TFX Ultra Clamp-on Ultrasonic Flow Meter. Model TFX Ultra  Rugged, all inclusive output options  Compact integral mount system for pipes 2” (50.8 mm)

Slides:



Advertisements
Similar presentations
Emergency Transfer Controls
Advertisements

ULTRASONIC WATER AND FLOW METERS
Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Welcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
SmartVFD HVAC, BYPASS, NXL, NXS Introduction
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
You Can Measure the Benefits… Solid Applied Technologies Sewer Level Monitoring.
Zone 1 & 21 Universal Access Point Enclosure System I Copyright Extronics Ltd Zone1 & 21 Universal Access Point Enclosure System.
Competition Other types of flow meters Thermal Mass flow competition.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
PYRO-X De-Ice control devices Technical presentation 2013.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Simple, accurate tenant sub-metering
You Can Measure the Benefits… Training Course Introduction to SmartScan.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
PYROCON12 De-Ice controller User Operation Presentation 2013.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
Wireless TL70 70 mm Wireless Modular Tower Light
MIG II DIGITAL FEEDER PROTECTION
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
1 Kodak 2100 & 2200 Intraoral X-ray Systems “With the Kodak 2100 intraoral x- ray system, high frequency technology is more affordable than ever before.
SCADA and Telemetry Presented By:.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
IRRInet & ICC System Concept
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
DMC / total energy metering.pptslide 1 July 01 Daniel Measurement & Control Kyoung Su Kim.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
XMLK The ideal choice for water distribution 4…20 mA or 0….10V output M12, DIN or Metri-Pack electrical connection ¼” NPT male or G1/4 A male fluid entry.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Ultima ® X Gas Monitor with HART Display Version.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
CUE – Make Any Pump an E-Pump
Our Controllers MegaTron MegaTron Multiple System Capability Multiple System Capability Internet Communication Internet Communication Conductivity.
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
© 2011 Eaton Corporation. All rights reserved. Company Confidential This is a photographic template – your photograph should fit precisely within this.
FLATPACK Rev.5 September 2002 Updated versions may be available.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
DXN Ultrasonic Portable Flow Meter
User Operation Presentation
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
Lindab UltraLink The only thing you cannot measure is its potential
System Network Structure
FEEDER PROTECTION UNIT
De-Ice control devices
Nematron® Thin Client Hardware Launch
Nematron® Thin Client Hardware Launch
Technician Operation Presentation
Day 2 Training - Technical
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Presentation transcript:

TFX Ultra Clamp-on Ultrasonic Flow Meter

Model TFX Ultra  Rugged, all inclusive output options  Compact integral mount system for pipes 2” (50.8 mm) and smaller  Remote mount system for pipe sizes ½” (12.7 mm) and higher Integral mount shown here. Integral transducers available in PVC (standard) or optional CPVC

New generation of transit time flow meter: Increased transmit power by over 3x Compatible with ALL transducer types (do not need separate boards) USB interface to PC (for UltraLink software) Backlit LCD Easier wiring (compared with TFXL) CE mark  1% of reading accuracy Measuring range -40 – 40 FPS (-12 – 12 MPS) NEMA 4 (IP65); aluminum enclosure CSA Class I Div. 2 / ATEX II 2 G Ex nA II T4 TFX Ultra Features

Other Notable Features/Improvements:  Standard A/B USB programming connection  Field replaceable fuse (resettable on DC powered)  Optional keypad  Universal AC (95-230VAC) power option  Display backlighting  Keypad/UltraLink configure for 500 kHz, 1 MHz or 2 MHz transducers  Remote totalizer reset (via ModBUS, N.O. switch, or IP if equipped)  “GREEN” utilizes less than 5 watts (typical, 3x less than Onicon) TFX Ultra

Flow Meter Model Two Transmitter Types: Energy Model (BTU)

Outputs & Communications  Standard  Energy and Flow Meter Models  4-20mA (sourcing)  RS485 Modbus RTU Communications (2-wire)  Flow Meter Model only, also has:  Frequency Output (1000 Hz, open-collector)  Dual Alarm Outputs; high/low flow, batch, errors (open-collector)  Optional  Ethernet: Modbus TCP/IP, EtherNet/IP and BACnet/IP  Totalizing Pulse Output; isolated open-collector

TFX Ultra Optional TFXB is available with Intrinsically Safe barrier, CSA Class I Div. 1

DTTS  ½” to 2” (12 to 50 mm)  Easy/quick installation, transducers custom fit to ANSI pipe, Copper Tubing, or Rigid Tubing specs  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67)  Available in PVC for maximum fluid temperature +185 °F (+85 °C)  And CPVC for maximum fluid temperature +250 °F (+121 °C)  ½” and ¾” versions are 1% F.S. accuracy Transducer Options

DTTN  Pipe sizes 2” [50 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67); optional NEMA 6P (IP-68)  Maximum fluid temps to +250 °F (+121 °C) Transducer Options

DTTH  High Temp: maximum fluid temps to +350 °F (+176 °C)  Pipe sizes 2” [50 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67)  Includes high-temp couplant

Transducer Options DTTL*  Pipe sizes 24” [610 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67); optional NEMA 6P (IP-68)  Maximum fluid temps to +250 °F (+121 °C)  Also recommended for pipe sizes 4”-24” ( mm), if application parameters are not ideal. * Used with TFX Ultra and DXN only, 500 kHz configuration

Applications Conserve Thru Control North Adams, MA Geo Thermal Application TFX Ultras used to measure and control geo-thermal HVAC system. EPA also requires building owner to report ground water usage. Well water can carry dirt and ice which destroys inline meters.

Client: Valley Water – Plainville, CT. Municipal Water Application High velocity – no straight runs TFX Ultra replaced 901 Doppler Result: Improved accuracy Applications

P&G Gillette Beauty & Grooming Boston, MA Gillette’s sustainability project requires measurement and control of city water and process loops in 100 year old plant. Potential sale for 17 measurement points. Most lines cannot be shut down without halting production. Applications

Ulster Uniform Service Kinston, NY Industrial Laundry Since a high percentage of the water is evaporated through their dryers, Ulster uses a TFX Ultra meter to report waste water usage to save on their sewage bill. Applications

Mercedes-Benz plant, Istanbul, TURKEY Challenge: Customer dissatisfied with in-line BTU meters to measure energy use through their 15 cogeneration lines. Considered to be high maintenance and were not thought to be reliable. Solution: TFXE w/ DTTN, Clamp-on RTDs Easy installation, no process shut-down, and seamless drop-in to their Siemens SCADA system via standard Modbus RTU were seen as key advantages in selecting Dynasonics.

Genoa, Illinois WWTP Use clamp-on meters to prove output and performance of new pump; DFX Doppler and Transit time TFX Ultra both utilized, due to suspected pump cavitation. Meters showed a disparity, helped identify debris caught within the pump.

Thank you +44 (0) Bell Flow Systems are the UK representative for Badger Meter