GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.

Slides:



Advertisements
Similar presentations
Add Doors to Open Multi-deck Cases: Provisional UES RTF Meeting August 30,
Advertisements

UPDATE ON GROCERSMART 4.0 RESEARCH PLAN Regional Technical Forum May 3, 2011.
GrocerSmart 4.0 redesign -request for rtf input- February 25, 2010.
GrocerSmart TM Energy Modeling Software -Revision Status Report- Jeremy Litow, Associate Director David Murphy, Program Manager June 1, 2010.
BPA Guidelines for Measurement & Verification of Energy Efficiency Measures Presented at Brown Bag Session November 29, 2006.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Evaluation of Energy Savings for Strip Curtains Presented To RTF Scott Moore PECI Sr. Engineer June 2, 2009.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Floating Head Pressure for Refrigeration Single Compressor Systems Michele Friedrich, PE – Sr. Engineer Dustin Bailey – Engineer PECI 11/2/2010.
Rachel Weaver Program Manager Maryland Energy Administration
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
Today’s “Game Plan” Two Trial-Runs of a new deemed measure review process – Deemed measure analysis and review Developed by … – (consultant, RTF member/staff,
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.
DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC_3 Quality Maintenance 1 Research Plan.
Advanced Power Strips (APS) Planning UES Measure Proposal Regional Technical Forum August 20, 2013.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
HPWH UES Measure Initial Review 16 April Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N BPA Energy Efficiency Preliminary Strategies for BPA Evaluations March 24, 2008.
Guidelines for the Development and Maintenance of RTF- Approved Measure Savings Estimates December 7, 2010 Regional Technical Forum Presented by: Michael.
Residential Behavior Programs RTF Subcommittee Ryan Firestone September 17, 2015.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
EnergySmart Grocer Program Evaluation Findings Summary PWP, Inc.
GrocerSmart™ 4.0 RTF Subcommittee Approval of Adherence to Guidelines March 10, 2011.
Reviewing the Audit Results. Defining a Quality Base Year is Key to Maximizing Project Value n Base year is the mutually agreed upon pre-retrofit annual.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Strip Curtains for Refrigerated Walk-in Boxes Michele Friedrich, PE – Sr. Engineer Eric Mullendore – Energy Analyst PECI 8/3/2010.
RTF Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Refrigerator Decommissioning: Measure Status Update Regional Technical Forum October 16, 2013.
RTF Staff, Subcommittee and Work Updates November 1, 2011.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE March 18 th, 2015 Residential New Construction Standard Protocol Subcommittee Kick-off.
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
RTU Measure Preparation for Review as Standard Protocol Staff Request for Authorization of RFP Funding from the Regional Technical Forum 28 June 2011.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
EER Analysis Results Regional Technical Forum March 18, 2014.
New Refrigeration Measures - FHP Status Report- & -Request for Input- September 21, 2010.
RTF Custom Protocols: Background, Issues and Critical Elements February 8, 2012 Regional Technical Forum Subcommittee on Impact Evaluation and Custom Protocol.
EnergySmart Grocer. 2 BPA background  The Bonneville Power Administration contracted Cascade Energy Engineering, Inc. to evaluate the GrocerSmart audit.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
High Efficiency Evaporator Coils for Medium Temperature Cases Dustin Bailey, Engineer PECI Jan 5, 2010.
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
Grocery Store Issues RTF April 10, Need Recommendations PECI: Energy Smart Grocer Program Savings method for interactive measures Savings method.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum July 15, 2014.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
GrocerSmart TM Energy Modeling Software -Revision Status Report- & -Request For Input- July 13, 2010.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Exterior LED Area Lights
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
1 How good are building simulation models? Comparing simulated and actual building energy consumption at the circuit level Brock Glasgo, PhD Student Engineering.
Prof. Chris Hendrickson
Presentation transcript:

GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011

2 Topics: Today’s Decisions GrocerSmart 4 Purpose and Timeline Documentation Field Protocol Result Validation Plan for Calibration

Today’s Decisions RTF approval of the documentation strategy Baseline calibration for GS4 provisional protocol status Feedback on measure savings calibration approach, plan and timeline –What is the RTF recommended “best practice” approach Discussion of potential field application guidelines as process to keep simulation model on bounds during the calibration process

Purpose and Timeline

Refresher on Purpose Increase audit information gathered with fewer assumptions Perform site-specific calculations Capture interactivity Offer programs measure complexity

GS4 History with RTF

Documentation Approach reviewed and approved by RTF Refrigeration Subcommittee

8 DOE2 Baseline Energy DOE2 Proposed Energy Template Code Envelope HVAC auto-sized Lighting W/SF Equipment W/SF Standard Values Audit Code Fixtures Walk-Ins Compressors Condensers Schedules Measure Code Keyword Changes

Audit

Template

Measures

Field Protocol

Field Staff Training Refrigeration schedule review Auditing best practices Complete visual glossary of equipment likely to be seen in field Full EMS training with mock system Full audit walk through with senior field staff

