Power Sensors Ltd – www.PowerSensorsLtd.com Introducing PQube 3 Power Sensors Ltd – www.PowerSensorsLtd.com.

Slides:



Advertisements
Similar presentations
EMS ROMC Environment monitoring system for ROMC..
Advertisements

RC & M Remote Control and Management System System of remote control and monitoring of telecommunication network sites RC & M Remote Control and Management.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Multi Functional Digital Fault Recorder
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
IO Controller Module Arbitrates IO from the CCP Physically separable from CCP –Can be used as independent data logger or used in future projects. Implemented.
Elliot Buller Luke Ciavonne Mehdi Mehrpartou Advisor: Dr. Steven Reising.
Isolated high speed 8 channel multi function logger midi LOGGER GL900 Product introduction midi LOGGER GL900 Product introduction The data logger that.
1 SD Recorder OS-TM-V701A for Driving Security Surveillance.
G650 Generator Protection & Control System
Looking for a more powerful circuit monitor?
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Jan. 1, PM7000 John Outram Outram Research Ltd Exclusive in Ohio By:
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Portable Working Standard and Power Quality Analyzer
CCHRC Seminar Alan Mitchell Analysis North May 6, 2014.
 Controllers  RCX  Wall mount  Panel mount  Controller with data logger  SMX  Wall mount  Panel mount  Data loggers  DUE  Wall mount  Panel.
Digital Signal Processing and Generation for a DC Current Transformer for Particle Accelerators Silvia Zorzetti.
Trimble NetR8 GNSS Reference Receiver
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Path The purpose of this project is to design a universal data recording device to monitor the health of a Dresser-Rand compressor during operation. In.
Alex Wanamaker.  2 astable 555 timer circuits  Blinking rate: ~1.1 seconds  Q1 and Q2 used to provide additional current for the circuit beyond.
ControlLogix 5580 Controllers
Low Power Management for CC2430 Jinho Son Real-Time System Lab.
DL750P On Sale Now 1 DL750P Promotional Material.
Advanced Datalogger: Z-GPRS3. # 4 Digital Input PNP, NPN bit max 30 Hz) RAM and Flash RAM 256 KB 1 MB + 8 MB (log) SD card max 32 GB.
FlashBack-4 Development
HighPROTEC-2 MRMV4-2 Motor protection relay with voltage measurement Sales presentation 2015/08/10.
2016 Maintenance Innovation Challenge
Poseidon 4002 Rack monitoring.
Intellectual Insulation Indicator «3i»
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
ControlLogix 5580 Controller
micro-FlashBack-4 4 Channel SD or 1 x HD Miniature DVR
PMC-680i web interface Sep.9th 2016.
IP-based 8-port Switched Power Manager
RF acceleration and transverse damper systems
GammaTRACER Key features
Maintain, Manage And Monitor Outdoor Systems Remotely
Application layer tcp/ip
By Sonia Thakur James M.Conrad Presenter: Bin Huang
H.264 4ch/8ch/16ch Stand Alone DVR
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Programmable Logic Controllers: I/O
SCADA for Remote Industrial Plant
Electronics in the NOVAC-system
Power Monitoring Battle Card
Presenter: Artur M. KUCZAPSKI
EMC Lab presentation.
NI-sbRIO BASED PLATFORM FOR REAL TIME SPECTROSCOPY
To change picture – with LCD view.
Scientific Columbus Family of Meters
PowerFactory Monitor Dynamic System Monitor and Model Verification
ICP DAS Power Monitor and Management Solution 2016,03,28
Vibration Energy Harvesting Circuit to Power Wireless Sensor Nodes
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Sukumara T, Janne S, Kishan SG, Harish G, Eashwar / Presented to CIGRE Colloquium, Mysore, Cyber Security - Secure communication design for.
PQube vs. X (instrument from competitors)
Neurochip3.
DVR LH-Series 1 Key Features H.264 8ch/16ch Stand Alone DVR
Cableless seismograph Atom
Cableless Seismograph Atom for engineering site investigation
New features, more applications with PQube 3 Power Analyzers
Moxa Embedded Solution on IEC 61850
New features, more applications with PQube 3 Power Analyzers
PowerLogic™ offer for the basic metering market
Simple, accurate tenant sub-metering
And other minutia KD7ZWV (Jan)
Presentation transcript:

