1 RC & M Remote Control and Management System System of remote control and monitoring of telecommunication network sites RC & M Remote Control and Management System System of remote control and monitoring of telecommunication network sites

2 Purpose of RC&M Remote control, management and monitoring of network equipment of RBS (radio base station), BSC (base station controller), MSC (mobile switch center) and other network sites of mobile network operators.

3 Purpose of RC&M Complex provides data collection from different sources, that are used on a site (temperature/humidity sensors, electricity meters, alarm, fire and security sensors, power supplies system, diesel generators, network equipment etc.) and transfer this data to EMS.

4 Purpose of RC&M Complex gives possibility of remote control from operator workplace to network equipment, power supply systems, diesel generator, climate systems, telecom equipment etc. Complex provides organization of video security, alarm on entry to the territory of base station and access control to sites.

5 Main functions of the system Control and monitoring of climate parameters: temperature and humidity Control and monitoring of environment parameters: gas and dust pollution Security and fire alarm, room flooding alarm Creating ad-hoc report Support different protocols of connection

6 Main functions of the system Control, management and monitoring of power supply systems Control, management and monitoring of diesel generators Remote data collection of energy consumption on network sites Automation of data processing for the calculation of consumed electricity

7 Main functions of the system Remote troubleshooting of telecommunication site equipment for instance - BTS, DXX, XDM, MiniLink Remote access from site to a corporate computer network Outdoor and indoor video monitoring Access control to the remote site and to individual rack units

8 Main functions of the system System operability monitoring Fault management (FM) and process tracking SMS and E-mail messages Administration and audit of users Inventory management

9 Components of RC&M Controller PVS LX EMS Client software Protocol software

10 System architecture of complex

11 Sensors and system equipment

12 PVS LX controller Computer: CPU ARM9 544 MHz; DRAM 128 MB; Flash 32 MB Interfaces: 1x LAN, 1x WAN Ethernet 10/100 BaseT (RJ45); 5 Serial RS-232/RS485/С2; 2x USB 2.0; 1x 1-Wire; 16 x 3-level digital inputs; 2x outputs relay contacts Temperature: -20 ℃~ +55 ℃ Supply: 48V or 24V DC or 220V AC Form factor: 1U rack Hardware specifications:

13 Controller PVS-LX OS: Linux Kernel Version: 2.6.27 Network protocols: TCP, UDP, IPv4, SNMP(v1,v2), ICMP, ARP, SSH, DHCP, Telnet, FTP, PPP, DNS, HTTP, HTTPS, SMS, SMTP, SSL Transfer protocols: RS232/RS485/С1, Modbus over TCP/ІР Telecontrol protocol: IEC 60870-5-104 Electrical meter protocol: IEC 61107, IEC 1142, IEC 61334 (DLMS/COSEM) Security data: Secure Real COM, Secure TCP Server, Secure TCP Client and Secure Pair Connection Software specifications and protocols:

14 Components of RC&M Alarm system Electricity accounting system Climate control system Video security system Access control system Fault Management System

15 Components of RC&M Control and management of network equipment Administration of access permissions Creating and editing forms of reports Inventory management of resources Control of power supply and diesel generator

16 RC&M Client software User interface

17 Climate control system Measurement and monitoring of temperature and humidity Charts and diagrams Coolers/heaters autonomous/remote on/off Formation of alarm messages in case of limits exceeding

18 Alarm system Signal discrete inputs monitoring of a fire and security alarm systems, backup power, etc. Alarm messages about event Alarm audit system administration

19 CCTV system Twenty-four-hour simultaneous CCTV of many different points or areas on a single monitor with the ability to track movement in a frame Distributed video monitoring with the ability to view recordings at any time for analysis Video by motion detectors Synchronic tracking of alarm signals

20 Electricity accounting system Automatic data collection of technological and commercial electricity consumption accounting for each accounting point (group) equipment for defined commercial intervals Accumulation, processing and storage of accounting parameters Comparative analysis of electricity consumption of similar sites Control of electric power parameters (current, voltage, cos φ, frequency) at a given polling interval

21 Consumed electricity calculation system Calculation of average consumption, taking into account losses Providing multi-tariff zone accounting of electricity consumption (rates are registered separately for each accounting point) Maintenance of accounting contracts with electricity suppliers Ad-hoc reports (daily, monthly, annual) Control of electricity consumption limits Electricity balance in the estimated group Export data base on Oracle tool

22 Fault management system (FMS) Monitoring of connection to equipment Creating of alarm messages SMS and email notification Easy adaptation to FMS based on SNMP protocols

23 AdministrationAdministration User profile Access permissions Audit

24 Ad-hoc reports Create and save of different type of reports Automatic generation of reports based on system data Print and export reports

25 Inventory management System equipment and connected devices Oracle database Audit of replacement equipment

26 Diagnostics of network equipment operation Remote diagnostics of network equipment condition (switches, controllers, base radio stations, etc.) Adjustment parameter change

27 Management of power supply systems Remote control of parameters Adjustment parameter change Periodic remote testing of rechargeable batteries Diagnostics of power supply system

28 Management of diesel generators Remote start/stop of generator Remote load on/off Control of voltage, current, frequency, battery voltage Control of oil temperature, level and pressure Control of fuel level, condition and running time

29 Air conditioner remote control Control of environmental parameters Remote control and diagnostic Parameters setting Analysis and diagnostic of cooling efficiency

30 Free cooling systems Setting parameters of operation FreeCooler on/off Control of temperature and engine speed Own development

31 9 Franka str. Lviv 79005 Ukraine tel./fax : +38 032 235 8287 www.mikrokod.com.ua 9 Franka str. Lviv 79005 Ukraine tel./fax : +38 032 235 8287 www.mikrokod.com.ua