Presentation is loading. Please wait.

Presentation is loading. Please wait.

Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS.

Similar presentations


Presentation on theme: "Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS."— Presentation transcript:

1 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation 5 reasons why SITRANS F C MASSFLO Flowmeters are among the best selling flowmeters today  High accuracy – 0.10% of mass – and repeatability ensure maximum quality and reduced waste  Multi-parameter measurement for mass flow rate, volumetric flow rate, density, fraction flow and temperature  Measurements unaffected by changes in pressure or temperature  Each flowmeter is factory calibrated before shipment  Maintenance free: no moving parts Advanced technology for increased accuracy and profitability in the Value Chain A complete line Siemens offers a complete line of highly accurate, coriolis mass flow meters for a multitude of industries and critical process applications. Thanks to their accuracy they deliver precise information about fluids or gas passing through a pipe for dosing, product blending, determining billing or cost and many other applications. Dedicated Program SITRANS F C

2 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 2 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Siemens offers a comprehensive selection of flow meters for the industry Chemical Petro-chemical Food & beverage Pharmaceutical Automotive Refining Power & utility Dedicated Program SITRANS F C MASSFLO flow meters Dedicated Program SITRANS F C

3 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 3 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation One Platform. Infinite solutions MASS 6000 IP 67/NEMA 6 MASS 6000 19” MASS 6000 19” wall mount MASS 2100 DI 3 – DI 40 MC 1 DN 50 – DN 150 MASS 6000 Exd Greater flexibility Compact or remote One type transmitter for all sizes Industry specific sensors and transmitters Flexible logistics handling Quick reaction to changing customer demands – even after ordering - delivery FC300 DN 4 Communication modules: HART Profibus PA/DP Devicenet Modbus RTU MASS 2100 DI 1.5 Dedicated Program SITRANS F C SIFLOW FC070

4 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 4 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation MASS 6000 Enhanced Signal processing MASS 6000 With MASS 6000 – Enhanced signal processing transmitters, Siemens pushes development of the coriolis technology a giant leap forward. Our technology is unaffected by variations in pressure, temperature, density, electrical conductivity and viscosity. Dedicated mass flow chip with the latest ASIC technology improves step-response and enables high-speed batching Transmitters SITRANS F C

5 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 5 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Innovative features with MASS 6000 Mass flow, volume flow, density, temperature and fraction flow are all standard measurements l gal l/s gal/sec l gal kg/s lbs/sec kg lbs kg/m 3 lbs/ft 3 °C °F  Superior noise immunity due to a patented DFT (Discrete Fourier Transformation) algorithm  Improved dynamic measurement range. Application flexibility is greatly enhanced, since the meter can be locked at any point in the installation  Advanced diagnosis and service menu enhances trouble shooting and meter verification Transmitters SITRANS F C

6 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 6 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation EXceptional safety and performance In our commitment to the chemical industry, Siemens offers industry specific solutions to help you improve asset utilization improve quality-based performance strengthen safety reduce cost of ownership MASSFLO EX Design For maximum safety and peace of mind 1. Fully stainless steel enclosure, ensuring optimum cost of ownership 2. Intrinsically safe keypad and display offer optimum functionality and programming in hazardous areas 3. Add-On Modules can be retrofitted to existing flow meters, providing communications and other functions to meet current and future demands 4. SENSORPROM technology facilitates; Factory pre- programming of calibration data. All values and settings made by the user are automatically stored 5. All Siemens sensor constructions are intrinsically safe to Ex IIC, meeting industry’s toughest challenges 1 3 4 5 2 Transmitters SITRANS F C

7 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 7 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation SIFLOW FC070 – As easy to install as playing a CD Transmitters SITRANS F C SIFLOW FC070 is a true multi-parameter coriolis mass flow transmitter suitable for all flow applications and industries, ready for quick installation – both physically and in system integration – compact and space-saving. Namur NE21 and VDE2560 CE, cULus Standard version: ATEX II 3 G EEx nA II T4 Ex version: ATEX II (1) G [EEx iA] IIC Standard version available in ultra compact 40 mm S7-300 enclosure Ex version available in compact 80 mm S7-300 enclosure

