CBR Suit Training Disaster Preparedness and Management Unit.

Slides:



Advertisements
Similar presentations
Personal Protective Equipment (PPE)
Advertisements

Personal Protective Equipment
EMERGENCY MEDICAL MANAGEMENT OF RADIATION CAUSALTIES IN HOSPITAL Module XVII.
Randy Wax, MD, FRCPC (Critical Care)
CBRNE Training Academy
CBR-D PPE Mask and Suit.
HAZMAT for ED Staff 2012.
Decontamination at a suspected radiological incident.
Personal Protective Equipment (PPE)
SWEDISH EMERGENCY DISASTER EQUIPMENT PREPARATION & DONNING PPE.
Assisting Another Sterile Team Member
Respirator Awareness Training CFR
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Powered Air Purifying Respirator (PAPR) Infection Control Unit.
PPE Use in Healthcare Settings: How to Safely Don, Use, and Remove PPE
Optimum Round Pool Instructions. Prepare the pool site Remove all the grass on a surface 2’ wider than the size of the pool Level the ground.
2 Fire Fighter Qualifications and Safety Skill Drills.
TESTING Dräger PSS 7000 Breathing Apparatus GENERAL TEST
Blackwood Fire Company IN-HOUSE SCBA REQUALIFICATION.
Personal Protective Equipment For Ambulance Crews Adapted from Liberia DOH presentations P Bunge, MD October 2014.
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
Radiation Protection Technology Respiratory Protection Air Sampling Radiological Safety and Response RPT-243-PE-6.
Supplied-air hood Copyright © 2013 by The S.E.A. Group.
31 Hazardous Materials: Personal Protective Equipment, Scene Safety, and Scene Control.
NBC CTT Tasks Presented by:. NBC CTT Tasks Presented by:
Governor’s Secure Commonwealth Initiative, Health and Human Resources Sub-Panel Meeting Janis Ober MSN RN CIC Director, Infection Prevention.
Presented by: Sana’a AL-Sulami Teacher assistant Nursing department.
Doffing PPE (with PAPR) 12/23/ Requires that the trained observer be donned in level 1 PPE *This associate will read aloud each step of the doffing.
Lone “Undresser” Infection Prevention & Control Team.
Bullard PA20 Powered Air Purifying Respirator (PAPR) Training Material
Donning PPE (with N95) Level The emerging EBOLA preparedness is new for our nation and our organizations. Information changes rapidly, sometimes.
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
Donning PPE (with PAPR) Level The emerging EBOLA preparedness is new for our nation and our organizations. Information changes rapidly, sometimes.
Personal Protective Equipment
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
Personal Protective Equipment
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Removal of PPE – Contaminated Staff Infection Prevention & Control Team.
Respiratory Safety Public Safety Murray State University.
Irene Fernando RN CNOR PCC/OR EDUCATOR Janice Kay RN.
Personal Protective Equipment (PPE). FACTORS AFFECTING CHEMICAL RESISTANCE 1.Length of exposure time thin materials for one application –disposable.
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Doffing PPE (with N95 respirator)
PUBLIC SAFETY INSTRUCTIONS
Training structure EFFO Ebola Safety and good quality work
SKID STEER SAFETY. SKID STEERS Pre-operation checklist Maintenance Safe operation Entering and exiting safely.
Chapter 32 ASEPTIC TECHNIQUE AND WOUND MANAGEMENT Pauline Cardwell.
Protect Yourself From Chemical/Biological Contamination Using Your Assigned Protective Mask.
CBR Radio Training Disaster Preparedness and Management Unit (Version 2.2; 13 April 2015)
Safety in Tactical Situations. Injured – Getting Out of the Line of Fire Injured – Getting Out of the Line of Fire You’ve Just Been Shot. You’ve Just.
Procedure for Operating Leaf Blowers (Revision 1 – 17th November 2010) Toolbox Talk.
Copyright © 2016 by The S.E.A. Group
Respiratory Protection Training
PPE Donning and Doffing
Chemical Protection.
Donning with PAPR No personal items in room; e.g. jewelry, cell phone
Donning with N95 No personal items in room; e.g. jewelry, cell phone
2. Engage trained observer 3. Disinfect outer gloves
Infection Prevention & Control Team
CBRN Overview SGT Hubbard, Bobbie Lee | 2015.
PPE Donning and Doffing
Laboratory Techniques Supporting Infectious Disease Surveillance and Epidemiology Personal Protective Equipment Demonstration Erin Swaney October 20,
Removal of PPE – Contaminated Staff
Aseptic Awareness in the Operating Room
Presentation transcript:

CBR Suit Training Disaster Preparedness and Management Unit

Background Depending on incident location casualties will begin to arrive at hospitals within 30 minutes of impact. Most casualties arrive at the hospital within 1 to 1.5 hours of the first patient. Masks are the conventional respiratory protection system used by ED staff. They rely on the lungs drawing air through the filter, negative pressure, thus extremely fatiguing. The close fitting mask also reduces communication. Their use requires constant practice. Additionally facial hair and glasses prevent the correct sealing of respiratory masks to the face.

