Magnum Chiller Plant Manager

Slides:



Advertisements
Similar presentations
Programming 2100 Series Controllers.
Advertisements

RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
Nano-10 based Building Automation System (BAS) Jesús BaezMarch, 2011.
Welcome to the Award Winning Easiest to Use & Most Advanced View, Manage, and Control Security, Access Control, Video, Energy & Lighting Systems, & Critical.
MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
RWD CONTROLLERS TECHNICAL
Keypad / Display Keypad/Display Mounting 6 wire shielded cable 10’ length 3 twisted pairs Keypad Three function keys Four directions.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
SV100 Open-Loop Vector VFD FV100 Closed-Loop Vector VFD 1.
CENTURION™ (C4-SERIES) Erin Cox, Market Research Analyst, Natural Gas Production Controls - Presenter Sanjay Kumar, Market Research Specialist & Product.
WebStat™ Programming and Configuration of Thermostats.
MCS-Connect Intro to Connect Connection and Setup Display Menus Graphics Uses in troubleshooting Overview.
Perform Control Test. Check for Consistent Liquid Temperatures Entering and Leaving Liquid Temperatures should be close when the water pumps are on but.
Quest Web-Browser Interface. Home Page This is the Home Page of the Quest Browser Interface. This page will show the site information, and any active.
NERC Lessons Learned Summary December NERC lessons learned published in December 2014 Three NERC lessons learned (LL) were published in December.
10 February Viewing Controller Status. 10 February Controller Status Provides a “snap shot” of the current configuration of controllers on.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
1 / 62 Internet Telephony PBX System IPX-2000(V2) SOP for the Stackable Management.
BCAL Interlock System US BCAL Chiller US BCAL MPOD 1 US BCAL PLC Pulsed Output from Flow meter to PLC From US BCAL cooling loop US BCAL MPOD 1 RS485 from.
Visit us at MicroMag Control System.
Visit us at MCS-Connect. l Windows® based (95 thru 7) l Software written in Java l Grid size dynamic and updated in place l Updated.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Introduction To Programmable Logic Controllers
Dillard’s Energy Management
CHE 185 – PROCESS CONTROL AND DYNAMICS DCS AND PLC FUNDAMENTALS.
Alternative Energy Class Room Automation Control System Lighting and Temperature Control By: Al Woodward EET-2011.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
In-Line Cell Manager Configuration and Loading Date: Octobre2014.
Configuring the MagicInfo Pro Display
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
MarsⅡ On-Line UPS Series
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
HP900 (ESP Protocol) Analogue Addressable Control Panels
Introduction to Robo Pro
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
BOSCO Architecture Derek Weitzel University of Nebraska – Lincoln.
Practical Solar Thermal Chilled Water Bud Leavell Sales Engineer Yazaki Energy Systems Inc.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
11 DISASTER RECOVERY Chapter 13. Chapter 13: DISASTER RECOVERY2 OVERVIEW  Back up server data using the Backup utility and the Ntbackup command  Restore.
ProStar 500 CVM P. van Poppel – Field Support Specialist October 2009.
TOF Gas System Project Overview. Content Prototype for Aging tests done for RPC’s TOF Gas System: parameters and module layouts. Special Technology: channel.
Click left mouse button to advance, “back” to return Phasefale November 2007 Presscon Network Click left mouse button to advance, “back” to return.
Digital Message Announcer DMA-1. Solid State Digital Audio Player Applications: security warning messages security warning messages voice alarms voice.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
MCS-MAGNUM EXV LOGIC Training Presentation Revision - 12/12/2015.
Wisdom of the Crowed Final Review High Speed Digital Systems Lab.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
MCS-Magnum Chiller Logic
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
MCS-Connect Revision - 12/22/2015.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
HYDRO MULTI-B – Pressure boosting made simple The CU323 1) Power in. 2) Internal Geni 3) Optional CIM Module 4) Analog input 5) PTC terminals 6) DI terminals.
PowerShield Battery Monitoring Systems protecting your power supply P r o t e c t i n g y o u r p o w e r s u p p l y1.
Service Section Technical Training. Sequential Controller SQ 1.0.
Central Processing Unit 0500 with ECO
Intellisys System Manager Intellisys Energy Optimizer
A transformer is a complex protective object
MCS-Magnum Chiller Logic
Product Update – Feb 2018/2019 Products Update-B - 11/12/2018.
Training Presentation
Roof Top Unit Overview (MAGNUM)
MCS-Connect Change all frames to windows
Chiller Plant Manager (CPM)
Keypad / Display Rev. J -11/21/2018.
Loop Water Controller Overview
CHAPTER – 45 RATING AND SERVICE CAPACITY
Presentation transcript:

