Hazardous Area Classification 1. Hazard & Its Causes/ Types 2. Hazardous Area Definitions 3. Material Classification 4. Area Classification 5. Prevention.

Slides:



Advertisements
Similar presentations
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Advertisements

(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
A PPARATUS G AS G ROUPS, T EMPERATURE C LASS AND T YPES OF E XPLOSION P ROTECTION (Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
VSD AND SS DRIVING ATEX MOTORS February Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
PROPERTIES OF FLAMMABLE MATERIALS. Flammability Flammable Flammable –Capable of being ignited and of burning –Synonymous with combustible.
1 Module 3 Ignition Control. 2 Terminal Objectives Upon the successful completion of this module, participants will be able to explain the work procedures.
Fires and Explosions.
Work In Confined Spaces
NEW TECHNOLOGY IN MINE SURVEYING AND ITS IMPACT ON SAFETY IN THE UNDERGROUND WORKINGS OF A MINE.
The Association of Electrical Equipment and Medical Imaging Manufacturers ENCLOSURE TYPES Environmental Conditions : and the Appropriate:
CERTIFICATION OF EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES What do I Really Have to Do ?
Safe Handling of Flammable and Combustible Liquids
Hazardous Location Standards and the CEC
2 THEME The important thing from the point of view of fire safety is – how one interprets these properties. Thorough knowledge is essential to understand.
Liquid Fuel Safety Cummins Southern Plains, Ltd..
Page 1 February US-Project: Module Portfolio GP DrivesNadja Reiner, SE&A Inc. - Confidential - s Basic understanding of ratings General information.
Kyland-USA / DYMEC INGRESS PROTECTION RATINGS EXPLAINED. Copyright © KUSA, LLC. All rights reserved.
Copyright © Flammable & Combustible Liquids.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Chapter One Electrical Design and Component Basics.
Flammable and Combustible Liquids
Fieldbus 1 FISCO. Fieldbus Certified Transmitter : Intrinsically safe IIC/Group A T4 Ui : 30V Ii : 100mA Ci : 0.01  F Li : 100  H C c : 0.12  F L c.
Electrical Installation 2
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
HOW TO DETERMINE EXPLOSIVE ATMOSPHERES Author: Mihai Magyari, Ph.D.Eng. INSEMEX PETROSANI ROMANIA G-ral. Vasile Milea Street, Petrosani, Hunedoara.
Fire Safety. Fire Safety Introduction Fires ravage 28,000 industrial facilities each year, causing $596 million in direct property damage. Ninety percent.
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
PLANT DESIGN.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Basic Awareness Training for all Staff
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
FLAMMABLES. 1. PROPERTIES OF FLAMMABLES Combustion (redox) reactions Solids, gases, most commonly liquids Fire Tetrahedron Ignition sources External-
The work of CEN/TC 305 Potentially explosive atmospheres-
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Selection of Explosion Protected Equipment for Hazardous Locations
© 2012 Delmar, Cengage Learning Chapter 7 Fire and Explosions.
What is a safe work permit? A safe work permit is a written record that authorizes specific work, at a specific work location, for a specific.
SAFETY WITH CRYOGENIC SYSTEMS. Safety aspects 1. Physiological 2. Suitability of materials and construction 3. Explosions and flammability 4. Excessive.
FLAMMABLE AND COMBUSTIBLE LIQUIDS 1 Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) OSHA 29CFR PPT
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
Chapter 7 Fire and Explosions. Fires, Explosions, and Detonations The lowest temperature at which an air- hydrocarbon mixture will explode or burn is.
Samuel Nii Tettey (Ergonomist). At the end of Session, participants should be able to: - Identify fire problems at the enterprise level and Conduct Fire.
Flammable Liquids Directorate of Training and Education
Standards Certification Education & Training Publishing Conferences & Exhibits ISA SP12 Standards Related to Equipment in Hazardous Locations.
Rev. 1 © Chevron 2009 Hot Work Awareness Plus. Rev. 1 © Chevron Training Objectives  To explain the type of work which may constitute Hot Work.
WORKING IN CONFINED SPACES Samuel Nii Tettey (Ergonomist) 1.
1 ATEX classification air motors, Dagmar Dübbelde ATEX CLASSIFICATION AIR MOTORS.
Safe Handling of Flammable and Combustible Liquids.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
NONINCENDIVE INSTALLATIONS FOR CLASS I DIV 2 AREAS
Safe Handling of Flammable and Combustible Liquids
WELCOME LEARNERS! UpStream (API RP 14FZ, API 500 and API 505)
Hazardous Area Environments
U.S. participation in IECEx Scheme
THUM Adapter Impact on Hazardous Area Classification
ATEX fans st ATEX.
Flammable and Combustible Liquids
مایعات قابل اشتعال و احتراق پذیر
CONSTRUCTION BS (BS 4533) K.F. Chan (Mr.) MEBS 6002.
Electrical Safety Standards
Chapter 7 Fire and Explosions
Dangers and Uses of Static Electricity
Protection against over voltages
Flammable & Combustible Liquids
Safe Handling of Flammable and Combustible Liquids
Hazardous Area Classification
Parker domnick hunter. Safety of Electrical and
Two Minute Drill – Residential 3
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Hazardous Area Classification 1. Hazard & Its Causes/ Types 2. Hazardous Area Definitions 3. Material Classification 4. Area Classification 5. Prevention

