Presentation is loading. Please wait.

Presentation is loading. Please wait.

Residential Fall Protection Program Update Directorate of Construction - Office of Construction Services.

Similar presentations


Presentation on theme: "Residential Fall Protection Program Update Directorate of Construction - Office of Construction Services."— Presentation transcript:

1

2 Residential Fall Protection Program Update Directorate of Construction - Office of Construction Services

3 This presentation is intended to provide information about STD 03-11-002, Compliance Guidance for Residential Construction. The Occupational Safety and Health Act requires employers to comply with safety and health standards promulgated by OSHA or by a state with an OSHA-approved state plan. However, this presentation is not itself a standard or regulation, and it neither creates new legal obligations nor alters existing obligations created by OSHA standards or the Occupational Safety and Health Act.

4 STD 03-11-002, Compliance Guidance for Residential Construction was issued December 22, 2010. STD 03-11-002 rescinds STD 03-00-001, dated June 18, 1999, Interim Fall Protection Compliance Guidelines for Residential Construction. –All letters that reference the canceled directive will be revised or withdrawn, as appropriate. Residential Fall Protection Program Update

5 OSHA will begin enforcement activities June 16, 2011 Residential Fall Protection Program Update

6 Why the rescission? –Never intended to be a permanent resolution. –Fall protection is feasible and available. –OSHA received recommendations to rescind the interim directive. –The residential fall protection requirements have always been established in Subpart M at 29 CFR 1926.501(b)(13). The new policy directive implements the standard as originally designed. Residential Fall Protection Program Update

7 20052006200720082009 Fatalities 118612391204969816 Employment 10.7M11.3M11.4M9.5M8.3M Fatalities per 100,000 workers 11.010.910.59.69.7 Fatalities and Fatality Rates in Construction Source: BLS CFOI Data

8 “We cannot tolerate workers getting killed in residential construction when effective means are readily available to prevent those deaths.” “Fatalities from falls are the number one cause of workplace deaths in construction.” Dr. David Michaels, Assistant Secretary of Labor for OSHA Residential Fall Protection Program Update

9 The BLS Released Statistics Showing the Leading Causes of Construction Fatalities FATALITIES20052006200720082009 FALLS394433447332277 STRUCK BY13012010610879 ELECTROCUTIONS1071261088988 CAUGHT IN/BETWEEN 11196989234 Source: BLS CFOI Data

10 The BLS Released Statistics Showing the Fall Fatalities in Residential Construction FATALITIES20052006200720082009 TOTAL FALLS7162554042 FALLS FROM ROOFS 2421191117 Source: BLS CFOI Data

11 Significant Changes in the Residential Fall Protection Policy Under the new directive employers must follow 1926.501(b)(13). 1926.501(b)(13) states … “workers engaged in residential construction 6 feet (1.8m) or more above a lower levels must be protected by guardrail systems, safety net systems, or personal fall arrest systems. … or, alternative fall protection measures allowed under 1926.501(b) for particular types of work.”

12 1926.501(b)(2)(ii) - Controlled access zones and control lines can be used as alternative methods for some leading edge applications. 1926.501(b)(4)(i), and (ii) - Covers can be used as alternative methods to prevent workers from falling through holes. 1926.501(b)(5) - Positioning devices can be used as alternative methods while working on the face of formwork and reinforcing steel. 1926.501(b)(7)(i), and (ii) - Barricades, fences and covers can be used as alternative methods to prevent workers from falling into excavations. Alternative Methods Allowed Under 1926.501(b)

13 1926.501(b)(8)(i) - Equipment guards can be used as alternative methods to prevent workers from falling into dangerous equipment. 1926.501(b)(10) - A combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. All can be alternative methods while working on low-slope roofs. Alternative Methods Allowed Under 1926.501(b)

14 Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. –OSHA is not persuaded that there are significant safety or feasibility problems with the use of such equipment for the vast majority of residential construction activities. –OSHA acknowledges that there may be isolated situations in which it is infeasible or creates a greater hazard to use conventional fall protection in residential construction, but the Agency believes that 29 CFR 1926.501(13) standard requirements provide sufficient flexibility to accommodate employers in those situations 29 CFR 1926.501(b)(13)

15 OSHA did not originally define residential construction in 1926.501(b)(13). STD 03-11-002 includes an interpretation for the term “residential construction” for purposes of the standard. Significant Changes in the Residential Fall Protection Policy

16 In order to be classified as residential construction two elements must be met for purposes of 29 CFR 1926.501(b)(13). –The end-use of the structure being built must be as a home, i.e., a dwelling; and –The structure being built must be constructed using traditional wood frame construction materials and methods. The limited use of steel I-beams to help support wood framing, does not disqualify a structure from being considered residential construction. Definition of Residential Construction

17 Cold-formed metal studs will be considered within the bounds of “traditional” wood frame construction materials and methods. Residential Construction

18 The construction of residences (homes) built with wood framed and masonry brick or block walls will be considered to meet the Residential Construction Requirement Residential Construction

19 These methods will not be considered “Residential Construction” as the term is interpreted in this directive. –Precast concrete –Steel I beams beyond the use of beams used in conjunction with wood framing. –Rebar and Poured concrete when integral to the frame of the structure. Note that the construction of nursing homes, hotels and similar methods typically involves the use of these materials in the frame work of the structure and will not be considered residential construction. We may need to review some of these on a case by case basis. Non-Residential Construction

20 Workers exposed to fall hazards of 6ft. or greater must be trained to recognize potential fall hazards and in the proper installation and/or use of conventional fall protection systems. Training Requirements

21 Training must cover –How to recognize hazards. –How to minimize hazards. –How to install and/or use fall protection systems. –How to inspect systems. –Rescue procedures Supplements 1926.21 Prepare training certification. –Documentation of the latest training certification must be maintained. Retraining for changes in system/workplace and unsafe work practices. Training Requirements 1926.503

22 Guardrail Systems Safety Net Systems Personal Fall Arrest Systems Conventional Fall Protection Systems

23 Guardrail Systems 1926.502(b) Conventional Fall Protection Systems

24 Top rails 42” +/- 3” –Must withstand 200 pounds - 502(b)(3) & 502(b)(4) Mid rails halfway (at least 21 inches high) –Must withstand 150 pounds – 502(b)(5) Toe boards (minimum 3½ inches) – 502(j)(3) Surface the guardrail No steel or plastic banding Guardrail Systems 1926.502(b)

25 Guardrail Systems Here we see a 2nd floor perimeter completely protected by a guard rail system.

26 Guardrail Systems A pre-fabricated wall panel positioned for installation behind a fully protected area -- potential fall to the exterior of the structure has been eliminated. Stairwell is also protected by guard rails -- eliminating falls to the interior also.

27 Guardrail Systems Brackets for engineered guard rail systems can either be side mounted or deck mounted. Either way, all engineer systems must be installed in accordance with the manufacturer’s instruction to obtain their performance guarantee.

28 Guardrail Systems Guardrails in place during re-roofing activities.

29 Guardrail Systems This is a roofer’s and plumber’s dream … a fully guard railed roof ready to go.

30 Safety Net Systems 1926.502(c) Conventional Fall Protection Systems

31 As close as practicable, no more than 30’ below Sufficient clearance to objects below Drop tested or certified Safety Net Systems

32 Vertical distance from working level to horizontal plane of net Minimum required horizontal distance of outer edge of net from the edge of the working surface Up to 5 feet 8 feet 5 to 10 feet10 feet More than 10 feet13 feet

33 Safety Net Systems

34 Personal Fall Arrest Systems 1926.502(d) Conventional Fall Protection Systems

35 A Personal Fall Arrest System (PFAS) must include the following components: –Anchorage –Body Harness –Connector/Lanyard A PFAS may also include a lanyard, deceleration device, or lifeline. Personal Fall Arrest System