Magnum Chiller Plant Manager www.mcscontrols.com Revision - 4/26/2017

Overview Based upon Loop Control Software-same control functions. Supports up to 8 individual loops. Control each loop independently. Communications via the RS485 port or hardwired to Magnum controllers. Provide Run/Stop and staging capacity. Provide alarm status of Magnum on the network.

Overview (Continued) Supports up to 8 individual loops. Supports up to 12 pumps or fans per loop. Supports 16 cooling/ice making and heating stages per loop. Supports 1 VFD for pumps or fans per loop with unique control sensor. Supports 1 VFD for heating stages per loop. Supports 1 VFD for cooling stages per loop.

Overview (Continued) Supports control of loops on: peak load schedules, on or off all day or based on daily schedule. Supports 2 daily schedules per loop. Supports separate run/stop and run override per loop. Supports individual set points per loop. Supports individual state names (status) per loop.

Overview (Continued) Supports up to 80 Relay Outputs. Supports up to 112 Sensors Inputs. Supports up 28 Analog Outputs. Supports 255 Set points. Supports storage of last 99 alarms. Supports 1008 History Samples for all inputs & outputs.

Chiller Plant Manager Options Individual set points for each loop. Individual loops controlled on: Run/Stop indicator. Run/Stop indicator plus temperature. Low Ambient control: None Loop off Run only pumps Enable loop to run Loop override indicator.

Chiller Plant Manager Options (Continued) Control of primary and backup pumps or fans with rotation. Schedule: Run loop on a day schedule Always on Always off On - Off schedule Do not run on peak demand hours. Separate Control Zones with ROC control logic for cooling and heating.

Pump Control Options Primary Common Each pump is directly connected to a chiller. The first pump is associated with the first chiller. The chiller will not be enabled to run unless that pump is on. If the pump fails the chiller will be turned off. Common Pumps are not associated with a chiller. Once a pump or a set of pumps are on the first chiller will be allowed to run. If a pump fails then another pump if available will be turned on.

Load Options Sequential Loading More Capacity- The first chiller will be loaded to its full capacity before the next one is enabled to run. It will then be loaded. Less Capacity- Lead chiller will be completely unloaded and run enable will be stopped. The next chiller will then be unloaded.

Load Options (Continued) Balance Loading More Capacity- All chillers will be enabled to run and will be loaded equally. Less Capacity- All chillers will be unloaded equally.

Communications Plant Manager will communicate to Magnum on the network based upon loop information. Standard class 55 messages are used for communications. Each loop can contain a starting Magnum network address and the number of Magnums. Based upon the control information for that loop, the number of steps (recips) or capacity (screws) will be determined.

Communications (Continued) Since Standard Class 55 messages are used for communications: All versions of chiller software are compatible and will accept instructions from the Plant Manager. If the Alarm RO is on, this will be communicated to the Plant Manager. No special software is required, only that the individual systems be configured to accept network input.

Alarms LOST Magnum #x ALARMonMagnum #x This alarm indicates that Magnum at address x is not communicating. ALARMonMagnum #x This alarm indicates that Magnum at address x has encountered an alarm.

For additional information please visit our website www. mcscontrols For additional information please visit our website www.mcscontrols.com Or call MCS at 239-694-0089