CI-202 Leaf Area Meter Instrument Training Conducted by: Brienne Meyer

Slides:



Advertisements
Similar presentations
“The Digital Recorder and Voice Memos” Presented by Maria E. Delgado
Advertisements

Tutorial 9 – Creating On-Screen Forms Using Advanced Table Techniques
Product Presentation. WHAT IS IT? Product Presentation.
MHSL - Dolphin Training Class
The EZ-SAT.
PRESS C7000/C7000P/C6000 Color Density Control Color Balance
Digital Solutions Saving and Restoring the PLC.
LogTag Training January 2015
Teaching Room User Guide – Using the AV Pod, Projector and Screen If the touch panel is blank, press firmly to wake up. Start up the Pod To turn on the.
Unit Test Calibration Training
User Guide and Trouble-shooting Information. A classroom set of 20 cameras are available for teacher and student use. Capable of taking video, but recommend.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Introducing the Canon Powershot 410 Digital Still Camera Click to advance to the next page.
Final Exam Test Review Intro To Computers.
EPOCH 1000 File Management Data Logging and Reporting
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Exceed Series Decorative Stitch Patterns The Exceed series also has a Decorative Pattern menu where intricate patterns can be selected. The Exceed Quilt.
Manual of AWA6228 II).Several Basic Setups Hangzhou Aihua Instruments Co., Ltd.
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
AccuMax Multi-Point Injection Mechanics
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Garmin GPS III Plus Data Collection. Objectives Collect: - Waypoints -Average Position Waypoints -Reference Waypoints - Multiple Tracks in One Track Log.
Usage Guidelines Throughout this template you will find tip-boxes to the left of the slides. To remove this box from the final presentation, simply click.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Druck- und Temperaturmesstechnik GSoft / Testing and Callibratiion Technology / Testing- and Calibration Technology Data logger evaluation software.
A lesson approach © 2011 The McGraw-Hill Companies, Inc. All rights reserved. a lesson approach Microsoft® PowerPoint 2010 © 2011 The McGraw-Hill Companies,
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Working with GPS Stephen M. Kiama (MSc) [Geo-information Specialist]
EZ-3 ECG. Thank you for your interest in Futuremed’s EZ-3 ECG. Like other EZ-3 users, we are confident you will enjoy this model ideal for obtaining sharp.
Key features of Windows 7 as used in CIS 121 Introduction to Computer Information Systems 1.
TrekView DMS Instructions. 1. Log in to TrekView DMS.
H2 Zoom Recorder Operational Procedure. In the box All H2 Zoom kits contain –1 GB SD Card –Mic Clip Adaptor –Wind Screen –Earbuds –USB Cable –AC Adaptor.
Weston Schreiber & Joshua Gabrielse Robotics Summer Training Programming #1: EasyC Basics.
Move Pictures From Your Mobile Phone to Your PC.  You never know when a photo opportunity is going to arise, which is why having a camera phone can be.
Thank you for your decision to try vTreePro Practice Tree Software! Your satisfaction is very important to us. Please feel free to send us an if.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Selecting, Formatting, and Printing a finished Report…….
VistA Imaging Capture via Scanning. October VistA Imaging Capture via Scanning The information in this documentation includes only new and updated.
How to Install Malwarebytes Anti- Malware Software Khushbu Shah ENG 393 May 4 th, 2010.
Intuitive Programming System For The Mill
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
Training on Basic Software Hardware Installation
Garmin GPS III Plus Setup for Data Collection
Confidentiel –Usage interne Presentation RayCAm CA 1884.
IMovie 10 Overview. Importing Files from a Video Camera into iMovie 1.Plug the camera into a wall outlet using the power supply. (Some cameras will not.
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Garmin GPS III Plus Setup for Data Collection. Objective Select settings appropriate for each project.
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
OFL2Go Utility to copy OTDR trace files from an OFL250 or OFL280 to a PC, with fiber folders removed. Quick Reference Guide.
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
1 Philips EvoKit Lumen Selection App User Manual * Philips Lighting April 20, 2016 *Can be used for Philips EvoBase as well.
CI-110 Plant Canopy Analyzer Instrument Training Conducted by: Brienne Meyer
How to Sync Android Phone to Computer (PC/Mac)? Are you a person that always has your Android phone in your hands? Nowadays, a cell phone is not just for.
CI-203 Instrument Training Conducted by: Brienne Meyer
Cold-Chain Expert, Total Solution Quality Precision Service Value
CI-600 & CI-690 Product Training
Ping™ 6.
Powertap User Guide.
Classroom Digital Camera
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
Unable To Complete The Norton Download. Norton protects a device from all sorts of security danger. With the great use of internet, the chances of viruses.
Conference room user manual
724 Temperature Calibrator
Presentation transcript:

CI-202 Leaf Area Meter Instrument Training Conducted by: Brienne Meyer

CI-202 Portable Leaf Area Meter Fast, non-destructive measurements – Length – Width – Area – Perimeter – Aspect Ratio: leaf length to its maximum width – Shape factor: ratio of leaf area to leaf perimeter Shape factor of a circle = 1

CI-202 High resolution of 0.1mm Transfers data to computer via USB connection Scan board with plastic sheet or cover – Protects fragile or delicate leaves – Leaf can still be attached to plant or removed – hand-hold on back for easy use in field

CI-202 Specifications Scanner:675 nm Laser Diode Max. Measuring Length:36cm Max. Measuring Width:150mm Max. Measuring Thickness:15mm Max. Scanning Speed:127 mm/second Area Units:cm 2 Accuracy:±1% for samples > 10cm² Data Storage:8,000 Measurements Computer Interface:USB 2.0 Display:16 characters × 2 line LCD Battery:7.2V rechargeable NiMH Battery Life:15hrs Operating Temperature:0-50ºC Weight:1.50 Kg

CI-202 Use Create a File to save measurements to – File<Create Start taking and saving measurements – Autosave feature Can also measure the length of harvested, washed roots – Put CI-202 in Root Mode – Place roots under plastic sheet on scan board

CI-202 Menu System Measure View File Setup Use the Up/Down arrow to select a menu Use the right arrow to select a sub-menu

Measure Menu The options are: to select another mode with the up or down arrow keys to select another file (if there is more than one file) with the right or left arrow keys to take measurements

Taking a Measurement Place leaf under plastic sheet on scan board Position CI-202 scan head at top of scan board – Catch at end of scan board rail Press “enter” or “start.” Display will read “Stabilizing”--“Spinning Up”— “Measuring” Move the scan head down scan board

Results on the CI-202 File name Parameter Parameter value Press right/left arrow to bring another parameter into view Press Save to save measurement Press Stop to discard the measurement

View Data Menu Files Voltage Battery After select a file, press ENTER to see data Press Up to see “total” data Press Up again to see “average” data

File Menu Clear Delete Create Close – move all temporary records to file system You must always create at least 1 file before measuring.

Transfer Data to PC Use USB cable Install LIBUSB driver for CI-202 Run CI202DF.exe program – Transfer files from 202 Save files as.csv Re-open in Excel

Setup Menu Use the Right/Left arrows to select the desired Setup option Press the Start/Enter to enter the sub-menu Measure (leaf/root) Scanner Autosave (yes/no) Storage

Setup Measure Leaf Area Root Length Up/down to modify value Press Save to save Press Stop to abort

Setup Scanner Thresholds Normally, there is no need to adjust the threshold of the CI-202. The CI-202 is factory-adjusted to a threshold level that is ideal for “all-around” use. If out-of-the-ordinary measurements are being recorded or if the instrument has suffered from abuse or excessive aging, the manual threshold setting may need to be adjusted. Follow instructions in CI-202 User Manual to adjust width and length calibration

Setup Storage Check memory space or erase 16 bytes use per measurement recorded Use “Format Storage” to erase all data and all files (up/down arrow) – Good when starting a new project or new year

Setup AutoSave When “Yes” is on display, all leaf measurements will be saved automatically Use Up/down arrow to change option Press Save to save Press Stop to abort

Re-compute the Timing Parameters This procedure should be carried out whenever the CI-202’s threshold settings are changed or if the instrument isn’t measuring accurately. Re- computing the parameters will recalculate the effects of any changes made on the other parameters. From the "Measure" menu, press the LEFT and RIGHT arrow keys at the same time. Hold the buttons until the motor begins to spin. The motor should spin for about 4 seconds. Do this twice by pressing the LEFT and RIGHT arrow keys simultaneously again and making sure that the motor spins up. Take a test measurement and try to determine if the Length or Width readings need adjustment.

Technical Support Brie or Skype: cidbiosciencesupport Phone: – FAQs – Software – Troubleshooting – Support Forum

CI-203 Provides additional data beyond leaf area: – Length, width, perimeter, voids, aspect ratio, shape factor, GPS tagging – Graphic display of leaf image for verification of successful scan – Removable SDcard for easy data transfer (or USB)

CI-203 Handheld Leaf Area Meter Non-destructive measurement by sliding leaf under arm CI-203 CA: Conveyor – Rapid measurements – Destructive, harvested leaves – Requires external power supply