36 Anchorages used for attachment of Personal Fall Arrest equipment must be capable of supporting at least 5,000 pounds per employee attached, or must be designed and used as follows: –As part of a complete personal fall arrest system which maintains a safety factor of at least two. –Under the supervision of a qualified person. –Employer should look to the manufacturer instructions or the recommendations of a registered professional engineer for proper installation. Personal Fall Arrest System Anchor Point

37

38 Personal Fall Arrest System Full Body Harness PFAS in use during roofing and re-roofing activities.

39 4 Personal Fall Arrest System Full Body Harness A full body harness is part of a common fall arrest system used in roofing. A full body harness is designed to distribute the force of the fall throughout the body and help minimize the force of the fall. Body belts have not been allowed as part of an arrest system since January 1998.

40 5 Personal Fall Arrest System Full Body Harness The attachment point on a full body harness is a D-ring on your upper back. Be sure to use a size that fits properly. Must be used with compatible equipment.

41 Personal Fall Arrest System Full Body Harness

42 Snap hooks must be locking type. Never hook two snap hooks together unless designed for that purpose. Personal Fall Arrest System Connector/lanyard

43

44 Although the standard does not mention personal fall restraint systems, OSHA has previously stated that it accepts a properly utilized fall restraint system in lieu of a personal fall arrest system when the restraint system is rigged in such a way that restrains the worker from exposure to the fall hazard. Personal Fall Restraint System

45 Fall restraint can be a body belt or full body harness. Must be tied off so that the worker can not go past the unprotected side or edge, no matter where the work is on the walking/working surface. Gear should be adjustable to take up slack when workers move about. Personal Fall Restraint System

46 Other Work Methods Residential Fall Protection Program

47 Employers also have the option of having workers work from scaffolds (in compliance with Subpart L), ladders (in compliance with Subpart X) or aerial lifts (in compliance with 29 CFR 1926.453) instead of complying with 1926.501(b)(13). Other Work Methods

48 Platform Ladders Other Work Methods

49 Moving Scaffold Bakers / Perry Scaffolds Other Work Methods

50 Here is an example of Wall Bracket, or Top plate scaffold system. Some contractors are using these systems for rolling trusses, cutting rafter tails and hanging fascia. Other Work Methods

51 This contractor is definitely working with trusses from this Wall Bracket/Top plate scaffold system. Other Work Methods

52 The positioning of engineered guard rail system allows easy access for sheathing, roofing and utility installation. Multiple trades can be protected by these kinds of systems. Other Work Methods

53 Scaffold System Other Work Methods

54 Pump-jack Scaffold Other Work Methods

55 Extensible Boom Aerial Lift Other Work Methods

56 Extensible Boom Aerial Lift –Aerial lifts are becoming commonplace on residential construction sites. –Alternative for reaching heights if properly used. –PFAS or fall restraint must be worn and lanyard attached to basket when working from an aerial lift. Other Work Methods

57 Any system used has to help and not hinder the process. Here is a properly installed guard/hand rails using a “safety boot” system to position the uprights installed during framing. Other Work Methods

58 Here is the same system still in place through MEP installation and dry wall. Priming and painting can be done before installing the permanent handrail and removal of the guardrail. Other Work Methods

59 Working at heights cannot be eliminated, but there are ways to minimize exposure. Assemble as many parts of the building as possible on the ground. Other Work Methods

60 Flying pre-assembled structures into place will minimize worker exposure to fall hazards. Other Work Methods

61 Do as many things on the ground as possible. Here a contractor installed the building wrap as well prior to flying this section into place. Other Work Methods

62 Some contractors are even pre-positioning portions of the guardrail system on the ground. Other Work Methods

63 and flown into place. Pre-installed fall protection … what a concept Other Work Methods

64 FALL HAZARDS All sites have unprotected sides and edges, wall openings, or floor holes at some point during construction. If these sides and openings are not protected, injuries from falls can happen There’s no reason to work like this …

65 … when at minimum, you can work like this. If this worker should slip and fall, he will not hit the ground. PFAS works!