1. Hazard & Its Causes/ Types Introduction:Introduction: Any area in plant where manufacturing processes emit/ may emit gases, vapours or mists if mixed with air in correct proportions will produce explosive medium. For an ignition to occur there must be:For an ignition to occur there must be: –A Hazard –A Source of Energy (Ignition or Hot Surface) –Air (To Support Combustion)

1. Hazard & Its Causes/ Types Fire Triangle:Fire Triangle: Temperature Fuel Air

1. Hazard & Its Causes/ Types TerminologyTerminology : –Flammable Mixture: –Flammable Mixture: Rich flammable fuel/ air combination in atmospheric conditions –Hazard: –Hazard: The Presence/ Risk of presence of flammable mixture –Hazardous Area: –Hazardous Area: An area where during normal operations, a flammable mixture is likely to be present. The material involved is Crude oil & its derivatives, natural & synthetic process gases, Hydrocarbons, Metal dusts, fibers etc.

1. Hazard & Its Causes/ Types –Non-Hazardous (Safe Area): –Non-Hazardous (Safe Area): An area, which is neither Hazardous nor remotely hazardous. –Electrical Apparatus For Hazardous Area: –Electrical Apparatus For Hazardous Area: The apparatus which will not ignite the surrounding Hazardous Atmosphere, where it is used. –Types of Protection: –Types of Protection: Specific measures applied to electrical apparatus to prevent ignition in Hazardous Area.

1. Hazard & Its Causes/ Types Combustion Polymers Explosive Corrosive Ignition

1. Hazard & Its Causes/ Types Spontaneous Combustion: Many hazardous material have property known as auto ignition; Temperature at which ignition occurs without source of ignition. Polymers:

2. Definitions Prime Considerations:Prime Considerations: –Ease of Ignition: –Ease of Ignition: The type of Material is classified as per property of various materials for ease of ignition. –Area classification basis: –Area classification basis: Area over Hazard may extend. –Auto-Ignition Temperature: –Auto-Ignition Temperature: Temperature Class of Apparatus Used.

3. Material Classification Standards Followed :Standards Followed : –Europe: –Europe: CENELEC & IEC –North America: –North America: NEC IEC : Gases and Vapours in two groupsIEC : Gases and Vapours in two groups: –GR I : –GR I : Mining (Sub-Surface) Industry –GR II : –GR II : Surface Industry; Sub-Groups A,B,C.

3. Material Classification As per NEC :As per NEC : –Class 1: –Class 1: Gases & Vapours; further divided into 4 groups: A,B,C,D. –Class 2: –Class 2: Combustible Dusts; further divided into 3 groups based on their resistivity: G,E,F. –Class 3: –Class 3: Combustible fibers or flyings.

3. Material Classification Gas Grouping Gases belonging to IIC are most dangerous with severity decreasing to IIA.

3. Material Classification Flammable LiquidsFlammable Liquids –Classified on basis of Flash Point. –Class A: –Class A: Flash Pt < 23 o C. They produce large volumes of vapour –Class B: –Class B: 23 o C<Flash Pt<65 o C –Class C: –Class C: 65 o C<Flash Pt<93 o C

4. Area Classification BasisBasis –Probability of presence of explosive mixture. –IEC –IEC: 3 zones (Zone : 0,1,2) Zone 0:Zone 0: Explosive Mixtures continuously present / Present for long (>1000 Hrs/Yr). e.g. Inside Tanks, Vessels etc. Zone 1:Zone 1: Explosive Mixtures likely to occur in normal operation / (Between 10 to 1000 Hrs/ Yr). eg Production Area, area surrounding zone 0.

4. Area Classification Zone 2:Zone 2: Explosive Mixtures not likely to occur /occur short duration in normal operation (<10 Hrs/ Yr). NEC:NEC: 2 Divisions (Div: 1 & 2) –Division I: –Division I: Comprising of Area Same as Zone 0 & 1. –Division II: –Division II: Comprising of Area Same as Zone 2.

4. Area Classification The max surface temp. of exposed surface of equipment must always be lower than Auto- Ignition Temp of the Prevailing Gas. Class T1 T2 T3 T4 T5 T6 Temperature( o C)

5.Prevention Methods 5.1Selection Process 5.2Protection Methods 5.3Intrinsic Safety 5.4Enclosure Protection

5.Prevention Methods 5.1Selection Process –Selection of electrical apparatus is based on likelihood of the simultaneous presence of hazardous area and source of ignition –Steps: 1. Identify the gas/ vapour. 2. Define the Zone ie 0 or 1 or Select type of protection appropriate for the zone. 4. Select equipment based on gas group and temperature class.