Power Sensors Ltd – www.PowerSensorsLtd.com Introducing PQube 3 Power Sensors Ltd – www.PowerSensorsLtd.com

PQube® 3 PQube3/PQube comparison 1/4 PQube Classic PQube 3 Power Quality uses IEC 61000-4-30 methods - HF impulse detection – no recording - Power Quality IEC 61000-4-30 Class A Ed3 2kHz-150kHz cond. emissions measurements 4MHz HF impulse detection & recording Rapid voltage Changes (RVC) Energy Metering– Accuracy class : ANSI C12.20 Accuracy Class 0.5 Energy Metering– Accuracy class : IEC 62053-022 Class 0,2s ANSI C12.20 Class 0.2 for the entire chain including CT’s Hardware 4 Voltage channels External Module for Current (4, 5 chan.) 2 analog AC/DC inputs External Ethernet module Embedded UPS with up to 9 mins 8 Current inputs channels embedded 4 analog AC/DC inputs Ethernet embedded, 3 USB ports External UPS with up to 30 mins/3 hours battery autonomy (configurable) Power Sensors Ltd – www.PowerSensorsLtd.com

PQube® 3 PQube3/PQube comparison 2/4 PQube Classic PQube 3 Sampling frequency 128 samples per cycle Sampling frequency - 512 samples per cycle - 1MHz/4MHz High Frequency impulse - 1MHz for 2kHz-150kHz measurements Voltage inputs Accuracy: ±0.2% rdg ±0.2% FS spec Voltage inputs Accuracy: ±0.01% rdg ±0.01% FS typical Current inputs Accuracy (amplitude): ±0.2% rdg ± 0.2% FS spec Excluding external CTs Current inputs Accuracy (amplitude): ±0.05% rdg ±0.05% FS typical Including the whole chain! PQube3 + CT’s Current inputs Accuracy (angle): ±1deg typical Current inputs Accuracy (angle): ±0.07° typical Including the whole chain! PQube3 + CT’s Power Sensors Ltd – www.PowerSensorsLtd.com

PQube® 3 PQube3/PQube comparison 3/4 PQube Classic PQube 3 Environment Probes TH1 Temperature Humidity Environment Probes EnviroSensor ENV2 Temperature Humidity Barometric pressure 3 axis Acceleration (mechanical shocks, seismic disturbances..) Communications External Ethernet module Web server Email server FTP Modbus TCP/IP Communications 3 USB ports for probes and data copy Embedded Ethernet module Web server (HTTP and secure HTTPs) Email server with secure layer SSL FTP and FTP secure (FTPs) Modbus TCP/IP SNMP (polling, v1,v2 and v3 with traps) Simultaneous FTP/ Modbus/HTTP sessions Power Sensors Ltd – www.PowerSensorsLtd.com

PQube® 3 PQube3/PQube comparison 4/4 PQube Classic PQube 3 Clock synchronization SNTP NTP GPS Storage 4 GB SD Card Data extraction locally by removing the SD card (measurements are interrupted) Internal 16GB flash memory Removable 16GB micro SD Card Data can be extracted locally with no measurement interruption Power Sensors Ltd – www.PowerSensorsLtd.com

PQube® 3 Performance improvements PQube classic Modbus : approx. 150 parameters performance impacted upon event generation or trend generation Modbus refresh rate : 1 Hz Simultaneous data download sessions Performance : Modbus : >3000 parameters no impact upon event generation or trend generation Modbus refresh rate: 2-5 Hz Faster event generation Faster daily trend generation (3 Phase PQube w PQDIF generation): indicative values: PQube 3: email received < 10mins after end of day PQube Classic : received 45 mins or more after end of day Power Sensors Ltd – www.PowerSensorsLtd.com