8 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 8 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Complete Range of SITRANS F C transmitters MASS 6000 19” Wall mounted MASS 6000 ExdMASS 6000 IP 67/NEMA 6 MASS 6000 19” * * MASS 6000 Exd only available with Profibus PA and HART Transmitters SITRANS F C SIFLOW FC070 Seamless integration into SIMATIC

9 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 9 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Sensors SITRANS F C Mount the clamp Fit the meter in the clamp and tighten Connect pre- wired multi- plug connector Fit back plate to converter and measurement can commence FC300 DN 4 / 1/6‘‘ Siemens has created the most compact coriolis flow meter in its class. The size and weight makes it easy to install and integrate demanding applications like e.g.: Fuel injection nozzle testing Refrigerant charging for hermetic compressors Dosing of flavorings and additives Measurement of essence and fragrances in the cosmetics industry High accuracy gas measurement – N 2, O 2, Ar, H 2, ethylene Gasoline & diesel test rigs Size: 135x205x58 mm Weight: 3.5 kg High accuracy in compact design

10 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 10 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation MASS 2100 DI 3 – DI 40 / 1/16‘‘ – 2‘‘ Optimum meter performance is achieved through an intelligent sensor design High accuracy 0.1% of rate with a large turndown ratio Self draining in horizontal installation Minimum pressure loss due to a large internal diameter throughout the entire meter 1. High immunity against changing process conditions and vibrations is achieved with unique center block concept 2. Only one pipe, with no welds. Ideal for CIP applications 3. Safe pipe design. We use the market’s thickest pipe and offer a choice of high grade stainless steel or Hastelloy for corrosive applications 4. All Siemens sensor constructions are intrinsically safe to Ex ia IIC (Zone 0), meeting industry’s toughest challenge 1 3 4 2 Meeting industry‘s toughest challenges Sensors SITRANS F C

11 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 11 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Serious performance delivers reliable results MASS 2100 DI 1.5 / 11/16‘‘ 1. The meter is installed with a single quick release clamp fitting and a single multi- plug connector that is fast and cost effective. 2. Maximum immunity to noise. The centre block concept, to- gether with balanced pipe loops, ensure dependable long-term stability eliminating influences from process conditions 3. Plug & Play. Install and commission a meter in less than 10 minutes 4. Single-pipe design optimizes hygiene and safety. All our sensors consist of one single pipe without any welds ensuring that steam or CIP cleaning can be carried out with confidence In many industries, accurate recipe control means everything. The MASS 2100 1.5 has demonstrated superior performance. It is the preferred meter for research and development and mini-plant applications for liquid or gas measurement, when measuring small quantities is important 1 3 4 2 Mount the clamp Fit the meter in the clamp and tighten Connect the pre-wired multi-plug connector Fit backplate to converter and measurement can commence Sensors SITRANS F C

12 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 12 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation Space saving sturdy design Insensitive to pipeline stresses and vibrations Self draining in both horizontal and vertical positions Rigid, solid mounting structure Optimally oriented inductive sensors generate large signal amplitudes Parallel S-tube design enhances accuracy and turndown ratio MC1 DN 40 – DN 150 / 2‘‘ – 6‘‘ Meeting industry‘s toughest challenges In the large size category, the MC1 offers the ideal fit between size, maximum flow capacity and ease of installation Sensors SITRANS F C

13 Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 13 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS F C Back to animation MASS 2100 DI 1.5 Complete Range of SITRANS F C sensors FC300 DN 4 MASS 2100 DI 3 – DI 40 MASS 2100 DN 50 – DN 150 Sensors SITRANS F C


Download ppt "Automation and Drives Siemens Flow Instruments A/S The Flow Force.pptApril 2007 1 Transmitters SITRANS F C Sensors SITRANS F C Dedicated Program SITRANS."

Similar presentations


Ads by Google