Presentation is loading. Please wait.

Presentation is loading. Please wait.

Total Solution for Flue Gas Analyzer Series

Similar presentations


Presentation on theme: "Total Solution for Flue Gas Analyzer Series"— Presentation transcript:

1 Total Solution for Flue Gas Analyzer Series

2 Technologies & Strengths

3 NDIR Dual Beam Technology
Based on dual beam design which one is reference channel and another one is test channel, our sensors always get reference to make immediate self-adjustment to ensure the high performance.

4 Micro-flow NDIR Technology
Dual gas chamber design innovatively, one gas cell is injected measurement gas, another one is filled with reference gas N2, then micro-flow infrared sensor output the signal change, comparison between measured gas variation and reference gas signal to get the precise measurement result.

5 UV-DOAS Technology Light source: Xenon flash lamp.
Gas chamber: Long optical path reflection gas chamber. Spectrometer: UV-band spectral response is fast, measurement accuracy is high, resolution is good.

6 Technology Benefits Micro-flow NDIR UV DOAS
Best choice for measuring SO2, NO, CO ≥ 500ppm Best choice for measuring SO2, N0 ≤ 500ppm, dual range H2S Water adjustment device to eliminate the impact of on measurement Unaffected by moisture and environmental temperature Integrated temperature controller to reduce environmental temperature affect Drift is less during ultra-low range measurement Less drift & stable performance Minor vibration impact

7 Product Presentation

8 Flue Gas Analyzer Series
Online Flue Gas Analyzer Portable Flue Gas Analyzer Continuous Monitoring System hot hot hot Gasboard-3800Plus Gasboard-3000Plus hot hot Gasboard-9050 Gasboard-9081 Gasboard-90850 Gasboard-3000 Gasboard-3800P Gasboard-3800UV Gasboard-3000UV

9 Online Flue Gas Analyzer Series
Gasboard-3000 Micro-flow NDIR sensor with single gas chamber design 3 IR sensors + ECD sensor (4 sensors at most) Gasboard-3000Plus Micro-flow NDIR sensor with dual gas chambers design Gasboard-3000UV UV DOAS sensor 2 UV sensors + ECD sensor

10 Online Flue Gas Analyzer
Model Gasboard-3000Plus Gasboard-3000UV Technology Micro-flow NDIR UV DOAS Measurement Min Range Max Range Standard Range SO2 0-200ppm 0-5000ppm 0-100mg/m³ NO CO / CO2 0-5% 0-25% O2 Accuracy SO2, NO, CO, CO2: 2%FS SO2, NO: 2%FS Repeatability ≤1%FS

11 Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH
Performance Test Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH Test Item Gasboard-3000Plus Gasboard-3000UV Chinese Test Standard SO2: 0-500mg/m³ NO: 0-500mg/m³ SO2: 0-100mg/m³ NO: 0-100mg/m³ Test Result Response Time T90 < 40s T90 < 29s JJF Linear Error ±1.33%FS ±1%FS HJ/T Repeatability ≤0.15% ≤0.14% HJ/T Zero Drift / week ±1.4%FS ±1.3%FS HJ/T Span Drift / week

12 Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH
Interference Gas Test Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH Model Gasboard-3000Plus (SO2, NO: 0-500mg/m³ ) Interference Gas Gases 1st Test (mg/m³) 2nd Test (mg/m³) 3rd Test Average Value Influence Value N2-100% SO2 8 6 7 NO 5 CO-305mg/m³ 2 3 -0.87% 4 -0.27% CO2-15% 0.07% 10 1.00% CH4-50mg/m³ 9 0.60% 0.00% NH3-20mg/m³ 15 14 1.60% Interference gas influence: ±1.60% FS

13 Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH
Interference Gas Test Test environment: Indoor temperature: 25±10℃ Humidity: <85% RH Model Gasboard-3000UV (SO2, NO: 0-100mg/m³ ) Interference Gas Gases 1st Test (mg/m³) 2nd Test (mg/m³) 3rd Test Average Value Influence Value N2-100% SO2 -0.5 -0.6 NO -0.8 -0.4 0.1 CO-305mg/m³ 0.2 0.0 0.50% 0.5 0.4 0.3 0.70% CO2-15% 0.7 0.87% CH4-50mg/m³ 0.90% 0.6 0.8 1.00% NH3-20mg/m³ 1.2 1.1 1.0 1.57% 0.73% H2S-30ppm 0.9 1.47% 0.93% Interference gas influence: ±1.57% FS

