NICET Fire Alarm Tech Level 1 Practice Test # 2

Slides:



Advertisements
Similar presentations
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Advertisements

Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013.
NFPA 72 - National Fire Alarm Code Chapter 4 - Notification Appliances
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Journeyman Fire Alarm Installers Test
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
High-Rise Hotels New Codes General Fire Safety Information Ted Erb Fire Prevention Officer Bellevue Fire Department April
Fire Marshal & Medical Emergency Training Please Sign In
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
Inspection and Testing of Fire Alarm Systems (ITFAS)
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Calculation Speed Drill # NEC
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
Understanding Fire Sprinkler Systems (c) Nothing in this Act shall be construed to prevent a fire sprinkler contractor licensed under the Fire Sprinkler.
2008 Code Drills (C) Copyright 2008 Ted "Smitty" Smith 1 Smitty’s Speed Drills.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Using existing lifts in existing buildings to evacuate disabled persons Derek Smith Technical Director UK Lift and Escalator Industry Association.
Elevator Fire Service Mode Basic Operations Prepared by: Lt. Rob Fisher – L72C.
Carbon Monoxide Detection: Code and Legislation Updates
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
CITY OF HARARE EMERGENCY SERVICES
Smitty’s Two Minute Drill Grounding
2011 Changes Two Minute Drill
Smitty’s Two Minute Drills
NICET Fire Alarm Tech Level 1 Practice Test
NICET Fire Alarm Tech Level 1 Practice Test # 4
Smitty’s Two Minute Drill Overcurrent Protection
NICET Fire Alarm Tech Level 1 Practice Test # 9
NICET Fire Alarm Tech Level 1 Practice Test # 6
Smitty’s Two Minute Drill Mixed Content -05
Wilson Hall Fire Protection Features
Smitty’s Two Minute Drill #9: Special Occupancies
Fire Door Inspections Qualified Training
NICET Fire Alarm Tech Level 1 Practice Test # 13
Smitty’s Super Speed Drill for Memorization No. 2
Conductors and Cables 2017 NEC
NICET Fire Alarm Tech Level 1 Practice Test # 3
Smitty’s Super Speed Drill for Memorization No
NICET Fire Alarm Tech Level 1 Practice Test # 10
Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
General Requirements of NFPA 101
Smitty’s Two Minute Drill Photovoltaic Systems
Presented by: Tim Knisely
Two Minute Drill Number 29- Conductors and Raceways
Fire Alarm Tech Practice Test # 16 NICET
Smitty’s Super Speed Drill for Memorization No. 2 Resistor Color Codes
2008 Code Drills Health Care Facilities
Two Minute Drill – Residential 3
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Smitty’s Two Minute Drill Services, Feeders, and Branch Circuits 1
Two Minute Drill – Residential 3
Smitty’s Two Minute Drill Varied Number 7
FIRE ALARM DRILL 26 © Ted Smith 2017.
Smitty’s Two Minute Drill General Knowledge
Smitty’s Two Minute Drill The BIG 5 Drill 1
Smitty’s Two Minute Drill General Knowledge 2
Smitty’s Super Speed Drill for Memorization 8 Forms of Waste
Denver Fire Depart. License Fire Alarm Practice Test # 12
NICET Fire Alarm Tech Level 1 First Aid, CPR, AED #2
Presentation transcript:

NICET Fire Alarm Tech Level 1 Practice Test # 2 © Ted Smith 2017

Instructions Be sure to place this presentation in Slide Show Mode if it is not already in that mode before proceeding The purpose of this drill is to help you improve your skill at finding answers to questions using the applicable fire codes and also to help increase your knowledge of the Fire Alarm codes. Each slide will contain a question. The question will remain in the screen for a period of 2 minutes. At the end of the two minutes, a notification will sound and the slide will transition to the next slide which will have the correct answer to the question. After 15 seconds the next question will appear and the process will continue. During the test do not worry about the correct answers when those slide appear. You will be given an opportunity to review the answers with out the time at the end of the test. Click on the slide to start the timer and begin the test

Denver Building Amendments Records of all system installations, inspections, tests and maintenance required shall be maintained on the premises. The name and Denver Fire Department License number of the person(s) performing the work shall be legible on all forms. True False

Answer True 901.6.2

Denver Building Amendments A testing procedure, reviewed by the smoke control system design professional engineer, shall be submitted to the fire department ________ hours in advance of the acceptance tests being performed. A. 24 B. 48 C. 72 D. 96

answer C. 72 hours 909.10.1(1)

