Fluorescent Detection using Optical Fibers with Cardiac Myocytes Paul Clark Martin Garcia Chris Gorga John Ling III Giordano Lo Regio.

Slides:



Advertisements
Similar presentations
Selected Biosensors Yu Cao Oct 28, Yu Cao Outline Two categories of biosensors –I: Electrical sensors –II: Optical sensors.
Advertisements

Single Cell Biosensor Allan Fierro David Sehrt Doug Trujillo Evan Vlcek Michael Bretz.
Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant Advisor: Dr. John Wikswo, Dr. David Cliffel.
MEMS Tuning-Fork Gyroscope Group 8: Amanda Bristow Travis Barton Stephen Nary.
John D. Williams, Wanjun Wang Dept. of Mechanical Engineering Louisiana State University 2508 CEBA Baton Rouge, LA Producing Ultra High Aspect Ratio.
MEMS in the Market – Design and Market Analysis MEMS in the Market – Design and Market Analysis Ryan Dempsey, Peter Shanahan, John Richardson, Rachel Weaver,
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Microfluidic Valve Innovation Jo Falls Porter, RET Fellow 2009 West Aurora High School RET Mentor: Dr. David T. Eddington, PhD NSF- RET Program Introduction.
Lab-on-a-chip Devices for Cell Separation and Identification A PhD project at Macquarie University under the guidance of Dr. David Inglis and Prof. Ewa.
Design of Health Technologies lecture 12 John Canny 10/17/05.
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography EECE 491C Unger et al. (Quake group, CALTECH) Science, 2000.
Sensing and Actuation in Miniaturized Systems Sensing and Actuation in Miniaturized Systems PRESENTATION DNA Transformation by Local Heat Shock
Rydberg excitation laser locking for spatial distribution measurement Graham Lochead 24/01/11.
Development of a thermal cooling system for a PMT (Photo Multiplier Tube) Summer Researcher Yasmine Salas Colorado State University Advisor: Dr. Julia.
Page 1 © J.Paul Robinson, Purdue University Cytometry Laboratories BMS 602 LECTURE 9.PPT BMS LECTURE 9 Flow Cytometry: Theory Hansen Hall,
Damian Ashmead Adam Binkley Angela Huenerfauth Beth Miller Jonathan Rashidi.
Conceptual Design Review Senior Design
Soft Lithography Practicum MAE 165 Spring 2010 Professor Madou Tuesday Group: Jeff Draper Amanda Evans David Szeto.
Applications of SPCE to Pharmaceutical Research Kathleen Hamilton, Tom Laue, and James Harper Presentation at the 2007 BITC Meeting University of New Hampshire.
Blood Separation in Microfluidic Devices Group #5 Eric Chung Scott Darby Casey Reynolds Jeff Turner.
Basic Silicone Chemistry (II)
PULSE MODULATION.
CMOS and Microfluidic Hybrid System on Chip for Molecule Detection Bowei Zhang, Qiuchen Yuan, Zhenyu Li, Mona E. Zaghloul, IEEE Fellow Dept. of Electrical.
Development of a Modular Peristaltic Microfluidic Pump and Valve System 3/13/2007 BME 273 Group 20: Adam Dyess, Jake Hughey, Michael Moustoukas, Matt Pfister.
A Bandwidth Detection System to Monitor Single Cells Jerry J. Wilmink, Jonathon D. Wells, Advisor: Franz Baudenbacher Department of Biomedical Engineering.
Powerpoint Templates Page 1 Powerpoint Templates Optically induced flow cytometry for continuous microparticle counting and sorting Student: Chin – wei.
Status of the FETS Laserwire Scanner David Lee UKNFIC Meeting
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Prototyping Techniques: Soft Lithography
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Development of a Modular Microfluidic Peristaltic Pump and Valve System Jacob Hughey ¶, Matt Pfister ¶, Adam Dyess ¶, Michael Moustoukas ¶ Advisor: John.
Excitation of Vibrational Eigenstates of Coupled Microcantilevers Using Ultrasound Radiation Force ASME 2nd International Conference on Micro and Nanosystems.
NucleoCounter YC-100 Presentation
BioSensors Yang Yang 9/28/2004. Outlines BioMEMS Enzyme-coated carbon nanotubes Microcantilever biosensor with environmentally responsive hydrogel Cantilever.
Objectives Division of Work Background Mirror Fabrication Cavity Fabrication Biomaterials Sample Preparation Test Procedure Results Timeline Future Work.
BIOPARTICLE SEPARATION AND MANIPULATION USING DIELECTROPHORESIS Advisor: Yi-Chu Hsu Student: Le Van Cong ( 黎 文 功 ) Date: 11/04/2011.
M. Gilchriese Module Assembly and Attachment at LBNL M. Gilchriese for F. Goozen April 2000.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
