Medium Voltage Outdoor Apparatus Portfolio

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Medium-Voltage Switchgear - Then and Now -
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
© Southwest Electrical Distribution Exchange (SWEDE) May 2, 2008 Materials and Equipment John Macek Application Director, S&C Electric.
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
OHB Outdoor sulphur Hexafluoride circuit-Breaker
1 Distributed Generation and Power Quality. 2 Relaying considerations DG infeed may reduce the reach of overcurrent relays –DG feeds fault, so utility.
Rep Training Presentation. The Focus Today Who we are targeting…Who is a typical Trayer customer Who we are targeting…Who is a typical Trayer customer.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
INTRODUCTION TO SWITCHGEARS
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
CIRCUIT BREAKER.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Multi-function apparatus for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Medium Voltage Switchgear
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Chapter 7 SYSTEM PROTECTION
INSULATION COORDINATION COURSE ELEC. ENG. DEPT. SHARIF U. of T. MEHDI VAKILIAN MAY 2009.
By R. Vijay Krishna. CONTENTS  INTRODUCTION  WORKING PRINCIPLE OF C.B  TYPES OF CIRCUIT BREAKERS  SF6 CIRCUIT BREAKER.
Pole Mounted Switch Disconnector NPS
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
Distribution Automation Overview, Activities, and Roadmap David G
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
Transformer Taking the ratio of the two equations
SARDAR PATEL INSTITUTE OF
© ABB PTMV - 1, ABB Overhead Distribution Systems.
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
SF6 load break fault make switches for overhead networks
Utility Engineers, PC.  Generation  Transmission  Distribution.
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
© ABB - Page 1 OVR-1: Single Phase Recloser Customer Presentation February 2006 ABB Lake Mary, Florida.
Submitted to: Submitted by:
Air Blast Circuit Breaker
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Disconnector Switches and Earth Switches
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
ECE 498HZ: Power Distribution System Analysis
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Permanent Solutions to Temporary Loads: An Alternate Approach to Electrical System Design for Short Term and Mobile Industrial Loading Presented by: Eli.
AUTOMATIC CIRCUIT RECLOSER
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Sub Station.
SUB-STATIONS.
Overhead Distribution Systems
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
Name, department/event, date
Circuit Breakers & Reclosers
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
High Voltage Power Circuit Breakers
Oil-tight MV fuse CEF-OT with TPC bushings
ELECTRICAL POWER-II Electrical engineering sixth semester
EHV Transmission Equipments
Presented by: Marco A Garcia, P.E.
SWITCH GEAR AND PROTECTION(IV-1) TOPIC-CIRCUIT BREAKER
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Its strengths, your benefits
Substation Equipment's
Presentation transcript:

Medium Voltage Outdoor Apparatus Portfolio July 2004 Brian Johnson

Typical Overhead Distribution System 1PH Switch - 1 Ph Manual OR Fuse OR Cutout Switch - 1 Ph Manual Cutout OR 1 Ph Sectionalizer Capacitor Switch 3PH 3 Ph Sectionalizer Line Recloser Breaker / Recloser Reconfiguration Switch - Manual - Automated Switch - Manual - Automated 3PH 3PH

PTMV Outdoor Apparatus Portfolio Outdoor Circuit Breakers Reclosers Automated Sectionalizers Sealed Switches Air Switches Fused Cutouts Not in portfolio, today: Voltage Regulators Insulators, Cables, Hardware

Outdoor Circuit Breakers Type R 15-27 kV ANSI Type R-Mag 15-27 kV ANSI & IEC Type V 38 kV ANSI Dead Tank Type SDB 12 12 kV IEC Live Tank Type OHB 24-36 kV IEC

Type R Dead Tank Circuit Breaker Vacuum Interruption Spring Operated Mechanism ANSI C37.06 – 1997 Dead tank design reduces cost of CTs and installation Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 15 – 27 kV 600 – 3,000 A 12 – 25 kA

Type R-Magnetic Dead Tank Circuit Breaker Vacuum Interruption Magnetic Actuator Mechanism reduces maintenance costs and concerns ANSI C37.06 – 1997 & IEC 56 Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 15 – 27 kV 600 – 3,000 A 12 – 25 kA

Type V Dead Tank Circuit Breaker Vacuum Interruption Spring Operated Mechanism 150 or 200 kV BIL High capacitor switching ratings to use to protect and switch substation capacitor banks Redundant vacuum bottle ANSI C37.06 – 1997 Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 38 kV 1,200 – 2,000 A 25 – 40 kA

