HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.

Slides:



Advertisements
Similar presentations
Cabling system components
Advertisements

Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza.
Telecommunication Rooms
Residential Telecommunications Infrastructure Standard
Chapter 3: Planning a Network Upgrade
1 Structured Backbone Design of Computer Networks.
Network Engineering Taster Day Mark Clements. 30 March 2012Engineering Taster Day 2 Welcome to Engineering Taster Day: Morning Session Ambassadors Fire.
Cabling Structured Cabling Standards
CHAPTER Practical Token Ring Implementation. Chapter Objectives Give an overview of the Token Ring LAN Describe the characteristics of the Token Ring.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Physical and Network Topology Security
TIA-1005 (Proposed by TR-42.9) Industrial Cabling Standard Pete Lockhart Anixter Manufacturing IT Forum Cleveland, Ohio May 20-21, 2008.
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Physical Media Now that we’ve been over how to encode data as signals, what are the physical media that carry these signals?
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Structured Cabling Overview
Copyright CCNA 1 Chapter 6, Part 1 Ethernet Technologies By Your Name.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Innovative Ways To Make Cost Effective LANs for K-12 Schools
Installing the Network Chapter 11 Release 16/7/2009.
1 PBX installation considerations BASIC TELECOMMUNICATIONS.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
OBJECTIVES 1. Define horizontal cabling. 2. Describe backbone cabling.
Hardware Concepts Chapter 4.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
How does AC line noise create problems?
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
Signamax Structured Cabling Seminar. INTRODUCTION.
1 Guide to Network Cabling Fundamentals Chapter 5.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
CABLING SYSTEM BACKBONE SUBSYSTEM.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Networking and Health Information Exchange Unit 2b Network Media and Hardware Communication Devices Component 9/Unit 2b1 Health IT Workforce Curriculum.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Jim Van Dyke Network Engineering & Technology Section The UCAR Physical Network Infrastructure or Why Bother to Do It Right? Presented By: James R. Van.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
Design and Documentation Chapter 8. Network Design Issues Your first step in the process is to gather information about the organization. This information.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Gary Marret, RCDD WHAT IS ETHERNET? WHAT IS ETHERNET? WHAT IS ETHERNET/IP? WHAT IS ETHERNET/IP? ETHERNET HARDWARE? ETHERNET HARDWARE? HOW DO I CABLE.
COPPER AND FIBER REVIEW
BACKBONE SUBSYSTEM. CABLING SYSTEM Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers.
TELECOMMUNICATIONS SPACES. WORK AREA WA Work Area Work Area (WA) Telecommunications Outlet (TO) Horizontal subsystem cables Equipment and patch cords.
TELECOMMUNICATIONS SPACES
Ipswich City Precinct. 6. ICC Precinct Installation Standards & Regulatory Compliance ICT Infrastructure Integration & Convergence 1. Pit & Pipe Underground.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
NETWORKING MEDIA b Shielded twisted-pair - 2 pair, 150 ohm b unshielded-twisted pair - 4 pair, 100 ohm b fiber optic cable - 2 fibers b coaxial cable -
Physical Network Design. Phiysical Network Design Selecting Technologies and Devices for – Campus Networks – Entreprise Network.
GIGANET SMART BUILDING SOLUTIONS.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Data centre network map
Copper-Based System Residential Cabling Topologies & Standards 8
INTRODUCTION TO NETWORK CABLING
Structured cabling What, why & how.
Ch 7 Fiber Optics Technician’s Manual, 3rd. Ed Jim Hayes
Horizontal and Back Bone Cabling
Wired and Wireless Troubleshooting
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Lecture 3 LAN Transmission Media
Presentation transcript:

HORIZONTAL SUBSYSTEM

CABLING SYSTEM

Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from the Work Area Telecommunications Outlet to the Horizontal Cross-connect in the Telecommunications Room

Horizontal Subsystem The Horizontal cabling subsystem consists of –Horizontal subsystem cables –Telecommunications Outlet in the Work Area –connecting hardware at the Horizontal Cross-connect (interconnect or cross-connect) –any cross-connections to application specific equipment at the Horizontal Cross-connect –Consolidation Point (optional) –Multi-user Telecommunications Outlet (optional)

