EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.

Slides:



Advertisements
Similar presentations
ENERGY CONVERSION ONE (Course 25741)
Advertisements

Chapter 4 Three-Phase Motors
Chapter 12 Transformers. Chapter 12 Transformers.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Chapter 12 Three Phase Circuits
6.1 INTRODUCTION TO POLYPHASE INDUCTION MACHINES
WRITTEN POLE TECHNOLOGY
Electro Mechanical System
Lesson 37 AC Generators II
Lesson 33 AC Generators.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Chapter 12 Three Phase Circuits
Three-Phase ac Voltage Generation
THREE PHASE CIRCUIT.
Three Phase Power Three Phase Motors
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Introduction to Electrical Machines
Chapter 22 Alternating-Current Circuits and Machines.
Department of Electrical and Computer Engineering
Motor ELECTRICAL ENERGY Mechanical Energy.
INTRODUCTION.
PRESENTATION ON INDUCTION MOTOR
Module G1 Electric Power Generation and Machine Controls
Motor Testing (Motor Only)
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
POWER SYSTEM PROTECTION
AC Generators (Alternators)
BALANCED THREE-PHASE CIRCUITS
Induction Motors Prepared By : PRAGNESH, MEET, SAGAR, SAAVAN, KANISH
1 ELECTRICAL CIRCUIT ET 201  Become familiar with the operation of a three phase generator and the magnitude and phase relationship.  Be able to calculate.
Induction Motors.
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Fundamentals of Electric Circuits Chapter 12
1 Motors and Generators ©Dr. B. C. Paul More Fun with Flux Mechanically Rotated Shaft Slip Rings Wires with brush contacts to slip rings Electromagnetic.
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
Understanding the                                                                                                                                                                                                                          
Chapter 13 Three-Phase Induction Motors
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
EET 306 ELECTRIC MACHINES Syafruddin Hasan.
Guided by: Sudhir pandey
Electric Machine Introduction
Chapter 6 Synchronous Motors
Motors and Generators.
ELECTRICAL TECHNOLOGY (EET 103) PN HAZIAH ABDUL HAMID.
Magnetic field due to an electric current
General power system. objective Review general energy and power system Application of fundamental knowledge of principal machines, transformer and other.
FUNDAMENTALS OF ELECTRICAL ENGINEERING [ ENT 163 ]
MUZAIDI BIN MARZUKI PPKSE.
Induction Motor (Asynchronous Motor)
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
DC Machine & Transformer
Lesson 12a: Three Phase Induction Motors
THREE-PHASE INDUCTION MOTOR
Equations, Performance, Electrical Equivalent Circuits
Electric Machine Induction Motor
Induction motor control
Three Phase Induction Motors
Energy Conversion and Transport George G. Karady & Keith Holbert
Advanced Power Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
Energy Conversion and Transport George G. Karady & Keith Holbert
UNIT II APPARATUS PROTECTION.
Agenda Introduction of Protective Relays
Utilisation of Electrical Energy
SINGLE PHASE INDUCTION MOTOR.
Equations, Performance, Electrical Equivalent Circuits
Electrical Machines (EELE 3351)
Induction Motors (Lecture 1&2)
Electric Machine Design Course
Presentation transcript:

EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3

PRESENTATION CONTENT Introduction 3-Phase System Explanation Common Causes of Imbalance Motor operation basics Effects: Electrical Power Consumption Increase Thermal Degradation of Isolation Shorting of Windings Negative Sequence Imbalance Costs Incurred Conclusion Questions

INTRODUCTION Voltage Imbalance is a very common in a 3-phase system with unequal loads. This Imbalance leads to many issues, especially with loads that are attached to all three phases. One such load is a 3-phase induction motor. Many factories utilize these lower-cost ruggedly designed machines to power different parts of their assembly lines.

INTRODUCTION CONT’D This topic is important to team 3 because we are designing a 3- phase power monitor to detect voltage imbalances and send notifications before the issues presented in this presentation arise.

3-PHASE SYSTEM In short, a three phase system is an electrical power design that can transfer three times the power by adding one more wire than our original single phase designs. By Kirov's Current law, the current that passes through an element must come back to the source. With this design, two wires would be needed. If we apply three sources to three wires but offset them by 120 degrees, the net current would result to zero. This can be seen in figure 1 below. Using this, we would no longer need a wire for the return current and by adding 1 more wire than the two-wire design, three times the power can be transmitted.

3-PHASE SYSTEM CONT’D This is the basic concept of operation for the electrical grid used by utility companies and large factories today

COMMON CAUSES OF VOLTAGE IMBALANCE Voltage imbalance can be caused by unbalanced loads while severe short- term imbalance can be caused by power system faults.

