Continuous Benzene-Specific Monitoring Werner R. Haag & Stephen Powell Ion Science IPEC Denver 19 November 2015.

Slides:



Advertisements
Similar presentations
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
DP-IR Detecto-Pak Infrared
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
ULTRASONIC WATER AND FLOW METERS
Marketing NeSSI™ Globally What’s the Plan?. Issues There are periodic requests for NeSSI™ information from the “press” Should we provide directed mailings.
PRODUCTS for PETROCHEMISTRY Detailed Hydrocarbon Analysis of the primary petrol, refinery compounds and final products Detailed Hydrocarbon.
Gas Chromatography in the detection of Volatile Organic Compounds.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
4135 Bluebonnet Dr. Stafford, TX
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
The EX100 & EX1000 Oil in Water Monitors. The EX100/1000 Oil In Water Monitor Features 1.Continuous Flow and Accurate Measurement. 2.Measurement range.
Photoacoustic Multi-gas Monitor , page 2 Photoacoustic Multi-gas Monitor 1312 Portable monitor for quantitative analysis of up to 5 gases and.
.
American Industrial Hygiene Conference Atlanta, Georgia American Industrial Hygiene Conference Atlanta, Georgia PO135 Exposure Assessment Strategies II.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
Part 2 Direct Reading Instrumentation. Direct Reading Instruments Many different instruments Many different operating principles including: –Electrochemical.
– This document is not contractual – 07/2015 On line analysis… Industry… Oil Storage Tank… Water Draining… 1 Welcome to SERES environnement.
Oil refining and its Products
LNG Hazards.
Vincent J. Giblin, General President 1293 Airport Road Beaver, WV Phone: (304) Fax: (304) Air Monitoring.
ITX 4-Gas Detector Quick Reference Guide. Case:Type 304 Stainless Steel,.024" (.61mm) thick Dimensions:4.75" X 3.2" X 1.68" (121mm X 81mm X 43mm) Weight:18.5.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Process Analytics PSPI Flash Point Monitor Model
IT Series Gas Sensor Modules IT I nformation T echnology.
MULTI-GAS MONITOR FOR CONFINED SPACE APPLICATIONS
EESIFLO International Pte Ltd
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
HazMat Technician Mod 1 Unit 2 Slide 1 Ohio Hazmat & WMD Technician Module 1 Unit 2 Field Survey Instruments.
Safety 5120Industrial Hygiene Threshold Limit Values (TLVs) TLV ® Definition concentrations … which it is airborne concentrations … which it is believed.
Home sweet home... Or is it???? Breathing! Some basics.
WELCOME TO Gas Tester Training O2, LEL Monitoring
Infrared Camera Use for VOC Inspections.
Tools Available for Real-Time Exposure Assessment Phil Smith, PhD, CIH CDR MSC, USN
Bryan Sonnier – Project ManagerJulian Coleman – Software Engineer Jonathan Tindall – Hardware EngineerTam Bui – Test Engineer TEAM MEMBERS:
GasGard® XL Monitor.
Solution Preparation. is a solution preparation system that automatically calculates and dispenses the exact amount of solvent required to prepare a precise.
New type of Add-on Monitor for Continuous PAH Nano Particles Surface SOOT by Hans Grimm International Sales Meeting 2008.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
March 2010 Hastings Product Training Flow Products Overview.
Welcome Acklands-Grainger April 16, Technology Applications Advantage: VX500.
Continuous Particulate Monitoring Using Light Scatter Photometers.
PHOTOVAC, Inc. Voyager Gas Chromatograph Concept.
Differential Absorption Light Detection and Ranging Recent Experiences in Emissions Measurement Cary Secrest, US EPA Office of Civil Enforcement Air Enforcement.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
1 Setting Action Levels and Controlling exposure with Air Monitoring A review...
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
Sampling and Measurement for Inorganic Gaseous Pollutants.
CUE – Make Any Pump an E-Pump
1/16/2016The GC-in-a-PC 1 Pneumatic Focusing Gas Chromatography PFGC Robert O’Brien, Portland State Univ. & VOC Technologies The GC-in-a-PC Development.
Groundwater Pollution
Welcome! Please read the board carefully and get out paper for notes. Please read the board carefully and get out paper for notes.
© MSA 2015 Because every life has a purpose… Altair 5X with PID and Xtirpa Fall Protection Solutions 11/9/15 – Airgas Joe Gormley / Andy DeLair– MSA Safety.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
We use at our unit polymeric membranes to separate hydrocarbons without heating feedstock to the boiling point, and without using fired heaters.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
Microsystems for selective gas sensing
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
T. Higgs May 25, 2017 AESA Stack Testing Seminar
Jim Vermeulen MSA Territory Manager
for Compliance, Safety, Prevention
Magnetostrictive Liquid Level Transmitter
F&J SPECIALTY PRODUCTS, INC.
Gas Chromatography.
Gas Chromatography.
Total Solution for Flue Gas Analyzer Series
Automobile Emission Gas Analysis Solution
Presentation transcript:

Continuous Benzene-Specific Monitoring Werner R. Haag & Stephen Powell Ion Science IPEC Denver 19 November 2015

Benzene Industrial Exposure Oil refineries Chemical & Petrochemical Plants Offshore installations, Fracking operations Coke works Storage, distribution & use of gasoline or benzene Foundries, during casting using benzene catalysts

Benzene in Fuels Exposure Limits for Various Fuels ChemicalACGIH TWA Benzene0.5 ppm (Carcinogen) Diesel Fuel12 ppm Jet Fuel30 ppm Gasoline300 ppm

Benzene in Fuels Mixture TWA Calculation TWA total = ______________ 1 f gasoline f benzene + TWA benz ______ TWA gas.

Benzene in Gasoline

Typically 0.5 – 2% Difficult to measure selectively

Tiger Select PID/Tube can measure: No Tube: Continuous ppb levels of VOCs for screening Insert Tube: Benzene-specific readings – Single Point and 15-minute STEL

Benzene Monitoring TITAN Continuous Benzene- Specific Monitor

Benzene Specific Measurement Methods with DL near 0.5 ppm MethodTimeDLCostOther Tubes: Manual min0.5 ppm ¢ Single Point Tubes: Draeger CMS 10 min0.2 ppm ¢¢ Single Point PID w/Filter Tube1-3 min0.1 ppm$Single Point Portable GC5-10 min0.1 ppm$$Single Point Titan Separator1 min0.1 ppm$$$Continuous Portable IR<1 min2 ppm$$$Continuous GC: On-Line1 hour0.01 ppm$$$$Semi-Contin. GC: Lab Analysis1-10 days0.01 ppm$$$$Off-site Portable IMS1 min0.01 ppm$$$$Not Intr. Safe.

Control of temperature is critical therefore TITAN has two independent temperature control systems. How TITAN works Pump Sample PID Temperature control AirSep filter A large heater ensures an elevated temperature inside the main enclosure. A second heater accurately controls the temperature of the Benzene separation (Air-Sep) filter tube.

How TITAN works AirSep filter PID Valve Carbon Pump Sample TITAN continually draws a sample from the environment and through the instrument A portion of the air inside the TITAN is scrubbed by a carbon filter, and used as carrier to separate benzene & then purge the filter tube. A sample is periodically taken to be analysed for benzene content A sample is periodically taken to be analysed for benzene content

TITAN Servicing the Detector Module Benzene Sep Filter

Benzene Monitoring Titan Connectivity 2 yrs of data storage

Performance Sensor type10.6 eV PID with selective filtering Measuring gasBenzene specific Detection range0-20 ppm Measuring frequencyOnce per minuteLower limit of detection0.1 ppm Accuracy± 0.05 ppm or ± 10% ( whichever is greater)

Selectivity 100 ppm toluene 100 ppm ethylbenzene or xylene 100 ppm cyclohexane* or n-hexane** 100 ppm undecane 100 ppm gasoline 100 ppm naptha (wide cut or light) 50 ppm methyl ethyl ketone Vol % level methane** Mixture of: 10 ppm toluene, 10 ppm xylenes, 10 ppm hexane, 10 ppm cyclohexane, 10 ppm ethanol No Interference by:

The Importance of Continual Monitoring Time (Hours:Minutes) Entire events Missed by GC Sample every minute Sample every hour

The Importance of Continual Monitoring Benzene (ppm) 19 Days

Technical Specifications Hazardous approval ATEX / IECEx: Ex d II B+H2 Gb Ingress protectionIP65Humidity0-99% RH (non condensing)Minimum service periodBenzene, Carbon & Dust Filter: 6 months PID lamp & sensor grid: 1 year (-20 0 C to C) Temperature Range Weight 15 Kg

Technical specifications Communication 4-20mA RS485 Modbus half and full duplex USB (when lid removed) Relay x2 ( A max) Power Data storageON board MMC minimum 2 yearsSample flow200 ml/minGas sample line10 meters (optional)

The End Thank you (0) (0)