Topology  1 The Horizontal cabling subsystem shall have a star topology. All Work Area Telecommunications Outlets must be connected with the Horizontal Cross-connect in the Telecommunications Room by means of a cable TO CP WA TR HC

Topology  1 It is recommended that the Telecommunications Room be located on the same floor as the Work Area it serves

Topology  2 Work Areas shall be served by the Horizontal Cross- connect located in the Telecommunications Room on the same or adjacent floor

Topology

Horizontal Cross-connect Two ways of connecting active equipment to the Horizontal cabling subsystem and one method for passive connection between the Horizontal and Backbone subsystems are used in the Horizontal Cross-connect: –Interconnection and –Cross-connection

Distances The Horizontal subsystem distance is the cable length from the mechanical termination of the media at the Horizontal Cross-connect in the Telecommunications Room to the Telecommunications Outlet in the Work Area

Distances  14 Maximum cable length (distance) in the Horizontal cabling subsystem shall be no more than 90 m (295 ft) regardless of the type of transmission media

Distances  15 The total length of twisted-pair equipment and patch cords used in the Horizontal Cross-connect to make cross-connections, interconnections, and connection of active equipment shall not be more than 5 m (16 ft) – for 24-AWG cords 4 m (13 ft) – for 26-AWG cords

Distances  16 The total length of optical fiber equipment and patch cords used in the Horizontal Cross-connect to make cross-connections, interconnections, and connection of active equipment shall be based on the maximum allowable distance (including the Horizontal subsystem cable and Work Area equipment cable) limited by the specifications of anticipated telecommunications applications

Distances  17 The length of the twisted-pair equipment cord used to connect active equipment in the Work Area to the Telecommunications Outlet shall not be more than 5 m (16 ft) – for 24-AWG cords 4 m (13 ft) – for 26-AWG cords

Distances  18 The length of the optical fiber equipment cord used to connect active equipment in the Work Area to the Telecommunications Outlet shall be based on the maximum allowable distance (including the Horizontal subsystem cable, equipment and patch cords used in the Horizontal Cross-connect to make cross- connections, interconnections, and connection of active equipment) limited by the specifications of anticipated telecommunications applications

Distances  19 The total length of the twisted-pair Horizontal subsystem cable, Work Area equipment cord, equipment and patch cords used in the Horizontal Cross-connect shall not be more than 100 m (328 ft)  20 The total length of the optical fiber Horizontal subsystem cable, Work Area equipment cord, equipment and patch cords used in the Horizontal Cross-connect shall be limited by the specifications of anticipated telecommunications applications

Transmission Media The following types of transmission media are allowed in the Horizontal cabling subsystem of the Signamax Cabling System: –category 5e, 6, and 6a four-pair 100-Ohm unscreened twisted- pair cables –category 5e, 6, and 6a four-pair 100-Ohm screened twisted-pair cables –62.5/125 µm optical fiber multimode cables (OM1) –50/125 µm optical fiber multimode cables (OM2, OM3, OM4) –9/125 µm optical fiber singlemode cables (OS1, OS2)

Configuration  21 All Signamax Cabling System Work Areas shall be built based on at least two Telecommunications Outlets serviced by two Horizontal cabling subsystem cables: Outlet/connector 1: Connecting hardware, 4-pair twisted-pair cable with category 5e, 6 or 6A transmission performance Outlet/connector 2: Connecting hardware, 4-pair twisted-pair cable with category 5е, 6 or 6A transmission performance, or Multimode optical fiber connecting hardware, 2-fiber cable, or Singlemode connecting hardware, 2-fiber cable

OPEN OFFICE CABLING

MuTOA Example of Multiuser Telecommunications Outlet Assembly application:

Consolidation Point Example of Consolidation Point application:

TELECOMMUNICATIONS PATHWAYS AND SPACES

Pathways and Spaces Horizontal subsystem pathways are facilities for the installation of telecommunications cable from the Telecommunications Room to the Work Area Telecommunications Outlet. Horizontal pathways encompass: –Underfloor pathways –Access floor –Conduit –Tray and wireway –Ceiling pathways –Perimeter pathways –Furniture pathways

Pathways and Spaces  47 All pathways where the Horizontal subsystem cables are installed shall be intended for this purpose and shall not share their space with other services of the building  49 The Horizontal distribution system pathways shall be designed and installed in compliance with local and federal construction regulations and electrical safety codes