Training.

Slides:



Advertisements
Similar presentations
Configuring APACS & AAN Controllers
Advertisements

SK-ACP Installation Overview
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
Deigning a System.
EMerge Browser Managed Security Platform Module 2 Hardware install.
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.

January 2005 An Introduction to Entro 5 The Access Security Group.
SAC844 Anviz Online Training Lesson 8
N-TEC Access Control Connecting For Growth.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
hotEx RADIUS Manager Installation
PPT Networks, Network operating systems. PPT Networking - Basics Network defined Network defined The difference between Standalone and networked.
GigE Knowledge. BODE, Company Profile Page: 2 Table of contents  GigE Benefits  Network Card and Jumbo Frames  Camera - IP address obtainment  Multi.
INTRUSION ALARM TECHNOLOGY
G4 Control and Management Solution for Data- Centers and Computer Rooms.
ET3100 BioFlex TimeClock. What is fingerprint scanning?  It is a pattern acquisition and recognition established on a person’s.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Chapter 20 Networks. 4 Questions that need to be answered concerning networks? –How will each computer be identified? –What kind of wire should you run.
January 2005 Bewator Entro 5 An introduction.
ActEyes IP Cam Training Part 1: Camera Setup. Network Setup Overview Each IP Cam on the network will need its own IP address to be assigned. This address.
Viola Systems M2M solution installation
V-Series Panel Hardware, Installation & maintenance.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Cisco Threaded Case Study
ACCESS CONTROL ExpansE - Distributed Access Control.
EMerge Browser Managed Security Platform Module 3: Startup eMerge Certification Course  Physical connection  TCP/IP Characteristics of PC  Initial connection.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Lets play Jeopardy No, sorry. You got it! Devices CommunicConnectors Net Address Components
Case Study Computer Controlled Radiation Monitoring System
Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access
Summary - Part 2 - Objectives The purpose of this basic IP technology training is to explain video over IP network. This training describes how video can.
Integra32 System - Training Course
McGraw-Hill©The McGraw-Hill Companies, Inc., 2004 Connecting Devices CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY, BHOPAL Department of Electronics and.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014.
Hardware Introduction – Standard vs Q.i
Copyright © 2008 FingerTec Worldwide Limited. All rights reserved
Ethernet I/O Set-Up This presentation will step through a typical configuration of the CON-DVT-IOE. Intellect 1.5 is used for the software portion. NEXT.
New product introduction:
PIM Technical Training, December 2011 Brian Whitcomb 12/20/2011 Call-in Number = Pass code =
Run the on your PC to start the firmware configuration process Run IP Config Tool.
Draft UniNet-ID Sales Training For ESD Sales People & Estimators.
Team Members: ECE- Wes Williams, Will Steiden, Josh Howard, Alan Jimenez Sponsor: Brad Luyster Honeywell Network Traffic Generator.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
VAX Updates Vicon Access Control
Industrial 1-Port 802.3at PoE+ to 2-Port 802.3af PoE Extender
Hearty Welcome!.
CMV-NET Chigo VRF Network Centralized Control System
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
Industrial communication networks
COSEC ARC IP based Access Control Panel.
Hardware, Installation & maintenance
2N® Access Unit Touch Keypad
Connections Topology of Apollo ACS.
Basics of Communications
High Security and Access Systems
IP-AK2 Access Control Solution
Networking | Hardware Components
Field installable, upgradeable and scaleable
Presentation transcript:

Training

Terminology Port- The connection to the server or pc. On sateon pro this is always ip field network-a group of controllers connected to port usually on 485 line header- an Ethernet/485 converter unit that allows a line of 485 controllers to be connected to a pc Enclosure- a power supply unit that allows up to two controllers or one controller and one ip board to be mounted in it.

