DISCLAIMER & INSTRUCTIONS to Class A/B Operators

Slides:



Advertisements
Similar presentations
DISCLAIMER & INSTRUCTIONS to Class A/B Operators The slide presentation was developed to assist Class A/B Operators with providing Class C training. There.
Advertisements

General Safety Overview and Information
BLR’s Safety Training Presentations
Safety Training Presentation
Emergency Action And Fire Prevention
Dos & Don’ts at the Gas Pump
Static Electricity Rare Occurrence or Common Hazard?
Propane Refueling Procedures. Information on Propane  Propane (C3H8) is a hydrocarbon that is sometimes referred to as Liquefied Petroleum Gas (LPG)
 The Federal Clean Water Act specifies the requirements for SPCC Plans  The Code of Federal Regulations 40 CFR 112 details requirements of the SPCC.
Spill Prevention Control and Countermeasures (SPCC) Training.
Preventing Storm Water Pollution: What We Can Do ~Employee Training Series~ Fleet Maintenance PREPARED IN COOPERATION WITH THE Texas Commission on Environmental.
SAFE FUELING GUIDELINES FOR NONRETAIL FACILITIES
© BLR ® —Business & Legal Resources What’s the Big Deal? Flammable and combustible liquids: Are easily ignited and ignite with explosive force Burn.
Emergency Preparedness. Potential Emergencies at Cummins Types – Fire Serious injury (loss of life or limb) Tornado, flood, severe weather Large chemical.
SPCC Training Presented by: George S. Gamble, PE
Liquid Fuel Safety Cummins Southern Plains, Ltd..
Fire Safety Fires are one of the dangers most feared by health care providers. A fire or threat of fire can be extremely frightening to patients who may.
Standard 29 CFR Part Flammable & Combustible Liquids.
Release Reporting. Lesson #17 - Release Reporting How Do I Know If I Have a Leak in My UST System?
Management of Spills & Leaks Two areas of focus: Prevention: Taking steps to minimize the potential for a spill and properly maintaining equipment to eliminate.
1/05 School Safety Training Lab Safety WAC Part Q.
Safety Training Presentation
BASIC AUTO HAZARDOUS REGULATIONS. WASTE STREAMS RIGHT TO KNOW LAW n Hazard Communication Act of 1983 n Places some responsibility on Employer n Places.
Produced by the Northwestern Indiana Regional Planning Commission Community Partnership Produced by the Northwestern Indiana Regional Planning Commission.
Material Safety Data Sheet. The Material Safety Data Sheet provides the important information on every chemical you use this year. This information includes.
Safe Chemical Handling
Copyright  Progressive Business Publications Hazard Communication.
ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks.
BLR’s Safety Training Presentations
HAZWOPER: Awareness Level 29 CFR (q). Headline Stories Ammonia Evacuates Industrial Site Acid Spill Sends Workers to Hospital Fuel Spill Contaminate.
Hazard Communication Graphic
Copyright  Progressive Business Publications Handling Hazardous Wastes.
HAZWOPER: Awareness Level. Why is Hazardous Waste Dangerous? Chemical spills or releases can –Injure you or your co-workers –Contaminate drinking water.
Revised Spring 2007 Hazard Communication And Your Right - To - Know Dept of Environmental Safety Services.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
Courtesy of Schools Insurance Authority. Title 8, California Code of Regulations, Section 5194 Hazard Communication determines the dangers of the chemicals.
Cleaning Chemicals PPE Administration Engineering Substitution
Spill Prevention, Control, and Countermeasures Training (SPCC) Plan
LABORATORY SAFETY RULES Safety is everyone’s business! An awareness of current safety codes and regulation is necessary to make the laboratory a safe place.
Hazardous Waste.
Fire Extinguisher Training
Automotive Engines Theory and Servicing
Practical application of risk assessment: Use of pHA
Sump Water Management and Disposal ASTSWMO UST Workshop
GENERAL SAFETY PROCEEDURES & PRACTICES
Safe Handling of Flammable and Combustible Liquids
Laboratory Safety Rules
BASIC FIRE SAFETY.
Fire Extinguisher Training
Flammable and combustible liquids
FUEL STATION FIRE SAFETY
Release Reporting Lesson 17 covers the subject of Release Reporting. You will learn how you know when you have a leak and what leaks require reporting.
FIRE SAFETY Unit 2, Activity 2
Underground Storage Tank (UST) Operator Certification Overview
Flammable and Combustible Liquids
HAZARD COMMUNICATION (HAZCOM)
Gasunie is one of the biggest gas infrastructure companies in Europe
Chemical Transfer.
Fire Safety/Extinguisher Use
Waste Disposal / Zero Waste to Landfill
BASIC FIRE SAFETY.
Safe Handling of Flammable and Combustible Liquids
Acrylonitrile.
Vehicle & Equipment Maintenance/Cleaning
Weekly Safety Notes November 22, 2010 RESPONSE TO A SPILL.
ENVIRONMENTAL, HEALTH & SAFETY POLICY
Automotive Engines Theory and Servicing
Unit 1 Safety Power Mechanics.
Presentation transcript:

DISCLAIMER & INSTRUCTIONS to Class A/B Operators The slide presentation was developed to assist Class A/B Operators with providing Class C training. There are no backgrounds, transitions or other specials codes embedded in the PowerPoint, which allows you to insert your institution graphic, if desired. If you need help with inserting photos, text, & or graphic, please let me know. Site specific or institutional items are not required to be included in this training material. However, BOR recommends that a sufficient level of site specific information be provided per the discretion of the Class A/B Operator responsible for providing the training materials to Class C Operators. The State of Georgia requires a minimum that all Class C Operators be trained to: Location and function of emergency stop for pumps (slide 11) Basic emergency/notification procedures (slides 17-19 & 22) Location of spill kits materials (slide 20) Sign (wet signature or electronic) an acknowledge that training was received and completed (slide 25 & Separate MS Word file)

Operator Training Course Underground Petroleum Storage Tank Systems - Class C Operators Educational Resource for Class A & B Operators at USG Institutions & Skidaway

What should Class C Operators learn? Review of Basic and Site Specific Information (including, but not limited to): Definitions Emergency Procedures (alarms, spills, releases, fire extinguishers, first aid, notification, etc.); Familiarity with equipment function; Safety hazards of gasoline & related products; Fuel handling & dispensing;

Legal Basis Law Official Code of Georgia Annotated (O.C.G.A.) TITLE 12 Chapter 13 (Georgia Underground Storage Act) Energy Policy Act of 2005 (Federal) Rule GA Chapter 391-3-15 (Underground Storage Tank Management)

Definitions “Underground storage tank” or “UST” means any one or combination of tanks, including underground pipes connected thereto, which is used to contain an accumulation of regulated substances and the volume of which, including the volume of the underground pipes connected thereto, is 10 percent or more beneath the surface of the ground. “UST system” or “Tank System” means an underground storage tank and its associated ancillary equipment and containment system, if any.

What is not a UST? Examples (Check 391-3-15-.02 for specific exemptions) Types of tanks not regulated as USTs: Farm, residential, heating oil, septic, Flow-through process, hazardous wastes, stormwater, wastewater, & otherwise materials covered under other regulations; UST system whose capacity is 110 gallons or less; UST system that contains a “de minimis” concentration of regulated substances; Emergency spill or overflow containment UST system that is expeditiously emptied after use; and Certain piping systems

What is a Class C Operator in Georgia: “An individual who is the first line of response to events indicating UST emergency conditions, including but not limited to, taking appropriate action in response to emergencies or alarms caused by spills or releases from an UST system.” (391-3-15-.02)

Who is responsible for providing training? The Class A/B Operator responsible for the UST site must provide the Class C Operator training;

When is Class C training required? Prior to assuming responsibility for responding to emergencies of a UST with regulated fuel; Specific site training is required for each UST site; All regular USG employees (as designed by HR) with responsibility of dispensing fuel from a USG owned/operated underground storage tank must be trained to standards of the Class C requirements.

Training Exceptions Class C training is NOT required: if the USG UST dispensing site has a dedicated Class C attendant on duty during dispensing, (think of a typical gas station) Farm or residential tank (<1,100 gallon capacity) used for storing motor fuel for noncommercial purposes (2) UST Exclusions. The term “underground storage tank” or “UST” does not include any: (a) Farm or residential tank of 1,100 gallons or less capacity used for storing motor fuel for noncommercial purposes; (b) Tank used for storing heating oil for consumptive use on the premises where stored; (c) Septic tank; (d) Pipeline facility (including gathering lines) which is regulated under: 1. the Natural Gas Pipeline Safety Act of 1968 (49 U.S.C. App. 1671 et seq.), or 2. the Hazardous Liquid Pipeline Safety Act of 1979 (49 U.S.C. App. 2001 et seq.), or 3. which is an intrastate pipeline facility regulated under State laws comparable to the provisions of the law referred to in subparagraph (d)1. or (d)2. of this definition; (e) Surface impoundment, pit, pond, or lagoon; (f) Storm water or wastewater collection system; (g) Flow-through process tank; (h) Liquid trap or associated gathering lines directly related to oil or gas production and gathering operations; (i) Storage tank situated in an underground area (such as a basement, cellar, mineworking, drift, shaft, or tunnel) if the storage tank is situated upon or above the surface of the floor; (j) UST system holding hazardous wastes listed or identified under Subtitle C of the Solid Waste Disposal Act, or a mixture of such hazardous waste and other regulated substances; (k) Wastewater treatment tank system that is part of a wastewater treatment facility regulated under section 402 or 307(b) of the Clean Water Act; (l) Equipment or machinery that contains regulated substances for operational purposes such as hydraulic lift tank and electrical equipment tank; (m) UST system whose capacity is 110 gallons or less; (n) UST system that conta ins a “de minimis” concentration of regulated substances; (o) Emergency spill or overflow containment UST system that is expeditiously emptied after use; or (p) Pipes connected to any tank which is described in subparagraphs (a) through (o) of this definition.