66 Some builders use 24” OC studs for non-load bearing walls Prior to installation of drywall, temporary guardrail systems (toprail, midrail, and toeboards) must be installed to prevent workers from falling through the studs

67 Like this!

68 This open-sided stairwell opening must be protected by a guardrail system (and handrail system) because there is a fall hazard of 6 feet (or more).

69 Like this!

70 If an employer can demonstrate that conventional fall protection is infeasible or presents a greater hazard, it shall develop and implement a fall protection plan. The employer bears the burden of establishing that it is appropriate to implement a fall protection plan for a particular workplace situation. Fall Protection Plan 1926.502(k)

71 The Fall Protection plan: –Must be written. –Must be site-specific. A written fall protection plan developed for repetitive use, e.g., for a particular style or model of home, will be considered site-specific with respect to a particular site only if it fully addresses all issues related to fall protection at that site. Therefore, a standardized plan will have to be reviewed, and revised as necessary, on a site by site basis. Significant Changes in the Residential Fall Protection Policy

72 Fall Protection Plan 1926.502(k) The plan must be prepared by a “qualified person” as defined by OSHA. (502(k)(1) –"Qualified Person" means one who, by possession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience, has successfully demonstrated his ability to solve or resolve problems relating to the subject matter, the work, or the project. (This could be the owner, supervisor, etc. as long as the OSHA definition of “Qualified Person” in the standard is met). Be developed specifically for the site where … residential construction work is being performed. (502(k)(1) Must be maintained up to date. (502(k)(1) All changes shall be approved a qualified person. (502(k)(2)

73 Fall Protection Plan 1926.502(k) Shall be maintained on the site. (502(k)(3) Shall be implemented under the supervision of a competent person. (502(k)(4) –“Competent Person” means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. (This could be the owner, supervisor, etc. as long as the OSHA definition of “Competent Person” in the standard is met). Shall include documentation why conventional systems are infeasible or create a greater hazard. (502(k)(5) Shall include a written discussion of the alternative work practices to be used that will eliminate or reduce the possibility of a fall. (502(k)(6)

74 Fall Protection Plan 1926.502(k) Shall identify each location where conventional systems cannot be used and designate them Controlled Access Zone (CAZ). (502(k)(7) Implement a safety monitoring system in conformance with 1926.502(h) where no other alternative measure has been implemented. (502(k)(8) Shall identify all workers authorized to work in the CAZ. (502(k)(9) Shall be reviewed and updated as appropriate if a fall, or near miss, occurs. (502(k)(10)

75 Where no other alternative measure has been implemented, the employer shall implement a safety monitoring system in conformance with 1926.502(h). The monitor must be a Competent Person as defined by OSHA –“Competent Person” means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. (This could be the owner, supervisor, etc. as long as the OSHA definition of “Competent Person” in the standard is met). Fall Protection Plan 1926.502(k)(8)

76 The competent person (Monitor): Warns workers of fall danger. Be on same working level and within visual sighting. Be close enough to be heard. Only job is to watch and warn workers. Must be easily identified. Fall Protection Plan Safety Monitor Duties

77 A sample plan is Appendix E to Subpart M and can be reviewed @ https://www.osha.gov/pls/oshaweb/owadisp.show_ document?p_table=STANDARDS&p_id=10927 Fall Protection Plan 1926.502(k)

78 In Closing All workers have a right to return safely home to their families every day. Employers must provide workers a place of employment which are free from recognized hazards. Visit the OSHA Construction webpage for additional residential fall protection compliance assistance and guidance materials. www.osha.gov/doc/residential_fall_protection.html Companies have until June 16, 2011 to come into compliance with the new directive.

79


Download ppt "Residential Fall Protection Program Update Directorate of Construction - Office of Construction Services."

Similar presentations