Type SDB 12 Live Tank Circuit Breaker Vacuum Interruption Spring Operated Mechanism or Magnetic Actuator Drive IEC Manufactured ABB, India Voltage Rated Continuous Current Interrupting Current 12 kV 630 – 1,600 A 18.4 – 26.3 kA

Type OHB Live Tank Circuit Breaker SF6 Interruption Spring Operated Mechanism IEC Manufactured ABB, India Voltage Rated Continuous Current Interrupting Current 24 – 36 kV 2,500 A 31.5 kA

Automated Reclosers and Sectionalizers OVS – 3 Phase Sectionalizer 15-38 kV ANSI & IEC OVR – 3 Phase Recloser 15-38 kV ANSI & IEC Autolink – 1 Phase Sectionalizer 12-38 kV IEC OVR – 1 Phase Recloser 15-38 kV ANSI & IEC

OVR Three Phase Automated Recloser Embedded Vacuum Interrupters in Solid Dielectric (no oil, nor SF6 to maintain) Magnetic Actuators Pole or Substation Mounting Programmable PCD Control to automate system protection – loop schemes, automatic alternate settings ANSI C37.60+90 – 1997 Manufactured ABB, USA 12 – 16 kA 560 – 800 A 15 – 38 kV Interrupting Current Rated Continuous Current Voltage

OVR Single Phase Automated Recloser Ratings: 15 – 38 kV 630 / 800 Amp Up to 170 kV BIL 12.5 kA Compact, lightweight HCEP Insulation Material Superior life – rated for 10,000 operations 2nd Generation Magnetic Actuators Environmentally friendly – no oil or gas ANSI C37.60+90 – 1997 Manufactured ABB, USA

OVS Three Phase Automated Sectionalizer Embedded Vacuum Interrupters in Solid Dielectric Magnetic Actuators Pole or Substation Mounting Simple Sectionalizing Control ANSI & IEC Manufactured ABB, USA 16 – 20 kA 630 A 15 – 38 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Autolink Single Phase Sectionalizer Single Phase Automatic Sectionalizer Specialty device to reduce nuisance tripping problems Magnetic Actuation to eliminate fuse replacement costs IEC Manufactured ABB T&D Ltd, Australia Voltage Rated Continuous Current Interrupting Current Actuating Current 12 – 36 kV 250 A 6 kA 5 – 224 A

Sealed Contact, Loadbreak Switches OVS 15-38 kV ANSI & IEC Sectos NXBD 12-24 kV IEC Sectos NXA 38 kV ANSI & IEC Sectos NXB 12-24 kV IEC

OVS Automated Switch Embedded Vacuum Interrupters in Solid Dielectric Magnetic Actuators ISD or PCD Control for simple applications or sophisticated automation schemes ANSI & IEC Manufactured ABB Inc., USA Development project to add visible break 10,000 loadbreak operations SCADA Ready – integrated current sensing, voltage sensing on frame, control cabinet space and power for customer communications 16 – 20 kA 630 A 15 – 38 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Sectos NXA Switch Disconnector Two-position Load Break-Fault Make Switch Disconnector Single or Double Spring Mechanism Manual (Hook stick) or Integrated Motor Operated Shipped complete, Simple to install SF6 insulation IEC (General Purpose Type) & ANSI Manufactured ABB, China 12.5 kA Short Time Withstand Current 3 Sec. Sym 630 A 36 kV (38 kV ANSI) Rated Continuous Current Voltage

Sectos NXB Switch Disconnector Two or Three-position Load Break-Fault Make Switch Disconnector Single or Double Spring Mechanism Manual (Hook stick) or Integrated Motor Operated Shipped complete, Simple to install Available in single phase for special applications SF6 insulation IEC (General Purpose Type) Manufactured ABB, China 20 kA Short Time Withstand Current 3 Sec. Sym 630 A 12 – 24 kV Rated Continuous Current Voltage

Sectos NXBD Switch Disconnector Two Switches in Same Housing Two Switched Ways and One Tapped Way Two or Three-Position Load Break-Fault Make Switches Disconnector Single or Double Spring Mechanism Manual Operation by Hook Stick Shipped complete, Simple to install SF6 Insulation IEC (General Purpose Type) Manufactured ABB, China 20 kA Short Time Withstand Current 3 Sec. Sym 630 A 12 – 24 kV Rated Continuous Current Voltage

Three Phase Air Switch Disconnects NPS 12-36 kV IEC Series ‘U’ 12-36 kV IEC Series ‘R’ 12-36 kV IEC