Denver building amendments __________ sets of scaled, engineered installation shop drawings shall be submitted for Fire Department review. Documents shall be of sufficient clarity and detail to fully describe the scope of work. Handwritten notes and comments on reproduced drawings are not acceptable. A. 1 B. 2 C. 3 D. 4

answer B. 2 907.1.2

Denver Building Amendments Light fixtures installed in Marijuana Operations Extraction rooms shall be installed in accordance with the NEC as a __________________ location. A. Class I, Div. 1 B. Class I, Div. 2 C. Class II, Div. 1 D. Class II, Div. 2

Answer A. Class I, Div. 1 3903.1.5 and 3903.2.2

Denver Building Amendments Smoking is prohibited where conditions are such as to make smoking a hazard, and in spaces where flammable or combustible materials are stored. True False

answer True IFC 310.2

Denver Building Amendments Installation of cables used for survivability of fire pump circuits shall comply with: A. NEC Article 695 B. UL 2196 C. Listing Requirements D. All of the above

Answer D. All of the above DBA 913.2.2

Denver Building Amendments In a high rise building, automatic smoke detection is required in all interior corridors which serve as a means of egress for Group _____, ______ and _______ occupancies with an occupant load of 10 or more. A. F1, F2 and F3 B. R1, R2 and R3 C. R1, R3 and R4 D. R1, R2 and R4

answer D. R1,R2 and R4 DBA 907.2.13.1(3)

Denver Building Amendment The radio system control channel in a high rise shall exceed -100dBm at 95% or more of the locations measured within each floor plate. Which of the following areas is not required to have 1000% signal coverage at -100 dBm? A. Parking Garage B. Fire Command Center C. Stairwell D. Elevator lobby

Answer A. Parking Garage DBA 907.2.13.2 DBA 510.1.1

END of QUIz. THE TIME WILL STOP NOW END of QUIz. THE TIME WILL STOP NOW. PLEASE CLICK ON THE SLIDE TO CONTINUE WITHOUT THE TIMER AND REVIEW EACH QUESTION.

Denver Building Amendments Records of all system installations, inspections, tests and maintenance required shall be maintained on the premises. The name and Denver Fire Department License number of the person(s) performing the work shall be legible on all forms. True False

Answer True 901.6.2

Denver Building Amendments A testing procedure, reviewed by the smoke control system design professional engineer, shall be submitted to the fire department ________ hours in advance of the acceptance tests being performed. A. 24 B. 48 C. 72 D. 96

answer C. 72 hours 909.10.1(1)

Denver building amendments __________ sets of scaled, engineered installation shop drawings shall be submitted for Fire Department review. Documents shall be of sufficient clarity and detail to fully describe the scope of work. Handwritten notes and comments on reproduced drawings are not acceptable. A. 1 B. 2 C. 3 D. 4

answer B. 2 907.1.2

Denver Building Amendments Light fixtures installed in Marijuana Operations Extraction rooms shall be installed in accordance with the NEC as a __________________ location. A. Class I, Div. 1 B. Class I, Div. 2 C. Class II, Div. 1 D. Class II, Div. 2

Answer A. Class I, Div. 1 3903.1.5 and 3903.2.2

Denver Building Amendments Smoking is prohibited where conditions are such as to make smoking a hazard, and in spaces where flammable or combustible materials are stored. True False

answer True IFC 310.2

Denver Building Amendments Installation of cables used for survivability of fire pump circuits shall comply with: A. NEC Article 695 B. UL 2196 C. Listing Requirements D. All of the above

Answer D. All of the above DBA 913.2.2

Denver Building Amendments In a high rise building, automatic smoke detection is required in all interior corridors which serve as a means of egress for Group _____, ______ and _______ occupancies with an occupant load of 10 or more. A. F1, F2 and F3 B. R1, R2 and R3 C. R1, R3 and R4 D. R1, R2 and R4

answer D. R1,R2 and R4 DBA 907.2.13.1(3)

Denver Building Amendment The radio system control channel in a high rise shall exceed -100dBm at 95% or more of the locations measured within each floor plate. Which of the following areas is not required to have 1000% signal coverage at -100 dBm? A. Parking Garage B. Fire Command Center C. Stairwell D. Elevator lobby

Answer A. Parking Garage DBA 907.2.13.2 DBA 510.1.1