ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway

Similar presentations


Presentation on theme: "ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway"— Presentation transcript:

1 ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Connecting the field devices to Internet/intranet solution

2 What’s your problem on your SCADA & Control System
The HMI server is only your one choice !!! Does HMI server regard as a dedicated data gateway or HMI server? How much time you want to set-up this server ? You must pay double cost to maintenance server S/W or set-up redundancy HMI S/W server , HMI Server 3’rd party Controllers w/Modbus RS485/422 TCP/IP Network ( Ethernet) Operator Stations - NT/95/98 (With Modbus driver)

3 What’s your problem on your SCADA & Control System
What is your good solution for distributed control What’s your standard communication protocol & wiring for installation , implementation & maintenance standardize ? Most of field’s devices support Modbus protocol Ask our device supplier ex: PLC , DCS , RTU , power meter , recorder …..etc provide Modus I/F The cheapest solution of creating you distributed control system , SCADA , Factory automation How many operator station can access the control data concurrently ? Does any of operator station can access the any site data ? Do you want to pay about US$ to order a Ethernet card and integrated your control system into Ethernet?

4 What’s your problem on your SCADA & Control System
Where is your right place to install HMI S/W server Unmanned field site ? Waste water site? Power station site? Utility supply site ?…………etc Good air conditional operation environmental . Need a control room to install it. More money to built-up stable operating environment.

5 ADAM-4572 : Ethernet to Modbus Data Gateway
Now ,ADAM-4572 is designed as a field data Gateway ,Dedicated , Ethernet-enable & industrial grade to solve your problems It will let your field Modbus devices : Connect to Intranet/Internet Standardize distributed solution Risk-sharing Standard wiring Free maintenance Cost saving

6 ADAM-4572 : Ethernet to Modbus Data Gateway Overview
e-ADAM Modbus Solution ADAM-4572 : Ethernet to Modbus Data Gateway Overview Ethernet Port 10/100Mbps Auto-sensing S/W Function MODBus/TCP driver Auto-searching Windows Utility 8 Tasks concurrently Provide OPC server Diagnostic LED Tx/Rx Link Ok Speed status serial port status Installation Dim: Same ADAM-4000 Operating temp. : 0-60 DegC DIN-rail mounting Unregulated 10-30Vdc w/surge protection Serial Port RS232/485/422 selectable Up to 115.2Kbps Automatic data flow 5 /

7 ADAM-4572 : Key features Worldwide first release
10/100Mbps & serial port configurable Client stations HMI platform Standard Protocol : Ethernet : Modbus/TCP Serial : Modbus/RTU , ASCII Local HMI Internet Provide internet connection as data gateway for 3rd party HMI platform Local client Ethernet User App. S/W can execute on any of OS (Unix , Linux , Windows) ADAM-4572 Multi-master : max. 8 PCs can access one ADAM-4572 data through the intranet or internet concurrently RS422 RS485 ADAM-5511 PLC RS232 Meter

8 ADAM-4572 : Key features Case 1 : Configure “RS-232 “
Secret weapon Provide 3 individual serial T/B for flexible connection. Case1 : Configure RS-232 can connect one RS-232 device Case 1 : Configure “RS-232 “ Ethernet ADAM-4572 RS232 OR OR PLC ADAM-5511 Meter

9 ADAM-4572 : Key features Case 2 : Configure “RS-422 “
Secret weapon: Provide 3 individual serial T/B for flexible connection. Case2 : Configure RS-422 can connect 32 nodes RS232/422 devices( only one RS-232 device) Case 2 : Configure “RS-422 “ Ethernet ADAM-4572 RS232 RS422 Meter ADAM-5511 PLC

10 ADAM-4572 : Key features Case 3 : Configure “RS-485 “
Secret weapon: Provide 3 individual serial T/B for flexible connection. Case3 : Configure RS-4485 can connect 32 nodes RS232/422/485 devices( only one RS-232 device) Case 3 : Configure “RS-485 “ Ethernet ADAM-4572 Meter RS422 RS232 RS485 Meter PLC ADAM-5511 PLC

11 ADAM-4572 : Features Summary
ADAM-4572: Ethernet to Modbus Data Gateway Communication speed :10/100 Mbps 10 Base-T/100-Base-TX TCP,UDP,IP,ARP,Modbus/RTU, ASCII , Modbus/TCP Protocol RS-232/422/485 Serial port configurable Serial port speed up to 115.2Kbps Very easy to Install & set-up( Only 5 steps/5 minutes ) Concurrently connection up to 8 tasks Compatible with HMI S/W running on Modbus/TCP standard Provide Modbus/TCP protocol OPC server Provide automatic RS485 data flow control Unregulated 10 to 30 Vdc with power surge protection Integrate ADAM-5511 or 3’rd party devices 5 /

12 ADAM-4572 Configuration procedures: Five steps
Office Intranet Step 1: HMI & ADAM-4572 configuration S/W Wiring all ADAMs through Ethernet cable Site 6 Site 5 Site 7 Site 1 Site 2 Site 3 Site 4

13 Step 2 : Device Auto-searching & key in the description on the ADAM-4572 utility S/W

14 Step 3: IP address setting Auto-detecting Comm. Speed & mode

15 Step 4 : Serial Port Setting RS-232/422/485

16 Step 5 : MODBus Parameter Setting

17 Provide the individual wiring terminal
Installation : Modbus serial devices wiring Provide the individual wiring terminal RS-232 connection RS-422 connection RS-485 connection

18 Installation : Modbus/TCP and OPC server S/W driver
Provide free charge OPC server

19 Competition


Download ppt "ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway"