Hardware Training Product: ITMS2.

Slides:



Advertisements
Similar presentations
Remote Monitoring and Control System
Advertisements

HARDWARE Rashedul Hasan..
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Supervisory Control & Data Acquisition DAQ Networking.
ZXM10 EISU Training.
SV100 Open-Loop Vector VFD FV100 Closed-Loop Vector VFD 1.
Total HVAC Control from anywhere Easy control that can save a fortune
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
GS3055-I GSM Universal Wireless Alarm Communicator
MDR-304 Digital Video Recorder. Can do: - Reliable real time recording of vehicle interiors & surrounding road environment. - Removable recorder unit.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
PXL-500/-510 Tiger Controller II
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
SYMAP-BC SYMAP-BC.
Remote Monitoring and Management Solutions ®
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Dry type transformers Zaragoza Accessories and options
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
AVT2000D is a portable and compact in size magnetic installation vehicle tracking device which is easy in mounting and hiding to where there is the metal.
HDVR Ch Hybrid Digital Video Recorder Copyright © PLANET Technology Corporation. All rights reserved.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
The Vision of a Leader Rapid Eye Plus Technical Training.
Signal Conditioning & I/O By: YH Goh Technical Evangelist RLC AP.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
12-/24-Port Gigabit IEEE 802.3at High Power Injector Hub HPOE-1200G HPOE-2400G.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
XS26-2 Expandable Safety Controller.
IND131/331 Process Weighing Terminal. Internal usage only 1 Process Terminal Portfolio - Opportunity  Process Prices Performance IND110 IND560 IND780.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access
THE NEXT step towards a greener footprint for your NETWORK
1 | INALA TECHNOLOGIES ECS-L TESTING : VERSION 1.0.
Inala technologies site infrastructure management
NFS System Components & Installation.
1 | INALA TECHNOLOGIES INSTALLATION TRAINING: ECS (EQUIPMENT COMMUNICATIONS SYSTEM) ECS (ETH/GPRS) COMMISSIONING VERSION 1.0.
INAlA TECHNOLOGIEs Installation Training:
INAlA TECHNOLOGIEs Installation Training:
INAlA TECHNOLOGIEs Installation Training:
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
1 | INALA TECHNOLOGIES TEST PROCEDURE: ECS2, SAM2, SAM1.5 & ACCESS VERSION 1.0.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the CON-DVT-IOE. Intellect 1.5 is used for the software portion. NEXT.
New product introduction:
PRESENTATION. Parts of the PCOS (3) Operator LCD Screen with Counter (4) Printer Compartment (5) Transmission Port (9) “RETURN” Button (8) “CAST” Button.
DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Introduction to IP Cameras Over Coax. Replacing Analog Cameras With IP Cameras Over Coax Analog Camera RG59U Coaxial Cable 18/2 Power Cable Low Voltage.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
FLATPACK Rev.5 September 2002 Updated versions may be available.
ORDERING INFORMATION PART NUMBER DESCRIPTION OPTICAL PWR BUDGET MAX DISTANCE (Option) PRODUCT SPECIFICATION EL – 8V2202 TX / RX LINK DIGITAL VIDEO 8CH.
Poseidon 4002 Rack monitoring.
System Network Structure
A transformer is a complex protective object
Analog Room Command Module
【Date: 】
Building a 2 KW SSPA for 23cm
Presentation transcript:

Hardware Training Product: ITMS2

INDEX ITMS: Network System Diagram. Mechanical Presentation of ITMS. Unit Capacity. SAM2 ITMS (IP Controller) ITMS System Components Installation Connections WWW.INALA.CO.ZA

WWW.INALA.CO.ZA Harware ITMS2

NETWORK SYSTEM DIAGRAM WWW.INALA.CO.ZA

MECHANICAL PRESENTATION A – SAM2 Main Controller Unit B – Alarm Input Adaptor C – Pix Alarm Output Adaptor D – Utility Interface Module E – GSM Modem F – LCD and Key pad G – E1 Controller Unit H – Access Control Unit ECS2 unit is 2u High and 300mm deep and fits into a 19” Transmission Rack WWW.INALA.CO.ZA

UNIT CAPACITY – SAM2 SAM2 : SAM2 Main Controller 26 x General Purpose Digital inputs 4 x Generator #1 Digital Inputs 4 x Generator #2 Digital Inputs 4 x Aircon Digital Inputs 6 x Temp Analog Inputs 1 x Analog Input 0-60vdc 1 x Analog Input 0-20mA 3 x Relay outputs – Generator Ctrl 4 x Aircon Drive Outputs 24 x Pix Outputs (RBS) 1 x DC Fan Output, Speed Ctrl 1 x RS485 Port – communication to E1 Controller Expansion Modules Available: 1 x GSM Modem 1 x Generator Controller (2 x Gen Sets) 2 x Fuel Management (RS485) 1 x Battery Management (RS485) 1 x Utility Management (RS485) 1 x HEM (Hybrid Extension Module) WWW.INALA.CO.ZA DC Ventilation Fan

UNIT CAPACITY – ITMS Remote Management Modules Available: IP Communication Controller: 1 x RS232 Port – Unit Configuration Port 2 x TCP/IP Ports 1 x RS485 Port - Communication to SAM2 and Access Control Unit 2 x RS232 Port – Virtual Port 1 x Relay – Lock Failsafe Override Expansion Modules Available: SP8 - 8 x RS232 port SP6 – 6 x RS232 port & 2 x RS485 Port LAN Card - 4 x TCP/IP Ports WWW.INALA.CO.ZA ITMS Controller SP6 - PCB DC Ventilation Fan SP8 - PCB

SYSTEM COMPONENTS Wiring Kit Main Control Unit Aircon Control Switch WWW.INALA.CO.ZA Wiring Kit Main Control Unit Aircon Control Switch Smoke Room Temp & Humidity AC Mains Phase Frequency Monitor Door Switch Movement Battery Current Probe Hybrid Extension Module

DVR COMPONENTS Video Surveillance 4 Channel DVR Indoor IR Dome Camera WWW.INALA.CO.ZA 4 Channel DVR Indoor IR Dome Camera Video Surveillance TCP-IP Remotely managed DVR Four channel CCTV DVR Eight channel CCTV DVR CCTV Indoor dome type cameras CCTV Outdoor bullet type cameras Indoor TCP-IP Web Cam 4 Channel DVR

WWW.INALA.CO.ZA Installation ITMS Components

ITMS2 – RACK MOUNT UNIT WWW.INALA.CO.ZA Alarm Input Module ITMS2 Unit

DOOR SWITCH WWW.INALA.CO.ZA Door Switch

MOVEMENT SENSOR WWW.INALA.CO.ZA Movement Sensor

SMOKE SENSOR WWW.INALA.CO.ZA Smoke Sensor

ROOM TEMP & HUMDITY SENSOR WWW.INALA.CO.ZA Room Temp & Humidity Sensor

AC MAINS PHASE MONITOR WWW.INALA.CO.ZA AC Main Phase Frequency Monitor

HYBRID EXTENSION MODULE WWW.INALA.CO.ZA Hybrid Extension Module

BATTERY CURRENT CLAMP 200A Probe 500A Probe Wire Lead WWW.INALA.CO.ZA 200A Probe 500A Probe Wire Lead Probe Termination Blue GND Not Connected Orange Positive (+) White/Orange Negative (-) White/Blue Battery Current Clamp 500A Battery Current Clamp 200A

Aircon Control Switch – Clipon Type WWW.INALA.CO.ZA Aircon Control Switch To Second Aircon

Aircon Control Switch – Pearl Type WWW.INALA.CO.ZA Aircon Control Switch

Rectifier – Alarm wiring WWW.INALA.CO.ZA

AC Mains & Generator on load Alarm WWW.INALA.CO.ZA

Surge Protection Alarm WWW.INALA.CO.ZA

Over/Under AC Voltage (Eskom) Alarm WWW.INALA.CO.ZA Blue

Over/Under AC Voltage (Eskom) Alarm WWW.INALA.CO.ZA

Over/Under AC Voltage (Eskom) Alarm WWW.INALA.CO.ZA

ITMS RS485 COMMS WIRING WWW.INALA.CO.ZA

WWW.INALA.CO.ZA SOFTWARE ITMS

SAM2 ECT SAM2 ECT: Current Version ECT – V2.17 ECT Version is viewed on the top left corner as indicated with the yellow circle EG: “AIU 2 ECT V2.17” Current Version Firmware – V2.17 Firmware Version is viewed on the top left corner as indicated with the Red circle EG: “AIU Version: SAM205 V2.17” Front Panel View: Room and Aircon Vent temps and run times Alarm Input Status Output Status # The “Front Panel” is a real-time information panel display WWW.INALA.CO.ZA

ITMS ECT (IP Controller) IP Controller (V2.1 - 2 Lan Port) ECT: Current Version ECT – V2.12 ECT Version is viewed on the top left corner as indicated with the yellow circle EG: “ITMS-C Ver 2.1.2” Current Version Firmware – V3.0.0.9 Firmware Version is viewed on the button left corner as indicated with the Red circle EG: “S/W: 3.0.0.9” WWW.INALA.CO.ZA

THANK YOU