NPS Switch Disconnector Vertical and Horizontal Break Vertical and Horizontal Pole-Mounted Optional Load Break and Load Make Control Units (DTU) available IEC (Limited Purpose Type) Manufactured ABB, Finland Easy to localize, if desired Up to 16 kA 630 A 12 – 24 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Series ‘R’ Disconnect Switch Vertical Break Horizontal & Vertical Pole Mounted Optional Load Break IEC Manufactured ABB, Australia Up to 31.5 kA 800 – 2000 A 12 – 36 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Series ‘U’ Disconnect Switch Side Break Horizontal & Vertical Pole Mounted Optional Load Break IEC Manufactured ABB, Australia 20 kA 630 A 12 – 36 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Single Phase Air Switch Disconnects Series ‘SLSB’ 12-24 kV IEC RBD & SLDT – Recloser Bypass Switch 15-36 kV ANSI & IEC Series ‘SLD’ & DCD 12-36 kV IEC & ANSI SID, LSID & SLS 12-38 kV NEMA, ANSI & IEC ITD – Inline Disconnect 15-36 kV ANSI

Series ‘SLD’ & ‘DCD’ Disconnect Switches SLD/DCD: Single Phase Double Insulator SLD/DCD: Horizontal & Vertical Pole Mounted SLD – IEC; DCD - ANSI SLD - Manufactured ABB, Australia DCD - Manufactured ABB, USA 16 – 25 kA 630 – 900 A 12 – 36 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

ITD Disconnect Switches ITD: Inline Tension Single Phase Disconnect Installs directly into the distribution line ANSI Standards ITD - Manufactured ABB, USA 200kV BIL insulation to limit flashovers 16 – 25 kA 600 – 900 A 12 – 36 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

SID, LSID, SLS Disconnect Switches SID & SLS: Single Phase LSID: Single Phase Load Break SID & LSID: NEMA & ANSI SLS: IEC SID & LSID: Manufactured ABB, USA SLS: Manufactured ABB, Australia Good design for narrow installations and riser pole installations 16 – 40 kA 600 – 900 A 12 – 38 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Series RBD & ‘SLDT’ Bypass Switches RBD/SLDT: Single Phase Bypass Switch RBD/SLDT: Horizontal & Vertical Pole Mounted Main application – bypassing reclosers and voltage regulators to perform maintenance SLDT – IEC; RBD - ANSI SLDT - Manufactured ABB, Australia RBD - Manufactured ABB, USA 16 – 25 kA 630 – 900 A 12 – 36 kV Short Time Withstand Current 3 Sec. Sym Rated Continuous Current Voltage

Rated Continuous Current Series ‘SLSB’ Single Phase By-Pass Disconnector Integrated Fused Cutout for fault protection IEC Manufactured ABB, Australia Voltage Rated Continuous Current Interrupting Current 12 – 24 kV 630 A 25 kA

Fused Cutouts Type LBU-II Type ICX Type NCX Type EU & EUH Series ‘V’ Most complete portfolio in the world! Type LBU-II 7.8-34.5 kV NEMA & ANSI Type ICX 7.8-38 kV NEMA & ANSI Type NCX 7.8-38 kV NEMA & ANSI Type EU & EUH 2.6-7.8 kV NEMA & ANSI Series ‘V’ 12-36 kV IEC

Rated Continuous Current Type NCX Fused Cutout NEMA & ANSI Manufactured ABB, USA Dual-venting to reach higher interrupting ratings Voltage Rated Continuous Current Interrupting Current 7.8 – 38 kV 100 – 300 A 2 – 20 kA

Rated Continuous Current Type ICX Fused Cutout Interchangeable Fuse Tube (with S & C, Chance, Cooper) Moisture Proof Fuse Tube reduces swelling over time NEMA & ANSI Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 7.8 – 38 kV 100 – 300 A 8 – 16 kA

Type LBU-II Fused Cutout Integrated Load Break Device to loadbreak safer, simpler and without special tools NEMA & ANSI Manufactured ABB, USA Voltage Rated Continuous Current Interrupting Current 7.8 – 34.5 kV 100 – 300 A 6 – 20 kA

Series ‘V’ Fused Cutout Single & Three Phase IEC Manufactured ABB, Australia Voltage Rated Continuous Current Interrupting Current 12 – 36 kV 100 A 2 – 8 kA

Rated Continuous Current Type EU and EUH Enclosed Cutouts Specialty cutout normally used in indoor and grid applications Dropout or Non-dropout NEMA & ANSI Manufactured ABB, USA Only major producer in the world Voltage Rated Continuous Current Interrupting Current 2.6 – 7.8 kV 100 – 200 A 4 – 20 kA