INDUCTION MOTOR BASICS When a time varying voltage is applied to a winding, a flux is created When a time varying flux is applied across rotor bars, a voltage is induced. This voltage in turn produces a current when the bars are shorted at the ends. This reaction produces a flux 90 degrees in reference to the original flux applied these actions cause the rotor to turn.

INDUCTION MOTORS CONT’D The rotor can be one of two major types: It is wound in a fashion similar to that of the stator with the terminals led to slip rings on the shaft. It is made with shorted bars. 3 phase motors are made of a combination of three stator windings. This allows a stronger and more consistant flux to be abllied to the rotor winding. This inturn produces more torgue out of the motor.

ELECTRICAL POWER Unbalanced voltages at motor terminals cause current unbalance ranging from 6-10 times the percent of voltage unbalance Voltage unbalance of 1% correlates to 6%-10% current unbalance Over current results in excessive heat, shortening the motor life Efficiency of the motor is reduced Power output remains the same while electrical power input increases due to the increase in current as well as increased resistance due to heating The increase in resistance and current stack to contribute to an exponential increase in the motor heating

CONT’D Winding losses can be calculated using I 2 R Current unbalance of 10% will increase winding losses by 21%

THERMAL DEGRADATION OF INSULATION Excessive power cause overheating of insulation Material brakes down Winding short together

WINDING SHORT CIRCUITS Excessive heat leads to winding insulation degradation which will cause windings to short together Shorted turns in stator windings often do not affect the normal operation in the early stage Types of shorts Turn-to-turn of same phase Coil-to-coil of same phase Phase-to-phase Coil-to-ground

TYPE OF SHORTS Turn-to-turn of same phase Motor might continue to operate, even though short- circuit current will flow, causing more overheating, ultimately leading to complete failure Coil-to-coil of same phase Motor might continue to operate, even though short- circuit current will flow, causing more overheating, ultimately leading to complete failure Phase-to-phase Detrimental, causes instantaneous motor shutdown Coil-to-ground Detrimental, causes instantaneous motor shutdown Turn-to-turn Phase-to-phase Coil-to-ground

NEGATIVE SEQUENCE VOLTAGE - The adverse effects of unbalanced voltages on induction motors stem from the fact that the unbalanced voltage breaks down into two opposing components that can de described using a method of symmetrical components. - Through the use of symmetrical components, we can describe an unbalanced three-phase system of voltage or current phasors using three balanced systems of phasors termed positive, negative and zero sequence.

NEGATIVE SEQUENCE VOLTAGE CONT’D - In the case of machines, motors are typically connected delta or ungrounded wye. Therefore, there would be no path to neutral for the zero components to flow. Which would result in the zero sequence components resulting to zero. Leaving us with just the positive and negative sequence.

NEGATIVE SEQUENCE VOLTAGE CONT’D - The positive sequence set consists of the balanced three-phase currents and line-to- neutral voltage supplied by the system. They are all equal in magnitude and phase, rotating at the system frequency with a phase sequence of normally a, b, c.

NEGATIVE SEQUENCE VOLTAGE CONT’D - The negative sequence set consists of the balanced three-phase currents and line-to- neutral voltage supplied by the system. They are all equal in magnitude and phase, but with opposite phase rotation.

WHAT DOES THIS MEAN FOR THE SYSTEM? Reduced net torque and speed Positive sequence voltage produces the desired positive torque, but the negative sequence voltage goes against the rotation of the rotor producing an unwanted negative torque.

WHAT DOES THIS MEAN FOR THE SYSTEM? Possibility of torque pulsations and motor noise Torque pulsations sometimes result as an effect of the unbalanced voltages on the output torque of the machine. The size of the torque pulsation is affected by the size of the negative-sequence current. Torque pulsations increase fatigue load on mechanical components and increase motor noise

WHAT DOES THIS MEAN FOR THE SYSTEM? Increased machine losses and temperatures the negative voltage sequence component will generate large negative sequence currents due to the low negative sequence impedance. This large negative current increases the machine copper losses and temperatures.

COSTS OF VOLTAGE IMBALANCE Measured rotor currents in induction motors operating with unbalanced voltages show that a 5% unbalance decreases the motor life to 30%

COST CONT’D Cage rotor induction machines account for over 80% of energy conversion in industrial and commercial sectors. The cost of a 200 HP induction motor is anywhere between $15,000 and $20,000. Industry consumed 534 Million kW in Cost of running induction motors in industry - $ 555,000,000.00

SUMMARY Three-phase systems deliver three times more power than a single-phase system. Unbalanced voltages lead to unbalanced currents 6 to 10 times greater. This increase in current causes the induction motor to heat up. The increase in heat leads to the thermal degradation of insulation. Importance to our project Troubleshooting power quality problems requires accurate measurements and our project measures all three voltages, currents, power factor, and power. Giving a time stamp to any voltage transients so that proper diagnostics can be run.