves Lives: How? Vacuum Circuit Breaker means no explosion is possible.

44 vacuum circuit breaker.mpg
Saves Lives: How? SF6 CB SIEMENS CB start SF6 circuit breaker.mpg Film start vacuum circuit breaker.mpg Film Which interrupter would you prefer?

45 Saves Lives: How? Arc medium free from toxic by-products 2. Environment friendly and compatible

46 Make proof earthing switch tested inside the panel.
Saves Lives: How? Make proof earthing switch tested inside the panel.

47 Saves Lives: Summary Benefit Features 2. Saves Lives 2.1 All operations behind closed front door 2.2 Front door interlocks with VCB 2.3 Partition class PM 2.4 Internal Arc Classification switchgear

48 Saves Lives: Summary Benefit Features 2. Saves Lives 2.5 Make proof earthing switch 2.6 Use of vacuum switching technology

49 Increases Productivity
SIMOPRIME: Benefit No. 3 Increases Productivity

50 Increases Productivity: How?
Metallic and earthed shutters and partitions Safe to touch Loss of Service Continuity category LSC2B-PM Maintenance in switching device compartment possible without de-energising the corresponding cable connections and busbars.

51 Increases Productivity: How?
Use of maintenance free Siemens vacuum interrupters means no interruption in power supply. Interrupters MTBF: 38,500 Years

52 Increases Productivity: How?
Use of maintenance-free Siemens Vacuum Circuit Breaker means no interruption in power supply. VCB MTBF: 6300 Years

53 Increases Productivity: Summary
Benefit Features 3. Increases Productivity 3.1 LSC2B-PM Switchgear 3.2 Use of vacuum switching technology

54 SIMOPRIME: Benefit No. 4 Saves Money

55 Use of maintenance-free Siemens Vacuum Circuit Breaker
Saves Money: How? Use of maintenance-free Siemens Vacuum Circuit Breaker on withdrawable truck means low maintenance costs.

56 Use of maintenance-free Siemens Vacuum Circuit Breaker
Saves Money: How? Use of maintenance-free Siemens Vacuum Circuit Breaker means less life cycle cost.

57 Easy access to busbars via
Saves Money: How? Easy access to busbars via rear or top means short installation time and less installation costs.

58 Switchgear installation, operation and maintenance
Saves Money: How? Switchgear installation, operation and maintenance without any special tools and tackles means low life cycle cost.

59 Saves Money: Summary Benefit Features 4. Saves Money 4.1 Less maintenance cost 4.2 Less installation cost 4.3 Less life cycle cost

60 SIMOPRIME: Benefits´ summary
1. Peace of Mind 2. Saves Lives 3. Increases Productivity 4. Saves Money

61 The new air-insulated, metal-enclosed, metal-clad
SIMOPRIME The new air-insulated, metal-enclosed, metal-clad medium voltage switchgear from SIEMENS


Download ppt "Switchgear for Primary Distribution"

Similar presentations


Ads by Google