3AH5 Vacuum Circuit-Breaker For Standard Applications

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Medium-Voltage Switchgear - Then and Now -
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Inspection & Preventive maintenance of breakers
M iniature circuit breakers to UL 489
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
During fault behavior of circuit breaker
Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
SMITH_USA_Author_ALPHA1_BLOCK1_Question 1-6 Barcelona May Question 1-6 Are There Fundamental Performance Limits for Vacuum Breaking Technology?
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
Assumption University Thailand EE4503 Electrical Systems Design Introduction 1.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
MV SF6 circuit-breakers for secondary distribution
Multi-function apparatus for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
1111Challenges for reliable offshore transformersTRANSFORMING YOUR NEEDS INTO SOLUTIONS Challenges for Reliable Offshore Transformers Dr. Jan.
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Pole Mounted Switch Disconnector NPS
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Frankfurt (Germany), 6-9 June 2011 Louise Jakobsen, Danish Energy Association – Denmark – Session 3 – Paper 0811 Louise Jakobsen, Danish Energy Association.
Medium Voltage Outdoor Apparatus Portfolio
Utility Engineers, PC.  Generation  Transmission  Distribution.
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
Submitted to: Submitted by:
A Presentation On 132 KV GSS BEHROR
Submitted to: Submitted by:
Air Blast Circuit Breaker
Electricity Notes 5 Electric Power – the rate at which _______________________ the rate at which _____________________ is converted into another form of.
Model A 19-inch Rack Static Transfer Switch. Why choose a model A static transfer switch? Break before make transfers Break time < ¼ Cycle Will not transfer.
Main contacts closed – RED Colour with ON
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Switchgear for Primary Distribution
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
6 Week industrial Training Presentation
Mikhail Ovsienko TE-MPE-EE
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
VMCL ELECTRONIC DIVISION.
POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS
Sub Station.
SUB-STATIONS.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
PRESENTATION ON SUMMER TRAINING PROGRAM
Name, department/event, date
Circuit Breakers & Reclosers
MV vacuum circuit-breakers for secondary distribution
POWER SYSTEM ANALYSIS INTRODUCTION.
High Voltage Power Circuit Breakers
SION Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
EHV Transmission Equipments
SWITCH GEAR AND PROTECTION(IV-1) TOPIC-CIRCUIT BREAKER
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Substation Equipment's
Presentation transcript:

3AH5 Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage © Siemens AG 2009 Sector Energy, Business Unit Medium Voltage

3AH5 Vacuum Circuit-Breaker Directory Technical Data Portfolio Product Features Details Applications September 2009

3AH5 Vacuum Circuit-Breaker 1. Technical Data Rated voltage up to 36 kV Short-circuit breaking current up to 31,5 kA Operating current up to 2500 A Mechanical operating cycles 10,000 (M2) Electrical operating cycles 10,000 (E2, C2) September 2009

3AH5 Vacuum Circuit-Breaker 2. Portfolio September 2009

3AH5 Vacuum Circuit-Breaker 3. Product Features Main Data 12, 17,5, 24 & 36 kV 800 to 2500 A 13,1 to 31,5 kA Up to 10,000 mechanical operating cycles Type tested according to IEC 62271-100 Your Benefit Usage for all standard application in medium voltage Compact dimensions Maintenance free up to 10,000 operating cycles September 2009

3AH5 Vacuum Circuit-Breaker 3. Product Features Column construction Vacuum interrupters are vertically arranged Free convection possible Solid insulation material is minimised as far as possible Your Benefit High mechanical stability Compact dimensions No forced-cooling up to 2500 A Very low fire load Easy access to all parts September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Hand crank coupling Push button “ON” Indicator „Closing spring charged“ Counter for “Operating cycles” Push button “OFF” Indicator „Closed/Open“ September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Operating unit Cooling element Auxiliary switch Gearbox Shunt release Opening magnet Closing spring September 2009

3AH5 Vacuum Circuit-Breaker 4. Details Secondary equipment Basic equipped Fully equipped September 2009

Comparison: Use of Insulation and Plastics 3AH5 Vacuum Circuit-Breaker 4. Details Comparison: Use of Insulation and Plastics 3AH5 column construction SION shell construction Competition embedded pole 12 kV 4 kg 13 kg 17 kg 14 kg 23 kg 2500A Phase barrier drive 10 kg PMA 160 mm Phase barriers 17,5 kV 16 kg PMA 150/160 mm   Phase barrier contact arms September 2009

Applications for 3AH5 5. Switching of Standard Applications Requirements Switching of transformers, drives, capacitors, filter circuits, overhead lines and cables Synchronising of parallel networks Rapid load transfer of consumers to other incoming feeder Auto-reclosing in overhead lines to clear transient faults or short-circuits Switching of short-circuits Industry Application “Refinery” September 2009

Thank you very much for your attention! Please press ESC to return to the overview. September 2009