Sateon Pro Controllers System Setup Part 1 - Hardware Cable Types Data Comms 485 Data Comms Ethernet Data Comms Sateon Pro Controllers 485 Ethernet Sateon Pro Enclosures

Line Header to Panel (Comms Converter) Cable Types Line Header to Panel (Comms Converter) 2 Pair Belden (or equivalent) #8723 1200m per Segment Cat 5 – Use Twists – Not for electrically noisy environments – 200m Panel to Reader See Reader Documentation 50m (if using Keypad Interface) External Inputs 2 Core Cable (Alarm) 100m Locks Use suitable gauge cable for current draw and volt drop Current Draw (Amps) x Distance (Meters) x Wire Resistance per Meter (Ohms) = Voltage Drop (Volts)

Data Comms 485 Data Comms SATEON PRO MINI PC Ethernet Door Controllers

485 Panels

10 Panels on a line maximum Max 1200m No T taps / loops Sateon Pro 485 RS-485 Two wire (plus Ground) – 1 Pair 10 Panels on a line maximum Max 1200m No T taps / loops Each pair should be twisted All controllers will need an Ethernet Line Header

Ethernet Line Header Sateon Pro Line Header Can be mounted in standard Enclosure

Data Line Overview 485 Panels are Polled 1 2 3 4 ….. 10 Addresses do NOT have to be sequential PORT connects a SATEON Comms Engine to Panels SEGMENT - 1,200m length of Belden (2 or 4 wire) Field Network - Cable from LINE HEADER to last Panel 10 Panels - address range 1 to 63

Ethernet Panels

Sateon Pro Ethernet Panels are Polled and will immediately Synchronise with SATEON Each IP Panel has it’s own IP address and connects directly to the network via a RJ45 Plug

Panel decides to unlock the door (or not) PRO485 vs PRO ETHERNET PRO 485 (Card Access) Present Card Panel decides to unlock the door (or not) Waits for next Poll from SATEON PRO Tells SATEON PRO about the card and access was allowed PRO ETHERNET (Card Access) Present Card Panel decides to unlock the door (or not) Tells SATEON about the card and access was allowed 485 (Input to Output on another Panel) Activate input on Panel 1 Panel 1 waits for next Poll from SATEON PRO Panel 1 tells SATEON PRO about the input activation SATEON PRO broadcasts to Panel 2 to activate the output PRO ETH (Input to Output on another Panel) Activate input on Panel 1 Panel 1 tells SATEON about the input activation SATEON broadcasts to Panel 2 to activate the output

Request To Exit contact must be N/O Sateon Pro Panel Break Glass Monitoring Request To Exit contact must be N/O Break Glass Unit contact must be N/O

Sateon Pro Summary Intelligent Door Controller 485 TCP/IP 2 doors read in. 1 door read in/out Additional alarm input Card capacity 500 users Real-time processing at door LED and sounder outputs Memory buffer whilst off-line (4,000 Events) Upgrade flash whilst system is working Volt Free Changeover output for Locks Can be mounted in any PSU

Sateon Pro Controller Connections

Sateon Pro Lock Connections

Sateon Pro Reader Wiring

Sateon Pro Door Monitor Wiring Door Sensor – Normally closed Door Sensor – Normally closed - Monitored Dual Door Sensor – Normally closed - Monitored

Request To Exit contact must be N/O Sateon Pro Break Glass Monitoring Request To Exit contact must be N/O Break Glass Unit contact must be N/O

Sateon Pro Input Wiring Input – Normally closed or Normally Open Input – Normally closed or Normally Open

AES Encryption on eSeries Real-time processing Sateon Pro Input / Output IO RS485 TCP/IP AES Encryption on eSeries Real-time processing Memory buffer whilst off-line (4,000 Events) Upgrade flash whilst system is working 8in / 4out Can be mounted in any Enclosure

Sateon Pro Input / Output 485 & Ethernet

EZ Enclosures

Sateon Pro Mains Enclosure 2 x Sat Pro board or 1 x Sat Pro board and 1x IO board 1 x 7Ah Battery Built in tamper to lid Built in power supply (3A) with 2A available for external equipment, i.e. locks and readers