 Sol-gel grating coupler fabrication by solvent assisted micromoulding (SAMIM).  Comparison of grating couplers fabricated by SAMIM with those fabricated.
Improvement of Infrared Lights Sensitivity on PZT EMITER Daisuke Takamuro, Hidekuni Takao, Kazuaki Sawada and Makoto Ishida.
Figure 23.1: Comparison between microfluidic and nanofluidic biomolecule separation. (a) In microfluidic device, friction between liquid and the molecule.
Design Team 8: Fluorescent Detection using Optical Fibers with Cardiac Myocytes Team Members: Paul Clark Martin Garcia Chris Gorga John Ling III Giordano.
BME 273 Senior Design Project Group 25 “MEMs in the Market”
Determination of Intercellular Calcium Concentrations in Cardiac Myocytes Using Fluorescence and a Single Fiber Optic Method Paul Clark, Martin Garcia,
BME 273 Senior Design Project Group 25 “MEMs in the Market”
Process Sequence: Pressure-Actuated Valve ENMA490 October 14, 2003.
BioMEMS: Microfluidics Optimization & Cell Culture Maintenance D. Michael Ackermann, John Payne, Hillary Samples, James Wells Group # 23 Advisor: Franz.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
Fully-integrated microfluidic chips capable of performing DNA amplification from RNA virus, sample transportation, capillary electrophoresis separation,
Acellular microfluidic lung on a chip design for gas exchange Introduction Design Methods Conclusions Acknowledgements Mathematical Analysis Integration.
FLUORESCENT DETECTION USING OPTICAL FIBERS WITH CARDIAC MYOCYTES DESIGN GROUP EIGHT FLUORESCENT DETECTION USING OPTICAL FIBERS WITH CARDIAC MYOCYTES Paul.
Instrumented NanoPhysiometer for High Throughput Drug Screening D. Michael Ackermann, Jon Payne, Hilary Samples, James Wells.
C A microfluidic device was created in order to mix the contents of two reservoirs through a 200um-wide, 30mm-long diffusion channel. Flow Characterization.
MICROCHANNEL DESIGN ISSUES Susan Beatty Anne Samuel Kunal Thaker.
Microfluidic Glucose Sensor Senior Design Group 4
Develop a Bandwidth Detection System to Monitor Metabolic Activity of Single Cells  Jerry Wilmink and Jonathon Wells  Advisor: Franz Baudenbacher  BME.
Lab-on-a-Chip The Ideal Technology for Bio-chemical Analysis
Design Team 8: Fluorescent Detection using Optical Fibers with Cardiac Myocytes Team Members: Paul Clark Martin Garcia Chris Gorga John Ling III Giordano.
Utah Nanofab Design Review Meeting Device Architecture (Top View Layout and Layer Cross Section) Recipes & Settings Standard Concept Equipment & Tools.
Synthesis and Evaluation of anti-Nonspecific Binding Coating in Microfluidic Devices for ELISA Bioassays Melissa J. Gelwicks.
Chapter 1 & Chapter 3.
Speed Sensor Calibration
A non-amplification molecular probe approach John Gerdes, Ph. D.
A Bandwidth Detection System to Monitor Single Cells
Molding PDMS Channels and an Embedded Detector Chamber
Supported by NIH Grant EB
Determination of Intercellular Calcium Concentrations in Cardiac Myocytes Using Fluorescence and a Single Fiber Optic Method Paul Clark, Martin Garcia,
Determination of Intercellular Calcium Concentrations in Cardiac Myocytes Using Fluorescence and a Single Fiber Optic Method Paul Clark, Martin Garcia,
Presentation transcript:

Fluorescent Detection using Optical Fibers with Cardiac Myocytes Paul Clark Martin Garcia Chris Gorga John Ling III Giordano Lo Regio

Thesis Device that is more cost efficient. Device that is more cost efficient. Incorporate optical fibers into an existing BioMEMS device Incorporate optical fibers into an existing BioMEMS device The optical fiber or fibers will detect the fluorescence of calcium in contractile cardiac myocyte cells The optical fiber or fibers will detect the fluorescence of calcium in contractile cardiac myocyte cells This design can potentially be used to measure fluorescence of any ion of interest This design can potentially be used to measure fluorescence of any ion of interest

Questions Optical Fibers Optical Fibers –What is the minimum fiber diameter to produce accurate and differentiable results? –Will a single fiber setup work? How successfully can we integrate an optical fiber into our PDMS device? How successfully can we integrate an optical fiber into our PDMS device? How adaptable this device will be for other ions? How adaptable this device will be for other ions?