14 New Sensor Bench - For Easy Intergration Purpose
UV DOAS NDIR

15 Micro-flow NDIR and UV DOAS Sensor Bench
Sensor bench solution for SO2, NO, CO measurement. Suitable for integrate into complete instrument.

16 New UV DOAS Sensor Bench
UV DOAS working principle Flashing xenon lamp acts as light source Long-path reflection gas chamber Stable supply voltage and current Strong absorption signal Flexible test range available which can less than 200mg/ m3 with high precision Stable performance, No cross interference between the measurement of gas Modular design, simple structure, small size, easy integration & maintenance Long life time, cost effective Gasboard-2006 Series H2S,NO & NO2 ,SO2 H2S NO,NO2 SO2

17 New NDIR Sensor Bench Gasboard-2000 Series CH4 CO NO SO2
NDIR working principle Stable and reliable infrared light source Stable power supply voltage & current to reduce signal interference Higher stability & high measurement accuracy Test range can be customized Compact appearance with modular design for easy integration & maintenance Long life time, affordable price Gasboard-2000 Series CH4, CO & NO,SO2 CH4 CO NO SO2

18 Portable Flue Gas Analyzer Series
Model Gasboard-3800P Gasboard-3800Plus / Gasboard-3800UV Instrument Pre-treatment device

19 Portable Flue Gas Analyzer
Model Gasboard-3800P Gasboard-3800Plus Gasboard-3800UV Technology Micro-flow NDIR UV DOAS, NDIR Measurement SO2 0-2000ppm 0-2000mg/m³ mg/m³ NO mg/m³ (optional NO2) CO 0-5000ppm 0-5000mg/m³ mg/m³ (optional HC) CO2 0-25% O2 Gas conditioning device Self-produce Europe Brand Sampling probe Heating tube Chinese Brand Total weight 60 Kgs 45 Kgs

20 Continuous Emission Monitoring System- Gasboard 9050

21 Continuous Emission Monitoring System-Gasboard 9050
Extract sample gas directly in different temperature level. Heating tube to avoid measurement gases loss. Gas cooler to remove the moisture and keep sample gas dry. Micro-flow NDIR and UV DOAS instruments are provided in the most of projects.

22 Continuous Boiler Emission Monitoring System-Gasboard 9081
System Cabinet Sampling Parts Pre-treatment Parts

23 Ship CEMS-Gasboard 9085 Technology: NDUV+ NDIR+ECD Features
Measurement: SO2, NO, CO, CO2, HC, O2 Features Cyclic monitoring of multiple sampling points. Suitable for environments with vibration, high temperature and humidity. Auto Zero & span calibration. 7-inch touch screen. Data stored for up to 1 year. Support RS-232, RS-485, 4-20mA output. Optional sound and light alarm output.

24 Project Reference

25 Project Reference 1) A.O Smith 2) University usage 3) Customer design

26 Project Reference

27 Project Reference Customer: Power plant in Indonesia.
Application: Pollution emission monitoring, SO2, NO, CO, CO2, O2, TPF and dust.

28 Project Reference Customer: Cement plant in China.
Application: Measurement CO concentration to ensure process safety in production.

29 Project Reference CEMS project in different industrial applications in China

30 Project Reference Power Plant Application in China

31 Project Reference 1) Cement project. 2) CEMS installation guide.
3) Project in Pakistan. 4) Sampling probe installation.

32 Hubei Cubic-Ruiyi Instrument Co., Ltd
Add:Fenghuang No.3 Road, Fenghuang Industrial Park Eastlake Hi-tech Development Zone Wuhan , Hubei Province, China Tel: / Fax: Web:


Download ppt "Total Solution for Flue Gas Analyzer Series"

Similar presentations


Ads by Google