What are the UST components? Class C Operators should be familiar with basic layout of the UST system INSERT Site Specific or generic (alarms, control panels, delivery point, etc) Typical Examples: Fuel Master Control (top), Leak Detection System (bottom) Provided by GEFA – Typical INCON System (fuel management system)(left) & Signage/emergency stop (bottom-right)

Example Layout Provided by GEFA

Fuel Handling Safety Guidelines Turn vehicles or equipment off prior to refueling. Don't smoke, light matches or use lighters while refueling. Always stay at the pump during refueling and do not re-enter the vehicle (static electricity). Do not over-fill or top-off your vehicle tank, which can cause gasoline spillage. Never allow children under licensed driving age to operate the pump.

Fuel Handling Safety Guidelines (cont) Avoid prolonged breathing of gasoline vapors. Use gasoline only in open areas that get plenty of fresh air. Keep your face away from the nozzle or container opening. Never siphon gasoline by mouth nor put gasoline in your mouth for any reason. Gasoline can be harmful or fatal if swallowed. If someone swallows gasoline, do not induce vomiting.

Dispensing fuel into a container Use only an approved portable container and place it on the ground to avoid a possible static electricity ignition of fuel vapors. Containers should never be filled while inside a vehicle or its trunk, the bed of a pickup truck, or the floor of a trailer. When filling a portable container, manually control the nozzle valve throughout the filling process.

Dispensing gasoline to container (cont.) Fill a portable container slowly to decrease the chance of static electricity buildup and minimize spilling or splattering. Keep the nozzle in contact with the rim of the container opening while refueling. Fill container no more than 95 percent full to allow for expansion. Place cap tightly on the container after filling - do not use containers that do not seal properly.

Dispensing gasoline to container (cont.) Keep gasoline away from your eyes and skin; it may cause irritation. Remove gasoline-soaked clothing immediately. Use gasoline only as a motor fuel. Never use gasoline to wash your hands or as a cleaning solvent.

What are some examples of emergencies? Fire Static electricity Smoking Filling hot machinery Fuel Releases/Spills: Delivery overflowing Pouring out of car Coming out of the ground Hose pulled off the dispenser Vehicle damages pump/dispenser Health Exposure Weather related disaster

Basic Emergency/Notification Procedures Hit the "Emergency Stop Button”; Call 911; (INSERT SITE SPECIFIC INFO)(i.e. 9-911) Evacuate customers & non-essential personnel and keep pedestrian and vehicular traffic out of the danger area as much as possible; Call your supervisor and/or the Class A/B Operator (whoever you have been instructed to notify); and Contain & mitigate any release, so that it doesn’t go down a storm drain or go in the grass or go off the site. There are five steps that should be taken --- and in this order if at all possible: First: Hit the "Emergency Stop Button.“ Second: Call 911. Third: Evacuate customers and non-essential personnel and keep pedestrian and vehicular traffic out of the danger area as much as possible. Fourth: Call your supervisor and/or the Class AlB Operator per the emergency instructions you have received. Fifth and finally and only if it can be done safely: Contain and mitigate any release -- so that it doesn't go down a storm drain or go in the grass or go off the site.

What should be posted at the site? A sign denoting the emergency stop button Emergency & Notification Procedures This is generally located near the control panel and UST records A list of trained operators (included UST records)

Spills & Cleanup Materials A Class C Operator should know: Location of any emergency materials, such as absorbent booms and pads, sandbags, and spill kits; How to recognize a spill; and Know basic response INSERT SITE SPECIFIC INFO & PHOTO

Basic First Aid Procedures If you come into contact with gasoline or diesel fuel, it is important that you follow these procedures: EYES: Flush with water for 15 minutes. SKIN: Remove any gasoline soaked clothing and wash exposed areas with soap and water. INGESTION: Call physician. DO NOT induce vomiting. INHALATION: Remove to fresh air upon being over come and/or experiencing an unusual symptom (i.e. Dizziness, irritation of eyes, nose and throat, vomiting, headaches, drowsiness, and other central nervous system)

Other Site Specific Emergency/Notification Procedures INSERT Site specific information (if not covered in previous slide)

Use of Fire Extinguishers Generally, fire extinguishers can be used by trained employees for flames not exceeding the size of a small trash pale. Use the P.A.S.S. (pull, aim, squeeze, & sweep) method when using a portable fire extinguisher. Otherwise, retreat to a safe distance and follow the site specific emergency procedures.

Review of Basic Class C Operator Requirements Are you aware of where the emergency numbers are located at the facility? Have you been instructed on emergency procedures for the facility? Should you ignore alarms or evidence of a release? Do you know how to shut down the pumps at the facility, in case of an emergency?

Class C Operator Training Acknowledgement & Checklist

Acknowledgements Bill Greer (G-TEC) American Petroleum Institute Purdue University Georgia Environmental Finance Authority Office of Facilities, Board of Regents of the University System of Georgia (Graphics Library)