High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.

Slides:



Advertisements
Similar presentations
Low Rise Multi-Family UES Measure (NWESH) Measure Proposal Presentation to the Regional Technical Forum Sept. 19 th, 2012 Spec Development and Analysis.
Advertisements

Advanced Heat Pump Water Heater Research Conducted by WSU Energy Program Funded by Bonneville Power Administration BPA Technology Innovation Project #292.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Northwest ENERGY STAR Specification for Oregon 2012 Active UES Proposal Presentation to the Regional Technical Forum November 1, 2011 Ben Larson, Ecotope.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Model Conservation Standards and Surcharge Recommendation Economic Analysis for for New Single Family Home Construction April 17, 2009.
Impact of Incentives: Driving Demand for Efficient Products Steven Nadel ACEEE.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
HPWH UES Measure Initial Review 16 April Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Presentation, Discussion, and Decision on Deemed Measures for EnergyStar Homes: Zonal Electric Heat Path (BOP2) for ID and MT Ductless Heat Pump Technical.
Northwest Power and Conservation Council Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction June.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
Ben Larson 28 September th Avenue NE, Seattle, WA (206) Fax: (206)
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.
Northwest Power Planning Council The Fifth Plan’s Draft Conservation Resource Assessment Summary of Results To Date April 8, 2003.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Washington Residential Energy Code 2012: Overview 17 December 2013 Ben Larson, Ecotope 1.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
Predicted Savings for NW Energy Star for Homes and WA BuiltGreen Homes Specification Update Single Family New Construction Regional Technical Forum August.
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction May 5, 2009.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
Regional Technical Forum Future Funding Discussion March 19, 2014 RTF PAC Presentation.
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Research Strategy: New-Construction Manufactured Home Measures Research and Evaluation Subcommittee Josh Rushton November 19, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Road-Mapping Session BPA Energy Efficiency.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
High Performance Manufactured Homes UES Measures Sunset Date Extension Request Regional Technical Forum December 16 th, 2014.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Manufactured Homes Check-in Christopher Dymond March 14, 2014.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Northwest Power and Conservation Council Slide 1 Heat Pump Water Heaters Tom Eckman Manager, Conservation Resources Northwest Power and Conservation Council.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Heat Pump Water Heaters: Interior, Ducted Installations Presentation to the Regional Technical Forum December 13, 2011 Ben Larson, Ecotope
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Home Energy Savings Program Wyoming
Presentation transcript:

High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration Presentation by: Ben Larson, Ecotope and Tom Hewes, Northwest Energy Works

Measure Summary Measure name: High Performance Manufactured Homes (HPMH) Measure sponsor: Bonneville Power Administration Measure description: – Construction of and installation of lighting and appliances in new, manufactured homes in accordance with the High Performance Manufactured Home Specification Measure type: UES Requesting Status: Approved Change in measure status: Yes (proposed  active) Change in measure savings: No Change in measure cost effectiveness: No Other or follow-on work for RTF: No 2

Background: NEEM Program (Northwest Energy Efficient Manufactured Home) Built on a 25 year history of partnership with regional utilities Support the promotion of energy efficient manufactured homes NEEM is a joint energy efficiency program between the regions utilities and the regional manufactured home industry – The region’s 10 HUD (Manufactured home) and Modular (factory-built to local code) prefab builders build to NEEM specs – NEEM is supported by 74+ utilities in the PNW and California – NEEM has a set of factory quality management procedures and inspections – Northwest Energy Works (NEW), NEEM central administrator

Problem Statements: Motivating a new Program 4 NW has been focused on manufactured housing market for over two-decades Over 155,000 or 68% of all new manufactured homes built since 1989 have constructed to high efficiency standards Despite a $1000 per home corporate tax credit for Energy Star, little market transformation has occurred outside PNW Market transformation progress in the PNW is sliding due to market pressure from outside the region

The HPMH Project HPMH development funded by Bonneville Power Administration – Goals of the project are to get deep energy savings in this housing sector – Program to be integrated into the existing NEEM infrastructure Proposed Approach – Develop a specification to address all aspects of home energy use – Provide a forum for regional equipment initiatives – Develop a new market for manufactured homes – Provide large, cost-effective, electric savings 5

Baseline in the Absence of NEEM 6 NEEM participation dropped significantly at the end of MAP, and Energy Star participation elsewhere in the country has rather minimal market share in the absence of incentives. Therefore, the baseline is likely to contain no EnergyStar houses and only contain current market (non-NEEM) standard practice