Background Completed micro fluidic device already known to successfully hold cardiac myocytes. Completed micro fluidic device already known to successfully hold cardiac myocytes. Online detection of calcium using chemical analysis Online detection of calcium using chemical analysis Already have large scale design of this process using inverted microscope and multiple cell cultures. Already have large scale design of this process using inverted microscope and multiple cell cultures. Fura-2 dye specification Fura-2 dye specification Pre-designed Photo Multiplier Tube (PMT). Pre-designed Photo Multiplier Tube (PMT).

Objectives Modify micro fluidic device to accept optical fiber. Modify micro fluidic device to accept optical fiber. –Change consistency of PDMS –Find correct positioning to achieve maximum output signal Integrate small scale fiber optics with PMT Integrate small scale fiber optics with PMT –Adjust to smaller signal –Increase sensitivity –Design LabView module to analyze, graph, and store input signal

Importance Provide integrated system to quantify a host of intracellular molecules Provide integrated system to quantify a host of intracellular molecules –Charged Ions –Intra-membrane Proteins Could be used to examine intracellular molecules in several single cells (not exclusively myocytes) Could be used to examine intracellular molecules in several single cells (not exclusively myocytes)

Social/Economic Impact Compact device marketed to academic research institutions Compact device marketed to academic research institutions Alleviate start up costs for smaller institutions Alleviate start up costs for smaller institutions More time and money devoted to experiment rather than device development More time and money devoted to experiment rather than device development Focus on study of cell and its physiology Focus on study of cell and its physiology

Status Optics of the PMT box are being studied Optics of the PMT box are being studied –Magnitude of the signal –Signal amplification into Labview for data aquisition –Will allow for the addition of the chopper Gives specific excitation frequency (kHz) Gives specific excitation frequency (kHz) A master for the PDMS micro-fluidic device has been designed A master for the PDMS micro-fluidic device has been designed –Waiting on mask to be cast Outlined next 3 weeks Outlined next 3 weeks

Photomask Specifications Channels (3) are 200 microns wide Channels (3) are 200 microns wide –Dictated by fiber size Channels are spaced 100 microns apart Channels are spaced 100 microns apart Optical fibers to be incorporated are 250, 150, 100, and 50 microns in diameter Optical fibers to be incorporated are 250, 150, 100, and 50 microns in diameter

Mask Design Optical Fibers

Master Fabrication SU-8 is spun onto a silicon substrate SU-8 is spun onto a silicon substrate –SU is used Master is spun for 30sec at 1750rpsec Master is spun for 30sec at 1750rpsec –Gives desired thickness of 50 microns Master is then cured Master is then cured

PDMS casting and Optical Fiber Integration Three micromanipulators are used to align the optical fibers over the channels Three micromanipulators are used to align the optical fibers over the channels PDMS is poured master and optical fibers PDMS is poured master and optical fibers –Thickness can be altered each time –Placed in a vacuum to remove air bubbles PDMS is then cured PDMS is then cured –Hardness is determined by time cured –PDMS is peeled off and placed on a microscope slide

Conclusions Separately the two parts are not difficult to design Separately the two parts are not difficult to design –Initial designs for both have been agreed upon –MEMS fabrication is very simple and easily repeatable Difficulty is in the integration of the optical fibers with acceptable output signal magnitude Difficulty is in the integration of the optical fibers with acceptable output signal magnitude –Sensitivity is highly correlated to fiber size Want to use smallest fiber possible Want to use smallest fiber possible In the near future… In the near future… –Fabrication of master –Casting of initial PDMS device integrated with optical fibers –Begin testing just fluorescent die in channels If successful begin to plan for used of smaller fibers and possibly smaller channels (width) If successful begin to plan for used of smaller fibers and possibly smaller channels (width)