5.Prevention Methods –Required Information –Required Information : 1. Zone of the Area 2. Ignition Temp of gas/ vapour involved or lowest value of ignition temperature if more than one explosive material is involved. 3. Characteristic of gas/ vapour related to: –Ignition current (in case of IS apparatus) –Safe gap data (in case of FP apparatus)

5.Prevention Methods 5.2Protection Method: Methods are “Zone” dependent ie: Zone Zone Zone 2

5.Prevention Methods Zone 0: No electrical apparatus allowed OR When not practical only intrinsically safe apparatus is allowed. Protection Method Protection Method: Intrinsic Safety: (IS) A circuit or part of it is IS when any spark or thermal effect is incapable, under prescribed conditions, of causing ignition of prescribed gas/ vapour. Cat Ex-ia : Sustainable to Two Faults Cat Ex-ib : Sustainable to One Fault

5.Prevention Methods Zone 1: –Type of protection as applied to Zone 0. –Flameproof, Pressurized, Sand filled, Oil Immersed. Protection MethodsProtection Methods: 1. Flameproof Enclosure: (Ex-d) Apparatus will withstand and not pass to outside ; an internal explosion of flammable mixture, which may originate inside enclosure. 2. Pressurized Enclosure: (Ex-p) Apparatus in which, the entry of flammable mixture is prevented by maintaining air pressure within the enclosure above atmospheric pressure.

5.Prevention Methods Protection MethodsProtection Methods: 3. Sand filled : (Ex-q) An apparatus that has alive parts embedded in powdery material. 4. Oil Immersed : (Ex-o) An apparatus that has alive parts embedded in oil to a sufficient depth to prevent ignition.

5.Prevention Methods Zone 2: –Type of protection as applied to Zone 0 or Zone 1. –Other methods are: Protection MethodsProtection Methods: 1. Non-Sparking Apparatus: (Ex-n) Apparatus that is not capable of igniting surrounding. 2. Increased Safety Apparatus: (Ex-e) Increased security against excessive temperatures and occurrence of arcs/ sparks. 3.Hermetically Sealed: (Ex-s) Enclosure is so designed that gases can’t enter in it.

5.Prevention Methods 5.3Intrinsic Safety: –Based on min ignition levels established for various flammable mixtures. –Limits availability of energy even in fault conditions to < min ignition energy. –Ex-ia suitable for all zones. –Ex-ib suitable for zones 1 & 2. –Achieved by using Zener Barriers or Galvanic Isolators.

5.Prevention Methods Zener Barrier:Zener Barrier: –In event of fault Zener diodes limit the voltage that can reach hazardous area and resistor limits current. –Requires safe grounding; otherwise will not function. Galvanic Barriers:Galvanic Barriers: –Isolated by transformers. –Voltage regulator provided. –Does not require grounding. –Designed for special applications. –Preferred now-a-days.

5.Prevention Methods Entity Concept:Entity Concept: –Modular approach to assemble IS systems. –User to identify acceptable combinations of intrinsically safe apparatus and associated apparatus. –Intrinsically safe apparatus is assigned Vmax, Imax, Ci, and Li. –Associated apparatus is assigned Voc, Isc, Ca, and La. –The length of cable connecting intrinsically safe equipment with associated equipment maybe limited because of the energy-storing characteristics of the cable.

5.Prevention Methods Simple And Non-Simple Apparatus:Simple And Non-Simple Apparatus: –Simple Apparatus: Purely resistive devices. Does not exceed 1.2v, 0.1A, 20 microjules, 25 mwatts. Hence, does not require certification. Eg: Thermocouples, RTD, Photocells, LEDs. Cable Parameters for ISCable Parameters for IS: –Energy storage due to L, C & L/R. –Voltage Limitation: 1/2 CV 2 –Current Limitation: 1/2 LI 3

5.Prevention Methods Earthing Requirements:Earthing Requirements: –High integrity Earth –Dual Earth Cable –Max impedance < 1 ohm –All screens of IS cables to be properly earthed –No Earth Loops (Single Earthing)

6. Conclusion Precautions/ Guidelines:Precautions/ Guidelines: –Permit System Work Permits Hot Permits –Usage of Proper Tools and Tackles Avoid spark, use non-sparking tools. Use IS Multimeters

5.Prevention Methods 5.4Enclosure Protection: –Environmental & Hazardous Suitability- NEMA codes ie protection against –Falling Dirt, Oil spraying, splashing, Rain etc Also Specifies for Hazardous Locations –ie Class-IC requires type 7C/ 8C. –Ingress Protection - IP Table Specifies degree of protection against solids and liquids. –Ie IP-65 for complete protection for solid ingress and against water jets for liquid.