Background Hospitals are critical infrastructure and must be protected from contamination in order the maintain the capacity to treat patients and to protect staff. Patients delivered to a hospital by ST John Ambulance (SJA) from the site of a CBR incident will have been decontaminated at the incident site. Those that self present will include contaminated and the worried well.

Background Self presenters cannot be permitted to enter a hospital until they have been decontaminated. Hospitals must have the capacity to safely decontaminate all self presenters. The protective dress to be worn by Hospital staff conducting decontamination of self presented is the LED 500 CBR.

Objective To safely operate the supplied CBR suit

Before you get started Change into scrubs Drink some water Know your designated role in the decontamination team Go to the toilet Have your vital signs taken by the Safety Officer

Hazards of operating in CBR suit Reduced sensory input Work performance impacts Physical effects on operator Communication Psychological factors

Reduced sensory input Touch Reduced sensitivity Reduced manual dexterity Mobility Impaired balance, reaction time and agility

Physical effects to operator Body temperature and heart rate may increase Endurance times are reduced Warning signs will include Changes in gait (staggering) Changes in speech (slurring) Changes in behaviour (erratic) Many of these are difficult to monitor in CBR suit – this makes observation by buddy, communications and use of a safety officer essential.

Your equipment In the bag Suit with camatril gloves attached Butyl outer gloves (optional) Blower – Gait C420 Belt assembly 2 filter cartridges Air pipe Contents list

Your equipment Bag presentation (closed)

Your equipment Bag presentation (open)

Your equipment External Lithium battery Boots Radio

GAIT Positive Air Pressure Blower

Lithium battery Minimum 8 hours endurance Do not break or burn

Rechargeable battery Minimum 8 hours use Recharge time varies Should be used for training only

Filters TrainingOperations

C420 PARP Blower Fan speed control Pipe intake Filter ports Battery Compartment

Donning of CBR suit Always use a buddy! Remove jewellery that might puncture the suit!

Step 1: Prepare blower Belt through top loops Attach Belt to the PAPR

Step 1: Prepare blower Ensure belt has buckle facing out

Remove the covers from the PAPR and the filters (place plastic covers from blower in bag)

Attach the filters to the PAPR

Then remove any remaining plastic covers (place plastic covers in bag)

Unscrew the battery compartment and insert battery

Step 2: Don suit Lay suit out flat and inspect for damage (both sides)

Open zip

Check glove size - change if necessary To change gloves: Turn sleeve inside out O ring

Changing gloves Remove rubber O ring Remove glove.

Changing gloves (cont) Ensure suit material covers plastic cuff with a 5 mm overhang Place new glove on (remember to check glove is orientated correctly onto sleeve) Plastic cuff covered by suit material

Changing gloves (cont) Ensure glove overhangs plastic cuff by approx 5 mm. Place on O ring (over glove onto first indentation then roll onto middle indentation). Pull glove back through sleeve.

Feed the blower pipe through the pocket on the back of the suit. Attach pipe to the rear of the suit at back of head. Ensure O ring is in

Attach pipe to blower

Turn on to highest setting: ensure air is being blown into suit.

Put your right leg into suit first then left leg (Buddy to hold blower)

Put on boots Ensure the outer covering sleeve is rolled back

Roll down outer covering sleeve

Head into hood first. If air is missing and you begin to fog do not proceed

Then arms into the suit and adjust gloves.

Buddy to do up zip. Raise right arm to allow zip to go all the way to top. Then close velcro

Buddy to secure PAPR around your waist. PAPR to sit on left hip.

You are now ready to go!

Step 3: Doffing Always decontaminate first (use showers) Operator hold PAPR steady whilst buddy undoes belt Buddy unzips suits (do not turn off or disconnect blower) Buddy holds blower steady Operator removes arms from the sleeves and then lift hood off Blower may now be turned off Sit down, place blower on table or on seat, remove boots Pull on toes end to remove suit legs

Doffing Step out of suit Hand radio to supervisor, recharge batteries Replace plastic caps on blower and hose pipe, ensure the O ring is in the end of the hose pipe

Cleaning Wipe the inside and outside of the suit with a damp cloth Do not use detergents Hang to dry naturally Inspect suit for damage

Step 4: Packing of suit Remove battery from blower, hand to supervisor Remove operational filters, hand to supervisor or remove training filters and place in bag Place blower, pipe, butyl gloves (if not used) and belt in bag Blower to be places in mesh pocket bag

Step 4: Packing of suit Place suit down on a soft surface Pull up top suit and push in material that is behind the head to form a cavity

Fold arms to back of suit. Side of suit not to wider than width of visor

Fold legs up over arms

Fold up to base of hood (two folds required)

Fold into back of visor Pack into bag with visor facing up