Uo Baseline Specifications Uo is the coefficient of heat transmission for the entire structure – (Btu/hr-ft 2 -°F) – Conductivity per square foot of building envelope – Not including infiltration and ventilation “HUD+” is the current NW baseline based on current market research by WSU and NEW 7 Northwest Specific Uo Values TypeCommentsUo HUD Federal Maximum0.079 “HUD+” Northwest Baseline0.065 NEEM Northwest Energy Efficient Manufactured Home0.054 HPMH High Performance Manufactured Home (Super NEEM)0.040

Manufactured Homes Specifications Overview ComponentUnits Baseline "HUD+" NEEM HPMH "Super NEEM" Envelope CeilingR-ValueR22R38R45 WallR-ValueR11 -- R21R21 R21 + R5 Foam Sheathing Window U-ValueU-Value Glazing % of CFA12% DoorU-Value0.2 FloorR-ValueR19R33R38 InfiltrationACH VentilationExhaust FanMarket BaseEnergyStar UoBtu/hr-ft 2 -°F HVAC Heating System Electric FAF DHP HSPF 10 & Wall Heaters Cooling System none DHP SEER 20 Supply Duct Leakage% system flow12.5%5%No Ducts Return Duct Leakage% system flowNone - Interior No Ducts DHW Water HeaterEF0.9 EF0.93 EFHPWH Shower Headgpm Lighting LPDW/ft Appliances Dishwasher Market Base EnergyStar Refrigerator Market Base EnergyStar 8

UES Analysis Summary Refer to Measure Workbook

Analysis Approach (1) Lighting calculated with LPD method Appliance savings from existing RTF measures Calibrated SEEM runs for estimating – heating, cooling, ventilation, and DHW DHW energy use – Parallel analysis to HPWH presented in 2011

Analysis Approach (2) Heating, cooling, ventilation, and DHW energy use calculated with SEEM – DHP Modeling methodology from NEEA Ductless Heat Pump Impact & Process Evaluation: Field Metering Report Field findings: DHP heats differing house fraction based on climate – HZ1: 74%, HZ2: 63%, HZ3: 45% Calibrated SEEM to pre/post DHP installation periods at 91 houses – Unique simulations created for each house based on detailed audits – Note: energy uses here not reflective of DHP program savings – they are only applicable here as a calibration exercise – HPWH Modeling based on SEEM simulated annual crawl space temperature profile and HPWH COP map HPWH installed in sound-attenuated, buffered closet which draws air from crawl space and exhausts outdoors 11 Method Heating Energy Use (kWh/yr) N MeanSD Pre-Installation Billing Data Pre-Installation SEEM 66.8°F Setpoint Post-Installation Metered Data Post-Installation SEEM 69.5°F Setpoint

Measure Cost, Life, and Sunset Criteria 12 Total Package Cost 2006 $s: $9,205 – See workbook “CostSummary” & “CostData” tabs Measure Life:~36-39 years – Shell: 45 years – DHP:20 years – Ventilation Fan: 20 years – DHW: 15 years – Lights: 7.6 years – Appliances: 16 years Sunset Criteria: – Measure shall sunset at the end of 2013, at which time the lighting savings UES component of the measure shall be reevaluated against the changing federal lighting standards.

13

Results

15

Energy Use, Savings, and B/C Ratio 16 ClimatesTotal Annual Energy Use (kWh/yr)Savings (kWh/yr) (yrs) HeatingCooling Baseline "HUD+" NEEM HPMH "Super NEEM" HPMH to Baseline B/C Ratio Measure Life HZ1CZ115,83612,9577,6688, HZ1CZ215,83612,9577,7718, HZ1CZ315,83612,9577,9357, HZ2CZ119,59715,5679,23910, HZ2CZ219,59715,5679,33610, HZ2CZ319,59715,5679,49510, HZ3CZ122,55817,57011,14711, HZ3CZ222,55817,57011,23511, HZ3CZ322,55817,57011,38011,

17

Energy Use by Load Significant reductions in space heating, water heating, and lighting over both “HUD+” baseline and NEEM. – Big savings from wall sheathing, triple-glazed windows, DHPs, HPWH, and lighting improvements 18

19

Motion for Approval “I _________ move that the RTF approve the UES for High Performance Manufactured Homes with active status which will sunset at the end of 2013.” 20

Contacts Northwest Energy Works Tom Hewes x101 Brady Peaks x Bonneville Power Administration Mark Johnson Ecotope Ben Larson x207