Within Acceptable Ranges? SIM Param EUI Space Temps Measures Savings Audit Calcs Complete Recommendations to customer based on historic savings averages Examine cause of out-of-bound results. Apply the following as necessary: Adjustments to Template, Audit-generated, or Measure BDL code Field staff training Audit Process Calculated Savings Accepted Where necessary, recommended calculator changes to RTF subcommittee for approval PECI Field Staff PECI Engineering Staff Yes No

Validation

16 Validation....Calibration Calculator Validation –Confirms energy calcs are within reasonable range –Reasonable range defined by GS3 historical data CBSA –Building level and system level Results Validation –Similar to Calculator Validation –Done for every audit Calibration –Confirms energy calcs closely match that of best method Site specific Compared to recorded data –Continuous Improvement

17 TestingPilot Roll Out In Market Calculator Validation Template adjustment Baseline energy validation System level calibration Audit Data Template adjustment Measure adjustment Per Audit Result validation Continuous Improvement Measure level calibration Time Operational Parameters Check Acceptable Ranges of Energy Savings Now

18 Operational Parameters 1. Building Level 2. System Level Validation Question: Is the modeled building functioning in an expected way? Source: Parameter: Energy Use Index (EUI) CBSA – Northwest Commercial Stock Assessment

19 Operational Parameters 1. Building Level 2. System Level Validation Question: Are building systems operating at expected levels as modeled? Sources: Parameters: Normalized refrigeration energy use in kWh/BTU Sales floor temperature Simulation Reports

Example Measure Savings Ranges From Historic GrocerSmart 3.0 Calculated Savings Acceptable Savings Ranges

Validation of GrocerSmart 4.0 Tests Acceptable Savings Ranges

Calibration

23 Potential Best Practice Methods for Savings Calibration PROS CONS Whole Building Data availability (compared to end use) Savings estimated from actual usage Estimates include non-refrigeration activities/changes Calibration approach unclear Measure Isolation Savings estimated from end use level usage Builds end use data for region Estimates do not capture interactions with other systems Cost Calibrated Simulation Data availability Difficult to align with template approach Difficult to implement

Savings Calculator Calibration Plan 1.Annual / monthly comparison of calculated energy use to billing data Reality check to see if our template is producing a reasonable whole-building baseline approximation of energy use. 2. Refrigeration subsystem calibration kWh/MBH of system, for different configurations 3. Metered energy savings by measure High Impact Measures (HIM) Metering with measure isolation

1.Annual / monthly comparison of calculated energy use to survey data Reality check to see if our template is producing a reasonable whole-building baseline approximation of energy use. RTF/Subcommittee discussion points: Number of tests Level of calibration Valid data sources Schedule

26 Possible Sources: Meter refrigeration subsystems Lights, fan motors, anti-sweat heaters, compressors and condenser fan motors. Meter data from measurements (field not lab) reported in literature (e.g. Summit Blue program evaluation, PNNL LED case lighting), from store monitoring system (compressors) and from PECI measurements. 2. Refrigeration subsystem calibration kWh/MBH of system, for different configurations RTF/Subcommittee discussion points: Number of tests Level of calibration Valid data sources Schedule

Baseline Refrigeration Calibration Variables Matrix Variables Affecting AccuracySource(s) of Value Calibration Variables Refrigerated case conduction Case libraryX Refrigerated case infiltration Case libraryX Walk-in infiltration Audit driven estimateX Walk-in design capacity Audit driven estimateX Walk-in latent heat ratio TemplateX Walk-in occupancy and schedule TemplateX Walk-in equipment loads TemplateX Saturated suction temperature throttle TemplateX EPR valve pressure drop TemplateX Saturated condensing temperature throttle TemplateX Backflood valve setpoint TemplateX Design TDs for condenser sizing Condenser libraryX OA temperature Weather fileX

3. Metered energy savings by measure High Impact Measures (HIM) Metering with measure isolation Outline 2 year schedule 5-10 sites per measure Northwest High Impact Measures > 50% of program kWh Stratification of samples: tons of refrigeration per square foot Measurement Approach: Use building interval meter data from 1 year prior to and 3 months post installation. Calculate error of GS compared to best method for all measures and all sites. Examine trends in error data to determine root cause. Modify GS inputs to reduce error to 20% for all sites and HIM measures.

Measure Calibration Variables Matrix Example: FHP Control Variables Affecting AccuracySource(s) of Value Calibration Variables Baseline condenser fan control Audit input Baseline minimum set point Audit input Number and size of condenser fans Audit input, library Condenser type: air-cooled or evap-cooled Audit input Condensing unit or remote condenser Audit input Condenser over-sizing Audit input, library Fan control for measure EEM keywords Condenser fan VSD Audit driven estimateX Total hours above and below new and old minimum set point Weather file Refrigeration load during floating hours - case load Audit input, libraryX Refrigeration load during floating hours - walk-in load Audit driven estimateX Refrigeration load during floating hours - store humidity and temperature Weather file, template for HVAC X Compressor capacity control (multiplex, unloaders, VFD) Audit input

30 Provisional Approval: Documentation Result Validation Plan for Calibration