Sateon Pro Mains Enclosure

Sateon Pro POE+ Enclosure 2 x Sat Pro Panel or 1 x Sat Pro Panel & 1x IO board 1 x 7Ah Battery Built in tamper to lid Built in power supply with 2A available for external equipment, i.e. locks and readers POE 802.3af 44VDC 350mA 15.4W 900mA POE+ 802.3at 44VDC 1700mA 25.5W 2000mA

EZ POE Enclosure

IP Panel IP Panel IP Panel Sateon Pro Hardware Overview Up to 10 x RS485 Panels

Q&A Were you listening??? Question 1 - How long can a segment of the Comms line be? Question 2 - What is the value of the EOL resistor that should be fitted to the beginning and end of the Comms line. Question 3 - How many cards does the Sateon Pro board hold? Question 4 – How many controllers does it support? Question 5 - Can you wire a Sateon Pro485 board to a Sateon Pro IP? Question 6 - How many Sateon Pro boards fit in an Enclosure? Question 7 - What is the max Amps available for locking in an Enclosure?

Add a eSeries (IP) Panel Update the Firmware in a Panel Add a Door System Setup Part 1 - Software Install SATEON PRO Licence SATEON PRO Add a 485 Panel (I/O Board) Add an Input Add a eSeries (IP) Panel Update the Firmware in a Panel Add a Door Add a Reader Add a Person Add Access Add a Token Unlock a door

Must change password on first logon Can change to sateon if you wish SATEON - LOGON Username : admin Password : sateon Must change password on first logon Can change to sateon if you wish

SATEON Main Screen

Visitors not included on Sateon Pro SATEON Hubs Access Control Control Centre Reports Event Configuration System Configuration Visitors not included on Sateon Pro

Apply the licence Verify the licence Setup the Token Type SATEON – Initial Tasks Apply the licence Verify the licence Setup the Token Type Setup the Site Name Setup the Comms Engine

Access Control – Token Management – Token Types - Add SATEON – Create the Token Access Control – Token Management – Token Types - Add

Access Control – Device Management - Site – Main Site SATEON – Create the Site Access Control – Device Management - Site – Main Site

SATEON Create the Comms engine Access Control – Device Management - Comms Engine – Add

Will assign an address in 169.254.?.? Range if no DHCP available. SATEON Programming Pro Devices IP Panel or Line Header. When supplied are DHCP. Will assign an address in 169.254.?.? Range if no DHCP available. Use the eSeriesDeviceProgrammer tool to set the IP address. Encrypted devices will not come on line until ‘seeded’ using the eSeriesDeviceProgrammer tool with access to a valid SATEON licence. eSeriesDeviceProgrammer will find devices in the same subnet and allow you to program them. eSeriesDeviceProgrammer can be run from (and set the encryption of an Ethernet device) from any SATEON client machine (Config required)

SATEON EseriesDeviceProgrammer.exe

SATEON

A 485 Panel wires to a Field Network SATEON A 485 Panel wires to a Field Network Each field network has at least one Port, the Port is the physical connection between the LAN / WAN and the Field Network. A Field Network may have many Ports. A Field Network may have 10 Panels. Access Control – Device Management – Field Network– Add Access Control – Device Management - Port– Add Access Control – Device Management - Panel– Add

SATEON

SATEON

SATEON

Access Control – Access Management – Access Groups SATEON Access Control – Access Management – Access Groups

SATEON Time schedules are used to define the periods during which things can happen within the SATEON access control system. For example; When access is permitted at certain doors When events are reported When actions can occur. A time schedule is set up as a combination of time patterns, where each time pattern defines one or more periods of time. Each individual period of time with a defined start and end time is an appointment. Appointments can consist of an entire day.

Update the Firmware in a Panel Add a Door Add a Reader Add a Person Recap Install SATEON PRO Licence SATEON PRO Add a 485 Panel Add a PRO(IP) Panel Update the Firmware in a Panel Add a Door Add a Reader Add a Person Add Access Add a Token Unlock a door